Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #56200596

Tender For Provn Of Toilet Block (02 X Bathrooms, 04 X Water Closet And 02 X Wash Basin For Troops At Hq 06 Sect Rr, Potha Under Age (I) Cif (R)

Issued by Statutory Bodies & Commissions/Committees · Rajouri, Jammu and Kashmir
Tender Value
9.67 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
6 days left
EMD
19340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Toilet Block (02 X Bathrooms, 04 X Water Closet And 02 X Wash Basin For Troops At Hq 06 Sect Rr, Potha Under Age (I) Cif (R)

BOQ

Name of Work:- PROVN OF TOILET BLOCK (02 X BATHROOMS, 04 X WATER CLOSET AND 02 X WASH BASIN FOR TROOPS AT HQ 06 SECT RR, POTHA UNDER AGE (I) CIF (R)
Sl. No. Item Description
1Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified.
2Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation and getting out in any type of soil complete, as directed & specified
3Providing cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate as in foundation, filling and mass concrete.
4Brick work with Sub Class ‘B’ burnt bricks (Old size bricks) straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6. completed, as directed & specified.
5M&L half brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
6Excavating over areas,n exc 1.5 m deep and getting out in soft/loose soil, complete all as specified.
7Returning, filling in any type of soil, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm.
8Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point completed as directed & specified.
9Reinforce cement concrete M-25 (20mm graded aggregates) design mix as in foundations, including rafts, footings, foundation, beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
10Reinforce cement concrete M-25 (20mm graded aggregates) design mix columns, pillars, piers,posts and struts complete all as specified and directed.
11Reinforce cement concrete M-25 (20mm graded aggregates) design mix as in beams, cantilevers,bressummers, lintels over 1.5m span all as specified and directed.
12Reinforce cement concrete M-25 (20mm graded aggregates) design mix as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed.
13Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter for rough flat finished surfaces of concrete,complete all as specified and directed.
14Formwork to sides of pillars,posts, struts, piers, columns and stanchions for rough flat finished surface of concrete, complete all as specified.
15Formwork to flat sides and soffits of or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, complete as per specified & directed.
16Formwork to soffits of suspended flat slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete as per specified
17Formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in wall, horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
18M&L for TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
19All as per srl item No. 18 above but 6 mm dia and over including 10mm dia in stirrups, spaces and binders etc all as specified.
20M&L for 10 mm thick on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified.
21M&L for 15 mm thick rendering on fair faces of brick/concrete or stone surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete with water proofing compound all as specified (WPC shall be measured separtely).
22Supply only integral water proofing compound all as specified
23Material and labour for 5 mm thick rendering in CM 1:3 on concrete ceiling surfaces including finishing even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
24M&L for preparation of new plastered surfaces on walls and applying three coats of white wash.complete all as specified and directed.
25M&L for preparation of new plastered surfaces on ceiling and applying three coats of white wash.complete all as specified and directed.
26Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat of chalk whitening primer complete all as specified and as directed by Engr-in-charge.
27M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified.
28M&L 75 mm thick cement concrete (1:4:8) type D2 as sub base to floor as specified.
29M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
30M&L for 10mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified.
31M&L for 10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified.
32M&L for Non-skid coloured ceramic tiles (square/rectangular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface,complete all as specified and directed.
33M&L for Glazed ceramic tiles in vertical surface 300 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface complete all as specified and directed.
34M & L for 75 mm thick cement concrete 1:3:6 type C 2 (40 mm graded aggregate ) as in plinth protection, finished even and smooth without using extra cement complete all as specified and directed
35M &L for forming 6/10mm thick expansion joint filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound complete all as specified and directed.
36S&F for mild steel ventilators (Box type) factory made with top hung shutters and bottom fixed type shutters incl pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded incl one shop coat of red oxide primer complete all as specified. Note : (i) The window shall be fabricated as per Drg CEUZ/TD/1269/2008 Sh 1/3 (ii) Glazing, wire gauge shall be measured and paid separately.
37Mild steel framed work such as grills, gratings,etc, with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bar ; barred iron doors, ladder ; framed balusters ; railing ; frame work for water tanks and similar work conforming to Fe-410,Gde-E-310, complete all as specified.
38Supply and fix 4mm thick sheet glass, frosted or grounded on one side with rubber beading around the glass, in squares n exc 0.50 sqm
39S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube and fixed in opening as per specification and drawing complete all as specified.
4030 mm thick, factory made solid panel PVC door shutter (style) consisting of frame made out of M.S tube for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rails and bottom rail on either side & as gap insert for top rail & bottom rail, Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, fixed in the frame at site as per specification and drawing complete all as specified and directed.
41Preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
42S&F aluminum handles cast type, anodised, 150 mm size complete all as specified .
43S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified .
44S&F stainless steel cold rolled butt hinges medium weight 100 mm long complete all as specified.
45M&L for 10 mm thick rendering in CM 1:3 on roof sufaces, finished even and smooth without using extra cement complete all as specified.Note :- Supply only water proofing compound shall be measured and paid seperately under the respective item.
46Material and labour for 3mm thick APP based polymeric membrane minimum weighing 3 kg/sqm non-woven polyester reinforcement polymeric water proofing membrane (wt not less than 150 gms/sqm) laid on primed surfaces by gas flame torch application and apply one coat of industrial bitumen 85/25 grade at the rate of 1.20 Kg/Sqm over APP Memberence complete all as specified and as directed by the Engineer-in-Charge.Note :- Water proofing treatment will be done by IWL or through a specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
47S&F for steel water tubing of nominal bore dia 15 mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified.
48S&F for steel water tubing of nominal bore dia 20 mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified.
49S&F for 20mm dia, Ball brass, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified .
50S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified .
51S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified .
52S&F for 1000 ltrs capacity rotational moulded polythylene water storage tank (Cylindrical vertical with closed top and triple layer with white colour) hoisted and fixed in position all as specified in SSR Part I.
53S&F in repair vitreous china wash down water closet pan (Orissa patern) of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed.
54S&F SS tubular towel rail, 20mm dia, D type, 60cm long between flanges , fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
55S&F for 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified. Make : CERA or equivalent
56Supply Only Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified.
57S & F Toilet paper holder with flat recessed type stailess steel complete all as specified and directed
58S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms)
59S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
60S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
61S&F for PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified.
62S&F for Angle valve, cast copper alloy fancy type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified.
63S&F, 15 mm dia bib tap fancy type chomium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified.
64S&F 15mm bore pillar tap cast copper alloy with capstan head chromium plated screwed down under high pressure with or without lettered hot or cold with long shank and fly nuts screwed for iron pipe.(Make Johnson /Cera or equivalent )
65S&F 32mm dia waste coupling of PTMT(half or full threaded) (Minimum weight 32mm ,45gms), completed all as specified.
66Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified.
67S&F SS grating 100mm dia fixed to floor trap in repair.
68S&F in repair PVC waste Pipe 32/40mm dia and fixed complete all as specified and directed
69Supply and fix in vitreous china wash hand basin white table top size 550x400mm excluding taps waste chain and plug and porcelain stopper but including brackets waste fitting brass chromium plated 32mm dia with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed etc complete all as specified and as directed by Engr-in-charge.
70S&F for PVC (SWR) floor trap with dia of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete PCC 1:2:4 type B-1 complete all as specified.
71S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
72S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls
73S&F 75 mm PVC (SWR) bends any radius
74S& F 110 mm bore PVC SWR bends and fixed with joint sealent etc complete all specified and as directed
75S&F stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 100mm bore of pipe complete all as specified and as directed.
76S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal
77S&F 75 mm PVC (SWR) junction double, (double T), equal or unequal
78S&F for PVC (SWR) reducers
79S&F for 75 mm PVC (SWR) vent cowl
80M&L for concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and supports, complete all as specified and directed.
81S&F for 150mm bore, PVC (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, laid in trenches or in floors complete all as specified and directed.
82M & L for Construction of Septic Tanks for 10 users conventional type LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc.
83M & L for Soakage wells of size 1.2m dia X 3.0 m effective depth in excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size
84Supply and laying , connecting and testing galvanised iron medium grade water tubing of size 20mm bore with all fittings and fixtures (ISI marked) confirming to IS:1239 laid in trenches or fixed on wall or in any position including necessary saddles and iron clamps complete of following sizes :- Note: Rates quoted includes for necessary scaffolding arrangement.
85Supply and laying , connecting and testing galvanised iron medium grade water tubing of size 25mm bore with all fittings and fixtures (ISI marked) confirming to IS:1239 laid in trenches or fixed on wall or in any position including necessary saddles and iron clamps complete of following sizes :- Note: Rates quoted includes for necessary scaffolding arrangement.
86Supply and fix gun metal gate valve of 20 mm boreconfirming to IS : 778/1980 CL-1 with iron wheel head screwed both ends for iron pipe of following sizes:
87Supply and fix gun metal gate valve of 25 mm boreconfirming to IS : 778/1980 CL-1 with iron wheel head screwed both ends for iron pipe of following sizes:
88Cutting existing cast iron / GI pipe of 40mm in position for insertion of tee/nipple/gate valve of 25mm bore including fittings viz tee, collar, bend or tail piece etc, complete all as specified & directed.
89Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.
90Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed.
91Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
92S & F Steel pipe glavanized grade of 40 mm core laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers complete ass as specifed.
93Supply,install and testing water heater storage type(Geyser)single phase 230V,50Hz ,5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion ,vertical installation type, 25 Litre capacity,2000Watt rated power,consist of safety valves,thermal cut off, thermostat including connecting up fixed to walls by drilling of holes ,grouting of bolts of suitable size with nuts etc and making good disturbed surface complete all as specified & directed.
94S & F Tubes medium grade galvanized 15 mm dia with fittings such as socket, bend and fixed complete to walls and ceilings all as specified.
95Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable in replacement of old unsv point wiring, 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and in including modular pressed steel sunken boxes of required size with modular cover plate with frame for mounting modular switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to disturbed surface and pointing in using cement mortar 1:3 all as specified and as directed.
96All as per ser item No 95 hereinbefore but for one 3 pin socket outlet 5 Amp same board.
97All as per ser item No 95 hereinbefore but for one 3 pin socket outlet 5 Amp independent.
98All as per Item no 95 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 4 Sqmm two single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
99Supply and fixing of modular switch single pole one way 6 Amps 1 module complete all as specified and directed.
100Supply and fixing of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
101Supply and fixing of modular switch single pole one way 16 Amps 1 module complete all as specified and directed.
102Supply and fixing modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
103Supply and fix of Ceiling rose surface bakelite three terminals 240 volts complete, all as specified.
104Supply and fix of Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,all as specified.
105S&F LED lamp,6500K,900lm in white colour of 9 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. Make: Havells/Philips or equivalent.
106S&Fof LED tubelight fitting 1x20Watt batten type fitting 4 feet long aluminium extruded housing IP-20 rated rated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hz system wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, system lumen efficacy 100 lm /watt ,CCT 6500K complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75 sqmm 3 core all as specidfierd and directed.
107S & F of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
108S&F of Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 8 ways, complete all as specified.
109S&F of MCB SP-06 to 32 Amp, 240 volts complete all as specified.
110S&F of MCB SPN-40-63 Amp, 240 volts 50Hz AC supply, complete all specified.
111S&F of Exhaust Fan metallic body, 300mm(12\\") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.Make: Havells/Bajaj/Crompton
112Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
113Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Nil during AOCNote:- Tenderers shall not quote for this Schedule Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56200596
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.67 Lakhs
LAST DATE 18-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Toilet Block (02 X Bathrooms, 04 X Water Closet And 02 X Wash Basin For Troops At Hq 06 Sect Rr, Potha Under Age (I) Cif (R)
Basic Detail
Tender No AGE(I)/R-26/2026-27
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 27 Jun 2026
Submission Date 18 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 9.67 Lakhs
Tender Fee 500
EMD 19340
Exemption Available
Document List
BOQ_867596.xls
e0d33155-d329-4407-99e4-2332b86b0fd3.html
TenderDocuments26.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_867596.xls

html

e0d33155-d329-4407-99e4-2332b86b0fd3.html

pdf

TenderDocuments26.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders