Tender For Repair To Internal Electrification In Otm Accn Including Submain And Distribution At Af Stn Chandigarh Under Ge (Af) Chandigarh.
Tender Value
20 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Internal Electrification In Otm Accn Including Submain And Distribution At Af Stn Chandigarh Under Ge (Af) Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for point wiring with single core multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn through in and including non metalic rigid PVC conduit of size19 mm dia or higher size , medium grade with all standard fittings on existing sunken terminal boxes with new 3 mm thick PVC laminated sheet for mounting piano type switch/sockets etc and incl 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLS colour code cable 1100 volts grade for earth continuity including taking down copper/aluminium point wiring (light, fan, socket or power) complete, including conduits/casing caping etc and making good disturbed surface of walls, floors, etc for the following complete all as specified and directed:- |
| 2 | One light point controlled by one switch/ fan point controlled by one switch . |
| 3 | One three pin 6 amp socket outlet multipurpose on independent board. |
| 4 | One three pin 6 Amp switch socket outlet on the same board with other switches. |
| 5 | All as per item No 1.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete.Note for item No. 1.01 to 1.03 & 2.00 : Sunken terminal boxes if required shall be measured and paid separately under respective item. |
| 6 | M&L for point wiring with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn through in and including PVC casing & caping of suitable size with all standard fittings on existing sunken terminal boxes with new 3 mm thick PVC laminated sheet for mounting piano type switch/sockets etc and incl 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLS colour code cable 1100 volts grade for earth continuity including taking down copper/aluminium point wiring (light, fan, socket or power) complete, including conduits/casing caping etc and making good disturbed surface of walls, floors, etc for the following complete all as specified and directed:- |
| 7 | One light point controlled by one switch/ fan point controlled by one switch . |
| 8 | One three pin 6 amp socket outlet multipurpose on independent board. |
| 9 | One three pin 6 Amp switch socket outlet on the same board with other switches. |
| 10 | All as per item No 3.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete.Note for item No 3.01 to 3.04 & 4.00: Sunken terminal boxes if required shall be measured and paid separately under respective item. |
| 11 | M&L for point wiring using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete in existing concealed/surface conduit and sunken terminal boxes with new 3 mm thick PVC laminated sheet for mounting of piano type switches, sockets, fan regulators etc with screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly including taking down copper/aluminium point wiring (light, fan, socket or power) complete from exiting concealed/surface conduits/casing caping etc and making good disturbed surface of walls, floors, etc for the following complete all as specified and directed:- |
| 12 | One light point controlled by one switch/ fan point controlled by one switch . |
| 13 | One three pin 6 amp socket outlet multipurpose on independent board. |
| 14 | One three pin 6 Amp switch socket outlet on the same board with other switches. |
| 15 | All as per item No 5.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete.Note for item No 5.01 to 5.04 & 6.00: Sunken terminal boxes if required shall be measured and paid separately under respective item. |
| 16 | S&F in replacement of switch piano type, flush type, single pole, one way, 6 Amps complete all as specified and directed. |
| 17 | S&F in replacement of socket outlet flush type 2/ 3 pins, 6 Amps multipurpose complete all as specified and directed. |
| 18 | S&F in replacement of switch piano type, flush type, single pole, one way, 16 Amps complete all as specified and directed. |
| 19 | S&F in replacement of socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts complete all as specified and directed. |
| 20 | S&F in replacement ceiling fan regulators, step type, electronic for 1200/ 1400mm sweep complete all as specified and directed. |
| 21 | M&L for submain wiring complete with two runs of 4.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductor shall be considered as one unit length. |
| 22 | M&L for submain wiring complete with two runs of 6.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 6.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length. |
| 23 | M&L for submain wiring complete with four runs of 10.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 10.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Four runs of 10.0 sqmm multi-stranded cable and one run of 10.0sqmm cable as earth continuity conductor shall be considered as one unit length. |
| 24 | S&F in replacement sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc complete with & including SP MCB 6-32 Amps, 240 volts 10 KA all as directed . |
| 25 | S&F in replacement MCB SP 240 volts 6 to 32 Amps 'B' curve type all as specified and directed. |
| 26 | S&F in replacement MCB SP 240 volts 63 Amps 'C' curve type all as specified and directed. |
| 27 | S&F in replacement SPN RCBO 240 volts 40 Amps 100mA complete all as specified and directed. |
| 28 | S&F in replacement MCB SPN 240 volts 32 to 40 Amps ‘B’ curve complete all as specified and directed. |
| 29 | S&F in replacement MCB FP 415 volts 40 to 63 Amps ‘B’ curve complete all as specified and directed. |
| 30 | S&F in replacement of MCCB TP 63 to 100 Amps, 415 volts AC, 25 KA complete all as specified and directed. |
| 31 | S&F in replacement of MCCB FP 63 to 100 Amps, 415 volts AC, 25 KA complete all as specified. |
| 32 | S&F in replacement of MCCB FP 125 Amps, 415 volts AC, 25 KA complete all as specified. |
| 33 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 12 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 34 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 35 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 4 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 36 | S&F in replacement LED lights fitting 4 feet long 1x 20 W, 220V, AC decorative box batten type with driver, holder etc including electrical connection with ceiling rose complete all as directed. |
| 37 | S&F in replacement LED lights fitting 2 feet long 1x 10 W, 220V, AC decorative box batten type with driver, holder etc including electrical connection with ceiling rose complete all as directed. |
| 38 | S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 39 | S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC surface mounting type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 40 | S&F in repairs LED luminaire 300mm x 300mm, 18 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 41 | S&F in repairs LED light fitting 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 42 | S&F in replacement LED street light fitting 45 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 43 | S&F in replacement LED street light fitting 60 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 44 | S&F in replacement LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 45 | S&F in replacement of LED flood light luminaries 150W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed. |
| 46 | S&F in replacement of LED flood light luminaries 200W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed. |
| 47 | S&F in repairs ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed. |
| 48 | S&F in replacement rigid non-metallic PVC conduit surface/concealed 25 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. incuding repairing the disturbed surface complete all as specified and directed. |
| 49 | S & F in replacement PVC insulated and sheathed twin core cable with aluminium conductor 10 sqmm size 1100 volts grade complete all as specified and directed. |
| 50 | Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed. |
| 51 | Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed. |
| 52 | Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core including taking up/ down existing cable complete all as specified and directed. |
| 53 | Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed. |
| 54 | Returning and filling in excavated soil in layer not exceeding 25cm thick in including spreading, levelling, watering and well ramming in soft/ loose soil complete all as specified and directed. |
| 55 | Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed. |
| 56 | M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid. |
| 57 | Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed. |
| 58 | S&F in replacement LED lamp 9 watt complete all as specified and directed. |
| 59 | S&F in replacement 18/ 20 watt LED tube rod 4’ long (as per existing) complete all as specified and directed. |
| 60 | S&F in replacement call bell AC 230 volts single pole complete all as specified and directed. |
| 61 | S&F in replacement slim design LED surface/ recessed mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 18 watt complete all as specified and directed. |
| 62 | S&F in replacement slim design LED surface/ recessed mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 15 watt complete all as specified and directed. |
| 63 | S&F in replacement slim design LED surface/ recessed mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 12 watt complete all as specified and directed. |
| 64 | S&F in replacement slim design LED recessed/surface mounted round/square polycarbonate housing down lighter with superior light output and integral driver of capacity 9 watt complete all as specified and directed. |
| 65 | M&L for replacement of LED light fitting 2 x 16/ 20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories duly prewired including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 66 | S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed. |
| 67 | S&F in replacement of LED driver suitable for 35/ 36 watt LED panel of size 600mm x 600mm fittings complete all as specified and directed. |
| 68 | S & F in replacement air freshner fan polycarbonate body 250 mm sweep single phase 230 volts with and including PVC shutters complete all as directed. |
| 69 | Supply and fixing in replacement PVC insulated single core FRLS stranded copper conductor 1100 volt grade cable of size 1.5 sqmm in existing surface/ concealed conduits complete all as specified and directed. |
| 70 | Supply and fixing in replacement PVC insulated single core FRLS stranded copper conductor 1100 volt grade cable of size 2.5 sqmm in existing surface/ concealed conduits complete all as specified and directed. |
| 71 | Supply and fixing in replacement PVC insulated single core FRLS stranded copper conductor 1100 volt grade cable of size 4.0 sqmm in existing surface/ concealed conduits complete all as specified and directed. |
| 72 | S&F in replacement surface mounting type plastic gang box suitable for mounting piano switch/sockets complete, made from high impact plastic with metal thread inserts complete all as directed for the following :- |
| 73 | For two/three ways |
| 74 | For four/six ways |
| 75 | S & F in replacement concealed type GI sheet metal boxes 18 gauge thickness box suitable for mounting piano switch/sockets complete with earthing terminal and good quality thread including making good the disturbed surfaces complete all as directed for the following :- |
| 76 | For two/three ways |
| 77 | For four/six ways |
| 78 | For eight ways |
| 79 | For twelve ways |
| 80 | M&L for replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead 4 mm dia GI wire by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge incl necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 15mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note :- Earth lead 4 mm dia GI wire and GI 15mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted. |
| 81 | Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysJul 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender