| 1 | Excavation in trenches not exc. 1.5 mtr wide and depth not exc. 1.5 mtr for foundation, laying GI pipes and UG cables etc not exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed. |
| 2 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Supply and laying 50 mm outside dia double wall corrugated pipe (DWC pipes SN-8) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. |
| 5 | Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 6 | Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 sqmm 4 core including taking down old unserviceable cable and making necessery connections all as specified and as directed. |
| 7 | All as item no 6.00 but of size of cable 16 sqmm 4 core |
| 8 | All as item no 6.00 but of size of cable 10 sqmm 4 core |
| 9 | All as item no 6.00 but of size of cable 10 sqmm 2 core |
| 10 | Taking out old servicable tilted poles and refixing same at location as directed by engineer-in-charge including excavtion for taking out complete all as directed.Note:- PCC for foundation and coping work shall be measured and paid separately under respective items. |
| 11 | Supply and fixing Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31 (9 metre long) including taking down old unserviceable RCC pole complete all as specified and directed. |
| 12 | Supply and fix MS adopter for street light fitting of existing size and shape with nut bolts inclusive of one primer coat , one finished coat of aluminium paint all as specified and as directed. |
| 13 | Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint heat shrink type, complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately) |
| 14 | Materials and labour for PCC, type C1, (1:3:6), using 20mm graded crushed stone aggregated, as in foundation of poles, panels etc. with necessary formwork including demolition of old damaged concrete from pole complete all as specified and as directed |
| 15 | Materials and labour for PCC, type B1, (1:2:4), using 20mm graded crushed stone aggregated, as in coping of poles including formwork including demolition of old damaged concrete from pole complete all as specified and as directed |
| 16 | Materials and labour PCC, type D2, (1:4:8), using 40mm graded crushed stone aggregated, as in PCC on road cutting /installation area and foundation of pole etc complete all as specified and as directed. |
| 17 | Materials and labour for boring holes for 100mm dia pipe upto 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items). |
| 18 | Supply and fixing in repair LED 25 W warm white colour building security light made up of pressure die cast housing with high efficient LED as lighting source and toughned glass cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia 40 mm complete all as specified and directed. |
| 19 | Supply and fixing in repair LED street light of capacity 100 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded toughned glass including electronic driver should have luminaire efficacy ≥140 lumens/watt, CRI>70, PF > 0.95, CCT=5700±300, IP66,impact resistance IK 07, inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 10KV including suitable fixing arrangement with 40mm dia existing braket and connection suitable for 40mm dia braket with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmm x 3 core from light fitting to pole box complete all as specified and directed. |
| 20 | Supply and fixing in repair LED street light of capacity 90 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded toughned glass including electronic driver should have luminaire efficacy ≥140 lumens/watt, CRI>70, PF > 0.95, CCT=5700±300, IP66,impact resistance IK 07, inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 10KV including suitable fixing arrangement with 40mm dia existing braket and connection suitable for 40mm dia braket with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmm x 3 core from light fitting to pole box complete all as specified and directed. |
| 21 | Supply and fixing in repair LED street light of capacity 70 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded toughned glass including electronic driver should have luminaire efficacy ≥140 lumens/watt, CRI>70, PF > 0.95, CCT=5700±300, IP66,impact resistance IK 07, inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 10KV including suitable fixing arrangement with 40mm dia existing braket and connection suitable for 40mm dia braket with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmm x 3 core from light fitting to pole box complete all as specified and directed. |
| 22 | Supply and fix in repair LED Garden spike light 12 W , with dust jet water protection including taking down old u/s and making necessery connections complete all as specified and directed. |
| 23 | Supply and fixing repair LED light water proof light having IP-68 under water Led light 10 watt compatible for fountains white/warm white colour including taking down old u/s and making necessary connections complete all as specified and directed. |
| 24 | Supply and fixing in repair LED warm white bollard light 9W LED bollard with opal acrylic diffuser having arrangements for replacing the LED bulbs and IP66 protection suitable for dia upto 60mm complete all as specified and directed. |
| 25 | Supply and fixing in repair warm white LED 20 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed. |
| 26 | Supply and fixing in repair warm white LED 40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed. |
| 27 | Supply only LED flood light warm white/ cool day/ green colour 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. |
| 28 | Supply only LED flood light warm white/ cool day/ green colour 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. |
| 29 | Supply only LED flood light warm white/ cool day/ green colour 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. Please Enable Macros to View BoQ information |
| 30 | Supply only LED flood light warm white/ cool day/ green colour 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed. Please Enable Macros to View BoQ information |