Project Description

Tender for Repair/Replacement Of External Electric Supply Distribution Network With Other Connected Items At Malad, Marve & Kandivali Under Ge (N) Santacruz, Mumbai

BOQ

Name of Work:- REPAIR/REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY DISTRIBUTION NETWORK WITH OTHER CONNECTED ITEMS AT MALAD, MARVE & KANDIVALI UNDER GE (N) SANTACRUZ, MUMBAI
Sl. No. Item Description
1Supply, install, testing & commissioning pedestal cubical type double door LT bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick CRCA sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all Aluminium bus bar strips (50mm x 10mm x 04 Nos) & GI strip for Earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel including dismantling of old Bus bar panel all as specified and directed by Engr-in Charge.Notes:-(a) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set(b) MCCB 4 pole , Ics=100%Icu- 25 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.(c) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio.-01 No Make- IMP/Automatic Electrical(AE)/ L&T / Havells/ MECO(d) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos(e) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job(f) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.Make of MCCB & MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
2Supply & Fixing MCCB 4 pole 36 KA 400 Amp with Adjustable thermal & adjustable magnetic setting, including taking down old unserviceable MCCB, all as specified and directed by Engr-in-Charge. Make:- Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
3Supply & Fixing MCCB 4 pole 36 KA 160 Amp with Adjustable thermal & adjustable magnetic setting, including taking down old unserviceable MCCB, all as specified and directed by Engr-in-Charge. Make:-Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
4Supply & Fixing MCCB 4 pole 16 KA 100 Amp with Adjustable thermal & adjustable magnetic setting, including Taking down old unserviceable MCCB, all as specified and directed by Engr-in-Charge. Make:-Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
5Supply & Fixing MCCB 4 pole 36 KA 250 Amp with Adjustable thermal & adjustable magnetic setting, including Taking down old unserviceable MCCB all as specified and directed by Engr-in-Charge Make:-Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
6Supplying, laying,connecting, testing & commissioning LT UG PVC insulated, heavy duty, 1100 V grade electric cable with aluminium conductor of size 16 Sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:-Note : Earthwork excavation, DWC/GI pipe for cable protection shall be measured and paid separately in their respective itemsMake: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI)
7-do- same as Item no. 6 above but of size 25 Sqmm 4 Core
8-do- same as Item no. 6 above but of size 35 Sqmm 3.5 Core
9-do- same as Item no. 6 above but of size 50 Sqmm 3.5 Core
10-do- same as Item no. 6 above but of size 70 Sqmm 3.5 Core
11-do- same as Item no. 6 above but of size 95 Sqmm 3.5 Core
12Supply and lay double wall corrugated (DWC) HDPE pipe 63mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-ChargeMake : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral
13Material and labour for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation, laying pipes etc or for shaft, walls, manholes, pier holes etc not exceeding 10 sqm on plan and not exceed 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge
14Returning, filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed by the Engineer-in-Charge
15Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
16Material & Labour for finding cable fault with electronic fault detector in LT UG cable of any size raging from 25 to 400 Sqmm 3.5 core, complete including necessary earthwork all as specified and directed by Engineer-in-charge.
17Material and labour for earthing complete with Galvanised steel earth plate electrode 60cm X 60cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with GI earth wire 32 x 6mm GI earth strip, 7.5m long from earth point to test point and other end connected to control board / panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt not less than 50Kg, in each earthing packed up to maximum 30 cm on both side of plate and GI strip protected by 40mm bore light grade galvanized iron pipe complete all as shown in electrical plate No. 3 of MES schedule Part I, 2009 with PCC 1:3:6, type C1 in chamber wall with CI cover and frame, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh and engraving of earth marking on nearby structure/ building with cement mortar 1:4 plate of size 200mm x 150mm x 15mm thick including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.Note :- (i) Contractor should submit test report of earthing after installation to Engineer -in-Charge (ii) All joints shall be made with welding to get proper conductivity
18Material & Labour for cutting the existing bitumen road/hard standing to size not exceeding 45 cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surfaces as per existing road/ hard standing including refilling the excavated material, compacting, aggregate/ Road ready mix following the stone/sand on top complete all as specified and directed by engr-in-charge.
19Supply & Fixing MCCB 4 pole 16 KA 63 Amp with Adjustable thermal & adjustable magnetic setting, taking down old unserviceable MCCB, all as specified and directed by Engr-in-Charge. Make- Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
20Material and labour for straight Through Heat shrinkable type Cable Joint Kit including Jointing Materials for making Joints of LT UG Electric Cable 1100 Volt Grade Heavy Duty with XLPE insulated Aluminium Stranded Conductor of size 25 to 50 Sqmm x 3½ Core and Testing complete all as specified and as directed. Make: Densons/ M Seal/ Raychem/ Siemens / Birla 3M/ Mahindra & Mahindra
21All as per item No 20 described here-in-before but of size 70 Sqmm to 120 Sqmm x 3½ Core and Testing complete all as specified and as directed.
22All as per item No 20 described here-in-before but of size 240 Sqmm to 300 Sqmm x 3½ Core and Testing complete all as specified and as directed.
23Supply and fix , Low voltage Standard duty Power capacitor of 25 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make-Schneider, L&T, Siemens
24Supply and fix , Low voltage Standard duty Power capacitor of 10 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens
25Supply and fix , Low voltage Standard duty Power capacitor of 5 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make-Schneider, L&T, Siemens
26Supply and fix , Low voltage Standard duty Power capacitor of 7.5 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make-Schneider, L&T, Siemens
27Supply and fix , Low voltage Standard duty Power capacitor of 3 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make-Schneider, L&T, Siemens
28Supply and fix , Low voltage Standard duty Power capacitor of 2 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make-Schneider, L&T, Siemens
29Decarbonising of LT Panel board / Feeder pillar boxes by CTC (Carbon Tetra Chloride). Removing the carbon deposited inside the panel. Cleaning the panel with cotton waste . Applying one coat of becktol red solution , Checking the faults inside the panel board, Charging the LT Panel post completion of decarbonisation . Note : a) Proper shut down shall be taken prior the commencement of work . b) Contractor shall provide CTC , Cotton waste and Dr Bectol solution for performing the decarbonisation. c) Fabrication of LT Panels for broken hinges shall be rectified and paid seperately under relevant item. d) Painting the LT Panel with synthetic enamel paint ( 2 coats) over one coat of red oxide ( 1 coat)
30Material & Labour for cleaning of E/M installations / campus by deploying labour in each installation, surface dressing, cutting/ dressing of natural grass from ground to remove small unequalities n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ), cleaning of drains & carrying away the rubbish to a distance of n.exc 50 mtr away complete, the area of installation up to 700sqm complete all as specified and directed.
31Supply and fix in replacement of multifunctional meter in existing panel/ feeder 3 phase 4 wire CT operated with necessary CT copper wournt out of rating 300/5 Amps for 3 phase, 15 VA, Class-I accuracy suitable for recording KWH, KVA, KW, KVAh, PF etc, flush mounted 96x96mm, input voltage measurement range 50-520 VAC, including necessary wiring for connections all as specified and as directed by Engineer-in-Charge. Make: L&T Cat No. WL4405110000 or equivalent of C&S/ABB as approved by GE
32Supply & fix digital ammeter 0-400 Amps,3 phase,with selector switch for existing panel complete all as specified and directed.Make:MP/Automatic Electrical(AE)/ L&T / Havells/ MECO
33Supply & fix digital volt meter 0-500 Volts, 3 phase with selector switch of 10 Amp for existing panel complete all as specified and directed.Make: MP/Automatic Electrical(AE)/ L&T / Havells/ MECO
34Refixing / relaying of existing disturbed / uprooted existing LT electric cable of size upto 300 Sqmm to the existing places like uprooted from ground or out with the steel saddles from ground level to four storey bldg distribution box,etc complete with using electric drill machine, nut & bolt and proper grouted including excavation, return and filling, removing and DWC pipe/ Cable covers as required all as specified and as directed.
35Material and labour for welding broken doors of LT Panels (front and rear door) including replacing the required new hinges, nuts and bolts, locking arrangement and refixing the covers without disturbing the existing electric system complete all as specified and directed by Engr-in-charge.
36Supply and fix , Current Transformer resin of ratio 400/5A with frequency 50Hz, class 1.0 voltage ranging upto 660 Volts, having long life expectancy, shock hazard, including taking down old unserviceable Current Transformer all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens, AE
37Trimming of trees of any height or any size inside Pump house/ Power house/around Street light with the help of crane/ skilled wood cutter complete with removing all cutted trees outside the MD land,complete all as specified and directed by Engr-in-charge.
38Material & Labour for feeder pillar box outdoor type double door, vermin and weather proof of suitable size with minimum depth 0.5 meter made out of 3 mm thick on Outer Cover & 2mm thick on Inner Cover CRCA sheet including canopy type roof 15 cm extended in all side and two part hinged door in front sides with locking arrangement and gasket arrangement with one Nos pad lock and three Nos keys and back side fixed with nuts & guskets, including provision of one set of bus bar (4 Nos. aluminum strip of size 40mmx10mm ) & GI strip of suitable size for earth as outgoing fixed on porcelain insulator and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom or upper part as mentioned below, complete electrically inter connected with Aluminium strips of suitablesize for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel including two coat of powder coated paint and consisting of the following accessories including dismantling of old panel all as directedNote:- (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge(b) The cost of dismantling of old panel/F/piller Box is deem to be included above.(c) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set(d) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio.-01 No Make- IMP/Automatic Electrical(AE)/ L&T / Havells/ MECO(e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos(f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job
39Incoming :-(a) MCCB 4 pole ,Ics=100%Icu- 36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.Outgoing :-(b) MCCB 4 pole , Ics=100%Icu- 25 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos.(c) MCCB 4 pole , Ics=100%Icu- 16 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos.(d) Automatic Astro time Switch panel mounted flush to panel door,230V AC with one selector switch for auto/manual selection Make:- L&T Part No AUSTS02ASTOO/Legrand/Schnider-01 Nos.(e) Power contactor 3 pole AC,with 230V coil,70amps rating with suitable size MCB for control, Make: L&T Type MNX70, Cat No CS97076/Schenider Electric/BCH-01 Nos.(f) Necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.Make of MCCB & MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
40Material & Labour for feeder piller box outdoor type double door, vermin and weather proof of suitable size with minimum depth 0.5 meter made out of 3 mm thick on Outer Cover & 2mm thick on Inner Cover CRCA sheet including canopy type roof 15 cm extended in all side and two part hinged door in front sides with locking arrangement and gasket arrangement with one Nos pad lock and three Nos keys and back side fixed with nuts & guskets, including provision of one set of bus bar (4 Nos. aluminum strip of size 40mmx10mm ) & GI strip of suitable size for earth as outgoing fixed on porcelain insulator and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom or upper part as mentioned below, complete electrically inter connected with Aluminium strips of suitablesize for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel including two coat of powder coated paint and consisting of the following accessories including dismantling of old panel all as directedNote:- (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge(b) The cost of dismantling of old panel/F/piller Box is deem to be included above.(c) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set(d) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio.-01 No Make- IMP/Automatic Electrical(AE)/ L&T / Havells/ MECO(e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos(f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job
41Incoming :-(a) MCCB 4 pole ,Ics=100%Icu- 36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.Outgoing :-(b) MCCB 4 pole , Ics=100%Icu- 25 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.(c) MCCB 4 pole , Ics=100%Icu- 16 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.(d) Automatic Astro time Switch panel mounted flush to panel door,230V AC with one selector switch for auto/manual selection Make:- L&T Part No AUSTS02ASTOO/Legrand/Schnider-01 Nos.(e) Power contactor 3 pole AC,with 230V coil,70amps rating with suitable size MCB for control, Make: L&T Type MNX70, Cat No CS97076/Schenider Electric/BCH-01 Nos.Make of MCCB & MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
42Material & Labour for feeder piller box outdoor type double door, vermin and weather proof of suitable size with minimum depth 0.5 meter made out of 3 mm thick on Outer Cover & 2mm thick on Inner Cover CRCA sheet including canopy type roof 15 cm extended in all side and two part hinged door in front sides with locking arrangement and gasket arrangement with one Nos pad lock and three Nos keys and back side fixed with nuts & guskets, including provision of one set of bus bar (4 Nos. aluminum strip of size 40mmx10mm ) & GI strip of suitable size for earth as outgoing fixed on porcelain insulator and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom or upper part as mentioned below, complete electrically inter connected with Aluminium strips of suitablesize for all incoming and outgoing MCCBs and accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers, Danger notice board with scull suitable for 415 volts or required size to be fixed on Pannel including two coat of powder coated paint and consisting of the following accessories including dismantling of old panel all as directedNote:- (a) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-Charge(b) The cost of dismantling of old panel/F/piller Box is deem to be included above.(c) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set(d) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable CT of appropriate ratio.-01 No Make- IMP/Automatic Electrical(AE)/ L&T / Havells/ MECO(e) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos(f) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job
43Incoming :-(a) MCCB 4 pole ,Ics=100%Icu- 36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.Outgoing :-(b) MCCB 4 pole , Ics=100%Icu- 16 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -04 Nos.(c) Automatic Astro time Switch panel mounted flush to panel door,230V AC with one selector switch for auto/manual selection Make:- L&T Part No AUSTS02ASTOO/Legrand/Schnider-01 Nos.(d) Power contactor 3 pole AC,with 230V coil,70amps rating with suitable size MCB for control, Make: L&T Type MNX70, Cat No CS97076/Schenider Electric/BCH-01 Nos.
44Material & Labour for feeder piller box outdoor type double door, vermin and weather proof of suitable size with minimum depth 0.5 meter made out of 3 mm thick on Outer Cover & 2 mm thick on Inner Cover CRCA sheet including canopy type roof 15 cm extended in all side and two part hinged door in front sides with locking arrangement and gasket arrangement with one Nos pad lock and three Nos keys and back side fixed with nuts & guskets, including provision of one set of bus bar (4 Nos. aluminum strip of size 40mmx10mm ) & GI strip of suitable size for Earth as outgoing fixed on porcelain insulator and provision of cable gland for cable entry including two coat of powder coated paint complete and installation on PCC foundation all as directed including provision of following parameters:-Incoming :-(a) Material & Labour fo one numbers of incoming MCCB's 160 Amp rating, 36KA bracking capacity with extended terminals, suitable size aluminium connection busbers covered with PVC sleeves out going sides of MCCB's inside the feeder piller box, all as directed as per site requirement.Outgoing :-(b) MCCB 4 pole , Ics=100%Icu- 25 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.(c) Aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for Phases and neutral - 01 set(d) Panel shall be Manufactured from CPRI approved manufacturer and Drawing for Feeder pillar box shall be first approval by Engr-in-ChargeMake of MCCB & MCB: Larsen &Toubro/ ABB/ Siemens/ Schneider/ Havells/ Legrand/ Indo ASIAN/ C & S Electric/ Bhartia Cuttler Hammer (BCH)/Benlo
45Supply and fix Current Transformer resin of ratio 800/5A with frequency 50Hz, class 1.0 voltage ranging upto 660 Volts, having long life expectancy, shock hazard, including taking down old unserviceable Current Transformer all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens, AE
46Supply and fix , Current Transformer resin of ratio 200/250/5A with frequency 50Hz, class 1.0 voltage ranging upto 660 Volts, having long life expectancy, shock hazard, including taking down old unserviceable Current Transformer all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens, AE
47Note: Deduct Credit for demolished / dismantled material of Rs. (-) 67,325.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56200631
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 18-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of External Electric Supply Distribution Network With Other Connected Items At Malad, Marve & Kandivali Under Ge (N) Santacruz, Mumbai
Basic Detail
Tender No 8317/E8
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 27 Jun 2026
Submission Date 18 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
959d4265-bddb-4ce2-93e1-2f8c7355ae49.html
BOQ_867869.xls
GENPAGES8317.pdf
PS8317.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

959d4265-bddb-4ce2-93e1-2f8c7355ae49.html

xls

BOQ_867869.xls

pdf

GENPAGES8317.pdf

pdf

PS8317.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders