Tender For Repair To Point Wiring, Sub Main Wiring, Switches, Sockets, Dbs, Mcbs, Mccbs And Allied Works At Domestic Area Of Afs Kumbhirgram.
Tender Value
9.50 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
5 days left
EMD
19000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Point Wiring, Sub Main Wiring, Switches, Sockets, Dbs, Mcbs, Mccbs And Allied Works At Domestic Area Of Afs Kumbhirgram.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed |
| 2 | Material and labour for concealed point wiring for one light/ Fan point controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including 20 mm dia (medium grade) non metallic PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes(concealed type) with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc or metal flush boxes suitable for mounting modular switches, sockets etc, including testing on completion, including cutting chases for concealed conduit , making good the disturbed surfaces using cement mortar 1:3 complete all as specified and directed. |
| 3 | All as per item No 2 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. |
| 4 | All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
| 5 | All as per Item No 2 here-in before but for one three pin switch socket outlet, 5 Amp on independent board complete all as specified and directed. |
| 6 | All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed. |
| 7 | Material and labour for point wiring (surface type) for one light/ Fan point controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including PVC rectangular switch board with plastic laminated sheet cover for mounting switches, sockets, fan regulators etc or modular plastic surface boxes suitable for mounting modular switches, sockets etc including testing on completion complete all as specified and directed. |
| 8 | All as per item No 7 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. |
| 9 | All as per item No 7 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
| 10 | All as per Item No 7 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 11 | All as per item No 7 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed |
| 12 | All as per item No 7 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 4.0 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed |
| 13 | cutting chases for concealed conduit wiring, making good to the disturbed surfaces, facing and pointing in cement mortar 1:3 in brick walls, cutting not exc 10 cm girth, complete all as specified and directed |
| 14 | M&L for sub main wiring with 2 run of single core 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 25 mm alongwith accessories on roof/walls/ ceiling etc including one run of 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 4.0 Sqmm single core cable, one run of 4.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length |
| 15 | M&L for sub main wiring with 2 run of single core 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 32 mm alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length |
| 16 | Supply and fix in repair PVC casing and caping of size 32 x12 mm complete all as specified and directed. |
| 17 | Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed |
| 18 | Supply and fix socket outlet 5 pin, 6 Amps complete all as specified and directed |
| 19 | Supply and fix bell push, flush type, 6 Amps, complete all as specified and directed |
| 20 | Supply and fix call Bell AC 230 Volts, single pole, complete all as specified and directed |
| 21 | Supply and fix Switch Socket combination 2 in 1, 6A flush type 5 pin, 230 volts complete all as specified and directed |
| 22 | Supply and fix Switch socket combination 2 in 1,3 pin, 6 amps and 16 amps flush type universal shuttered, complete all as specified and directed |
| 23 | Supply and fix Ceiling rose, 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed |
| 24 | Supply and fix lamp holder PVC / Polycarbonate type with back plate suitable for batten fittings (ISI Marked) complete all as specified and directed |
| 25 | Supply and fix Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps (ISI Marked), complete all as specified and directed |
| 26 | Supply and fix modular switch 1 way 6 Amps 1 Module complete all as specified and directed |
| 27 | Supply and fix modular switch 1 way 16 Amps 1 Module complete all as specified and directed |
| 28 | Supply and fix modular bell push 6 Amps 1 Module complete all as specified and directed. |
| 29 | Supply & fix modular socket 2 in 1,5 pin 6 Amps, 2 modules complete all as specified and directed |
| 30 | Supply & fix modular socket 2 in 1,3 pin 16 Amps, 2 modules complete all as specified and directed |
| 31 | Supply and fix Modular Fan regulator,100 watts 2 modules complete all as specified and directed |
| 32 | Supply and fix white modular cover plate with frame 1 Module complete all as specified and directed. |
| 33 | Supply and fix white modular cover plate with frame 2 Module complete all as specified and directed. |
| 34 | Supply and fix white modular cover plate with frame 3 Module complete all as specified and directed |
| 35 | Supply and fix white modular cover plate with frame 4 Module complete all as specified and directed |
| 36 | Supply and fix white modular cover plate with frame 6 Module complete all as specified and directed. |
| 37 | Supply and fix white modular cover plate with frame 8 Module complete all as specified and directed. |
| 38 | Supply and fix sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
| 39 | Supply and fix sheet metal enclosure MCB DB 6 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
| 40 | Supply and fix sheet metal enclosure MCB DB 8 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
| 41 | Supply and fix sheet metal enclosure MCB DB 12 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
| 42 | S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed |
| 43 | S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 32-40 Amps, \\"C\\" series,10 KA breaking capacity, complete all as specified and directed |
| 44 | Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB obtained from unserviceable DBs shall be reused) complete all as specified and directed |
| 45 | Supply and fix in repair LED tube light fittings 1 x 09/10 Watt two feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 46 | Supply and fix in repair LED tube light fittings 1 x 18/20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 47 | Supply and fix in repair wall mounted bulk head LED light fitting 10 W, made up of poly carbonate housing with diffuser & intigrated electronic driver and necessary electric connection complet all as per specified and directed. |
| 48 | Supply and fix in repair indoor commercial LED Luminaires Plano 2ftX2ft 36 watt ultra modern recess mounting luminaire with high performance LEDs suitable for mounting with grid ceiling and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. |
| 49 | Supply and fix in repair of LED lamp with in built driver with metal heat sink double sided connection of capacity 1x 18 watts all as specified and directed. |
| 50 | Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 4 mm dia galvanised iron as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 51 | Supply and fixing in repair switch socket combination 5 Pin 6 Amp with PVC Box complete all as specified and directed. |
| 52 | Supply and fixing in repair switch socket combination 3 Pin 16 Amp with PVC Box complete all as specified and directed. |
| 53 | Supply and fix in repair Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps (ISI Marked) complete all as specified and directed. |
| 54 | Supply and fixing in repair of Modular Fan regulator,120 watts 2 modules complete all as specified and directed. |
| 55 | Supply and fix in repair Switch piano flush button single pole, one way 5 Amp,complete all as specified and directed. |
| 56 | Supply and fix in repair modular switch 1 way 6 A, 1 Module complete all as specified and directed |
| 57 | Supply and fix in repair bell push, flush type, 5 Amps, complete all as specified and directed |
| 58 | Supply and fix in repair call bell AC 230 Volts, single pole,complete all as specified and directed. |
| 59 | Supply and fixing in repair sheet metal encloser with socket plug top and MCB single pole 20 Amp, 240 V complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender