| 1 | Cleaning/clearing of chocked sewage lines of any depth by removing any type of blockage from sewage drain pipes up to and including 150mm dia to 300mm dia by rodding or any other means from manholes to manholes or from trap and flusing with water after cleaning. Sludge/sludge water to be disposed off through septic tank & soakage well/pits and sludge in form of semi solid/loose state & it will be disposed off out side the Defence land (the rate for digging & closing of pit with soilis including in the rates) including taking off manhole covers and re fixing the same after cleaning. Sewage lines cleared/cleaned under this item is to be maintained and kept fully functional by removing any type of blockage. (a) The sewage lines and all the manholes shall be maintained in functional state through out the year i.e 11 Months from the date of cleaning of sewage line. |
| 2 | M&L for cleaning of spot blockage & refix of floor trap, nahani trap, gully trap, urinal out let trap, WC (Indian or EWC),WHB, Sink outlet by removing the CP or PVC grating and CI oval access door etc of any type including cleaning of sludge & removing to out side of MD Accn Or OTM complete or cleaning and removing of spot blockage by any means in between trap and up to Ist manhole of any size and depth , removing of sludge or any other foreign materials out side of the Defence land and it including cutting/clearing away grass vegetation , saplings, shrubs ,brushwood ,undergrowth ,roots compelet all around of manholes upto a distance 1.2m & along pipe lines both sides upto a distance 2m , compelet all as specified and directed .Note: 02 Labours for cleaning of manholes/nahani trap/ gully trap manually Or way of any other suitable means ,will report to AGE B/R-I complain cell at 0845 hrs daily except sunday & holiday, failing which the recovery @ 500/day per person will imposed to the contractor as the clearing of sewage blockage is an essential work. |
| 3 | Pumping out sewage water from septic tank & soak well where required by Sewer Suction Machine as directed with taking precautionary measures including tools & plants as required and removal of sludge and other foreign materials out side of the Defence land Waste shall be dumped in excavated dump pits and shall be disinfected using bleaching powder Or waste Deposited damp to nearest STP of Cantonment or Other Department (working in foul condition) complete all as specified directed. |
| 4 | Cleaning and de sludging of manholes of up to 1.5 mtr depth including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means, including and dispose off sludge and other foreign materials out side of the Defence land and re fixing of man hole covers etc (working in foul condition) complete all as specified & directed. |
| 5 | Cleaning and de sledging of manholes exc 1.5 mtr but n.exc 3 mtr depth including taking out sludge in any form alongwith all other foreign materials by Sewer Suction Machine and dispose off sludge and other foreign materials out side of the Defence land and re fixing of man hole covers etc complete (working in foul condition) complete all as specified & directed.Note: Item which measured in item No 4 shall not be mesured in this item. |
| 6 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed. |
| 7 | All as per Item No 6 above but exc 1.5M and n.exc 3M deep complete all as specified & directed. |
| 8 | Returning, filling in, including spreading, leveling, watering and well ramming in layer n.exc 25 cm thick in each layer complete all as specified & directed. |
| 9 | Removing of surplus soil excavated materials to a distance exceeding 50 M but not exc 100M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and hunching for 150mm bore of pipe complete all as specified and directed. |
| 11 | All as per Item No 10 above but 200 mm dia complete all as specified and directed. |
| 12 | M&L for 150 mm dia DW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed. |
| 13 | All as per Item No 12 above but 200 mm dia complete all as specified and directed. |
| 14 | M&L for reinforced concrete pipe of 150 mm bore, class NP 2 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed. |
| 15 | All as per Item No 14 above but 200 mm dia complete all as specified and directed. |
| 16 | M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed |
| 17 | Description all as per Item No 16 above but 200 mm dia complete all as specified and directed. |
| 18 | Cutting into existing manholes for connecting new drains making good to pipes and rendering, cutting out existing benching for and forming, branch channel( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finish and reforming benching as required for 150 mm dia SWG pipe complete all as specified and directed. |
| 19 | Description all as per Item No 18 here in before but 200 mm bore of pipe complete all as specified and directed. |
| 20 | M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed. |
| 21 | M&L for providing pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover for manholes and drains including necessary form work set in CM 1:4 complete all as specified and directed.(Note :- Reinforcement shall be measured and paid separately) |
| 22 | S&F TMT bars 10 mm dia and above cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 23 | M&L for Reinforced cement concrete Nominal mix Type B0 1:2:4 (12.5mm graded aggregate)in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 24 | Formwork to soffits of suspended slab such as roof slab, floor slab, wall and landing and similar work, not exc 200 mm thickness (hori zontal or sloping) with rough finished surfaces of concrete complete all as specified and directed. |
| 25 | Demolition of brick work built in cement or cement lime mortar incl all quoins, arches, pillars etc, complete all as specified & directed |
| 26 | M&L for brick work with sub class ‘B’ brick, straight curved on plan exc 6m mean radius built in cm (1:4) using old size bricks complete all as specified and directed. |
| 27 | M&L for brick work with sub class ‘B’ brick, in one brick thick honey comb walling built in cm (1:6) using old size bricks complete all as specified and directed. |
| 28 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed. |
| 29 | M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound @ 200ml per 50 Kg of cement finished even and smooth without using extra cement complete all as specified and as directed.Note: water proofing compound shall be measured and paid seprately. |
| 30 | Supply only liquid water proofing compound complete all as specified and directed. |
| 31 | S&F in repairs 10litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe and PVC connections 15mm size with PTMT nuts of length 450mm inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed . |
| 32 | S&F in repairs vitreous china wash down water closet pan pedestal pattern including seat cover white excluding flushing cistern and flush pipe complete all as specified and directed. |
| 33 | S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, along with integral foot rests including cast iron Trap 'P' or 'S' 100 mm dia, flush pipe, lime concrete bedding inlcuding taking out of old WC pan, old lime concrete bedding, unserviceable connections etc connecting up new and making good disturbe portion complete all as specified and directed. |
| 34 | S&F in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, waste coupling, incl fancy type CP pillar tap complete all as specified & directed. |
| 35 | S&F in repair 32 mm bore/40mm PVC pipe as in waste pipes for sinks & WHBs, complete all as specified and directed. |
| 36 | S&F in repairs plastic wc seat cover and mild steel chromium plated or aluminised hinging device etc complete all as specified and directed. |
| 37 | S&F in repairs Flushing jet (health faucet) for pedestal pattern WC incl. flexible pipe and Brass Chcomium Plated nuts and blots and water pipe of size 1150 mm long between dia & fixed complete all as specified and drected. |
| 38 | Dismantling floor, hearth wall tiling including cement mortar bedding (but not backing) including rubbish off the premises complete all as specified and directed. |
| 39 | M&L for non skid ceramic coloured tiles (squre/ rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6.complete all as specified and directed. |
| 40 | M&L for glazed ceramic coloured tiles of size 450x350x7mm thick fixed over and including 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected. |
| 41 | S&F in repair PVC (SWR)pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed . |
| 42 | S&F in repair PVC (SWR)pipes 110mm dia single socketed in any length with rubber ring joints fixed on wall etc complete all as specified and directed . |
| 43 | S&F in repair PVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed . |
| 44 | S&F in repair PVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints fixed on wall etc complete all as specified and directed . |
| 45 | S&F in repairs PVC (SWR) bends any radius 110mm dia complete all as speified and directed |
| 46 | S&F in repairs PVC (SWR) bends any radius 75mm dia complete all as speified and directed |
| 47 | S&F in repairs for fixing in repair 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed. |
| 48 | S&F in repair 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed. |
| 49 | S&F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. Please Enable Macros to View BoQ information |