Tender For Special Repairs To Roofs And Other Connected Works In Bldg No. T-1, T-2, T-3 Of 4/8 Gr Under Age B/R (Meg) Of Ge (North) Bangalore
Tender Value
45.50 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
17 days left
EMD
91000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Roofs And Other Connected Works In Bldg No. T-1, T-2, T-3 Of 4/8 Gr Under Age B/R (Meg) Of Ge (North) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each etc complete all as specified and as directed |
| 3 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4.0 Sqm each etc complete all as specified and as directed |
| 4 | M&L for 75 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade \\"A\\" complete all as specified and directed. |
| 5 | M&L Pre-cast Cement concrete Type 1:3:6 using (20 mm graded stone aggregates) with solid blocks, exc 10 cm in width and setting in CM 1:6 incl demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed. |
| 6 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed |
| 7 | M&L for rendering 10 mm thick in CM (1:6) on other than fair faces of brick work or concrete/stone masonry surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed |
| 8 | M&L for rendering 10 mm thick in CM (1:6) first layer and rendering 5 mm thick second layer in CM(1:4) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction finished even and smooth without using extra cement etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 9 | M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 10 | Supply only water proofing compound (Liquid) complete all as specified and as directed. |
| 11 | M & L for vitrified ceramic tiles dark shade double charged 10 mm thick (square / rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 12 | All as per item No 11 above but as in skirting /dado incl chemical adhesive glue 10 mm thick in CM 1:3 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 13 | S&F 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 14 | S&F Steel window Box type double side shutters (Windows side hung type, Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm, windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh be incl. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose .(Note : All Windows/Vent design as per CECZ TD drg No 539) |
| 15 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 16 | S&F 35mm thick flush shutter solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 17 | S & F 35 mm Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed |
| 18 | S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed |
| 19 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 20 | S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed |
| 21 | S&F 150 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed |
| 22 | M&L for 1mm thick wall care putty on wall including preparation of surface with sand paper etc to obtain smooth surface etc complete all as specified and as directed |
| 23 | M&L for Preparing new plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of alkali resistance primer complete all as specified and as directed |
| 24 | M&L preparing newely plastered surface of wall and applying one coat of cement base paint over a coat of alkali resistance primer etc complete all as specified and as directed |
| 25 | M&L preparing old plastered surface of wall and applying one coat of cement base paint complete all as specified and as directed |
| 26 | M&L for Preparation of old and new wooden surfaces of any description, over 10 cm in width or girth, and applying one coats of synthetic enamel paint etc complete all as specified and as directed |
| 27 | M&L for Preparation of old or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint etc complete all as specified and as directed |
| 28 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws etc incl dismantling of asbestos cement roofing etc complete all as specified and as directed |
| 29 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in ridges / valley to wall, fixed with self tapping screws incl dismantling of Ridges etc complete all as specified and as directed |
| 30 | Dismantling of timber scantlings unframed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section description complete all as specified and directed. |
| 31 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality-A etc complete all as specified and as directed |
| 32 | Dismantling of wall and ceiling boards any thickness of any description including cover fillets complete all as specified and directed. |
| 33 | S&F in position suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 3mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips, complete all as specified and directed. |
| 34 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets, light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories concealed on walls/ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.One light / fan/ Exhaust Fan point controlled by one switch |
| 36 | All as per item No. 35 above but forOne 3 pin socket out let 5 Amps on independent board |
| 37 | All as per item No. 35 above but forOne 3 pin socket out let 5 A on same board |
| 38 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories concealed on walls/ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 & 3 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in point wiring. |
| 39 | S&F of LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. |
| 40 | S&F of switch piano flush type single pole one way 5 Amps |
| 41 | S&F of stepped type electronic fan regulator flush switch type all as specified and as directed |
| 42 | S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed |
| 43 | S&F of switch socket combination 2 in 1, 3 pin 6 and 16 Amps flush type universal all as specified and as directed |
| 44 | S&F in replacement of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 45 | S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 46 | S&F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 47 | S&F of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 48 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed and taking out old unsv items. |
| 49 | Supply and fixing in replacement 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fitting. |
| 50 | S&F in replacement GI Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed. |
| 51 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of PVC conduit concealed type all as specified and as directed |
| 52 | S&F in replacement of MCB TPN 415 volts 10 KA 'C' 63 Amps complete all as specified and as directed |
| 53 | M & L excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 54 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 55 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 56 | M & L for sand cushioning with a layer of M sand 23 cm thick under and above the cable complete all as specified and as directed |
| 57 | S&L sub class 'B' burnt bricks for cable protection complete as specified as directed |
| 58 | S&L cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking out the existing unserviceable cable for following size 3.5 C x 16 Sqmm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender