Tender For Repair/Replacement Of Rusted Steel Tubular Pole/Pcc Pole And Repair/Replacement Of Lt Cable And Other Connected Work At Inside/Outside Pocket Area At Af Station Gwalior
Tender Overview
Project Description
Tender for Repair/Replacement Of Rusted Steel Tubular Pole/Pcc Pole And Repair/Replacement Of Lt Cable And Other Connected Work At Inside/Outside Pocket Area At Af Station Gwalior
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Jul-2026 | 8589/E8 | Date | 22-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and taking down old existing rusted/de-shaped/worn out LT/HT steel tubular pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed. |
| 2 | Dismantling and taking down old existing rusted/de-shaped/worn out LT/HT PCC pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed. |
| 3 | Supply and erecting steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole complete all as specified and dircetd. Make:- Jindal Steel Products /Bombay Tubes and Poles /National Tubing Co. /BCW. |
| 4 | Supply & errect in position steel tubular pole complete with MS base plate finial taper plug, cap bolt, nut screws etc all as specified regarding swaged pole of type 410 SP-55 11 mtrs long incl painting with one coat of red oxide paint and there after two coats of aluminium paint and black bitumen paint on hidden surface in foundation of structure of approved make/quality complete all as specified and directed. |
| 5 | M & L for jointing and testing for provision of straight through joints, Heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for following sizes 70 to 95 Sqmm 3.5 core complete all as specified and directed. (Make : M Seal/Denson/Mahindra Chemical/3M, REPL) |
| 6 | -Ditto- but 150 Sqmm to 185 Sqmm 3 1/2 core |
| 7 | M&L for PCC (1:3:6 ) type C-2 ( using 40 mm graded stone aggregates ) as in sub base foundation etc. complete all as specified and directed. |
| 8 | M&L for PCC (1:2:4 ) type B-1 with20 mm graded stone aggregates for coping of poles finished surface even smooth with all necessary form work complete all as specified and directed. |
| 9 | M&L for PCC (1:4:8 ) type D-2 with 40 mm graded stone aggregates for foundation of pole of complete all as specified and directed. |
| 10 | M&L for surface excavation over the areas in any type of soil around the poles/feeder pillar boxes/ Panels/ sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation complete remove of roots any type and levelling incl removal of surplus soil upto 50 m distance complete all as specified and directed. |
| 11 | Supply the hard core broken stone/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, to a true surface at the places complete all as specified and directed. |
| 12 | M&L for complete removing/scraping the existing pre-painted 9 mtrs/11 mtrs long existing LT/HT pole and M&L for preparing surface for applying new paint with two coats of approved quality aluminium paint with existing accessories such and clamp channel, angles etc. M&L for numbering of poles with white paint on black back ground as per the directions and providing three Nos of reflector strips of 15 CM width over the pole surface on height of 1.50 mtr from GL in Red, Yellow, Green colours complete all as specified and directed. |
| 13 | Supply and installation & Testing factory made CPRI approved LT feeder pillar box of size 60cmX45cmX30cm for 3 phase, 4 wire, 415Volt, AC, 50Hz, outdoor, cubical type, weather, dust and vermin proof, pedestal mounting type suitable for front operated applications having aluminium bus bar rating capacity 600Amps and neutral 400 Amps rating capacity mounting of insulators, incoming controlled with fixed type MCCB 3 Pole of capacity 400 Amps and breaking capacity Icu= 36KA including canopy on top and gland provision in bottom made out of 3.15mm thick MS sheet duly powder coated of approved shade using 40mmX40mmX6mm angle iron frame and suppots and leg not less than 90 cm (45 cm embeded in PCC) including necessary excavation and grouting work in PCC 1:2:4 mix, type B1 complete all as specified and directed. |
| 14 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. |
| 15 | Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed. |
| 16 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting pointcomplete all as specified and directed. |
| 17 | Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note : Punned thickness shall be measured and paid. |
| 18 | Supplying & Laying Sub Class `B’ common burnt bricks old size as in cable protection complete all as specified and directed. |
| 19 | Laying only old retrieved serviceable bricks/cable covers for cable protection as obtained from dismantling of the existing cable complete all as specified and directed. |
| 20 | Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any type and in any position complete including taking down protection pipe and seviceable bricks/ cable covers and stack up at the site properly complete all as specified and directed for the following sizes: |
| 21 | 16 Sqmm to 50 Sqmm any core |
| 22 | 95 Sqmm to 120 Sqmm 3½ core |
| 23 | 150 Sqmm to 185 Sqmm 3½ core |
| 24 | 240 Sqmm to 300 sqmm 3½ core |
| 25 | Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed for the following sizes: |
| 26 | 16 Sqmm 4 core |
| 27 | 50 Sqmm 3.5 core |
| 28 | 95 Sqmm 3.5 core |
| 29 | 120 Sqmm 3.5 core |
| 30 | 150 Sqmm 3.5 core |
| 31 | 185 Sqmm 3.5 core |
| 32 | 240 Sqmm 3.5 core |
| 33 | 300 Sqmm 3.5 core |
| 34 | S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 150 to 300 sqmm XLPE insulated armoured aluminium conductor cablecomplete all as specified and directed. |
| 35 | Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 50 mtr etc complete all as specified and directed. |
| 36 | Boring of holes under road, pavement, hard standing by mannual borring and including insertion of GI pipe upto mm dia complet all as specified and directed.Note : GI pipe will be paid separately under respective items of schedule |
| 37 | M & L in repair rusted pipe & jointing GI water tubing, 40 mm bore,light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed. |
| 38 | All as item 25 but GI tubing 80 mm bore. |
| 39 | All as item 25 but GI tubing 100 mm bore. |
| 40 | S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 Street light luminair with high power LED as light source 100 W LED 4000K with1.5 sqmm 3 core copper conductor cable complete including dismantling and taking down old unserviceable street ligt/flood ligh fitting any type/size/capacity and specification complete all as specified and directed. |
| 41 | S&F On load change over switch, four pole with advance neutral 630 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing panel location including taking out existing unserviceable change over switch complete all as specified and directed. |
| 42 | Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed. Please Enable Macros to View BoQ information |
| 43 | Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender