Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56200659

Tender For Repair/Maint Of Summer Appliances, Water Heater And Connected Works At Misa C Under Ge (S) Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
24 Lakhs
Estimated cost
Bid Submission
11 Jul 2026
5 days left
EMD
48000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Summer Appliances, Water Heater And Connected Works At Misa C Under Ge (S) Tezpur

BOQ

Name of Work:- REPAIR/MAINT OF SUMMER APPLIANCES, WATER HEATER AND CONNECTED WORKS AT MISA C UNDER GE (S) TEZPUR
Sl. No. Item Description
1S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) suitable for existing geysers 25 litrs capacity etc complete all as specified and as directed
2S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed
3S&F in replacement of thermostat suitable for water heater of any size/type complete all as specified and as directed
4S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade, complete all as specified and as directed
5S&F in replacement of plug top 3 pin 16 amps ISI marked, complete all as specified and as directed
6S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series complete all as specified and as directed
7M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
8S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as specified and as directedNote: Rate of Refrigrant R-134a shall be included in quoated rate.
9S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
10S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.
11S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
12S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler complete all as specified and as directed
13S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity complete all as specified and as directed
14S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC complete all as specified and as directed
15S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
16Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
17M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as specified and as directedNote: Rate of Refrigrant R-134a shall be included in quoated rate.
18S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
19S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
20S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
21S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
22S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
23S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed..
24S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed.
25S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
26S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC complete all as specified and as directed
27S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC complete all as specified and as directed
28S&F in replacement of insulation cover of size 5/8\\" for insulating copper tube of split type AC complete all as specified and as directed
29S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC complete all as specified and as directed
30S&F in replacement PVC insulated & PVC Sheathed three core cable of size 4.0 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI complete all as specified and as directed.
31M&L for leak testing with nitrogen dioxide and refilling with refrigerant as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as specified and as directed.
32M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as specified and as directed.
33S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
34S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
35S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type complete all as specified and as directed
36S&F in replacemet of water purifier stainer for pre filter of single candle complete all as specified and as directed.
37S&F in replacemet of water purifier candle filter for existing RO filters complete all as specified and as directed.
38M&L for servicing refrigerator/depp freezer of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete all as specified and as directed.
39M&L for servicing of water purifier refrigerator/depp freezer of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete all as specified and as directed.
40M&L for servicing water cooler of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling to entire satisfaction of Engr-in-Charge.
41M&L for servicing air conditioner of any capacity and any tupe (window and split) after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge.
42S&F in replacement of control circuit (PCB) with remote device for ourdoor/indoor unit suitable for 1.5/2.0 Ton Split type AC inverter type of existing make and model complete all as specified and directed.
43Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing, replacement of condenser etc and re-assembling the same including necessary transportation etc complete including taking down complete all as specified and directed.
44NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56200659
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24 Lakhs
LAST DATE 11-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Summer Appliances, Water Heater And Connected Works At Misa C Under Ge (S) Tezpur
Basic Detail
Tender No 9131
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 27 Jun 2026
Submission Date 11 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 24 Lakhs
Tender Fee 500
EMD 48000
Exemption Available
Document List
Addldocus.pdf
BOQ_867985.xls
f86a7955-dbf1-46ba-a6a9-c76ce6a945ac.html
Tenderdocus.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

Addldocus.pdf

xls

BOQ_867985.xls

html

f86a7955-dbf1-46ba-a6a9-c76ce6a945ac.html

pdf

Tenderdocus.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders