| Sl. No. | Item Description |
| 1 | Demolition of cement concrete of any description and in any position(above/below of ground level) not otherwise specifically provided as in sunken floor, plinth protection, roof kerb, foundation etc. all as specified and directed. |
| 2 | M&L for waterproofing treatment to sunken floors with application of two components acrylic modified cementious coating with glass fabric sheet between coats and one coat of primer (SIKA Top Seal-107 / Brush Bond FOSROC / Dr. Fixit / STP / CICO ) on dried surface free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrats must be prepared mechanically using abrasive blast cleaning or milling to remove cement laitance existing coating and achieve a gripping clean dry and free from laitance profile. The application instructions of manufacturer should be followed strictly. Note : (a) Chipping out any visible cracks must be clean and filled with SIKA latex SBR 100 Putty / Dr. Fixit 302 SBR latex / Perma latex SBR / FOSROC Nitbond SBR latex / Asain Paint latex in \\"V Groove\\" pattern and finally clean surface with powder grinder, wire brush hair brush & Vaccum pressure. (b) The waterproofing coating should be done upto a height of 450mm above the FFL on vertical surfaces.(c) Second coat shalll be applied after 6-8 hrs of application of previous coat and in the right angle direction. (d) All traps in sunken slabs to be enclosed with PCC 1: 11/2 :3 type B-0 (using 12.5mm graded crushed stone aggregate) (min 150mm) alround. |
| 3 | M&L for rendering 15mm thick in CM 1:4 in sunken portion of slab using waterproofing compound all as specified and directed Note : Water proofing compound shall be measured and paid separately. |
| 4 | Supply only liquid water proofing compound. |
| 5 | M&L for PCC 1:5:10 type E2 (using 40 mm graded crushed stone aggregarte) as in filling, foundation and mass concrete in sunken floor complete all as specified and directed. |
| 6 | M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base for receiving the floor finishes complete all as specified and directed. |
| 7 | Roughing the surface of old concrete floor picking sweeping clean and washing down with water to remove dust/mud etc.and applying a coat of Nitobond SBR cement slurry (1 Vol of Nitobond SBR + 1 vol of Water + 3 vol of cement) water proofing coating on roof complete all as specified and directed. |
| 8 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding averaging thickness of 50 mm complete all as specified. |
| 9 | M&L APP based polymeric membrane minimum weighing 3 kg/ Sqm and minimum 3mm thick, reinforced with polyster non woven fabric (weight not less than 150 gms/ Sqm) laid on applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m by forced application with butane torch over entire roof area with minimum overlaps of 100mm at the sides/ longitudnal edges of strips membrane and 150mm at the ends and sealed in after cleaning surface complete all as specified and directed and all as per manufacturer's instructions. |
| 10 | S&F for prepartion of new surface and applying two coats of aluminum paint on APP membrane complete all as specified and directed. |
| 11 | M&L for ceramic glazed dark shade coloured tiles of size 450x300x7mm thick joint free on and including 10mm thick screed bed in CM(1:4) set and jointed in neat cement slurry and pointed in coloured cement mixed with pigment to match the colour of tiles on vertical surfaces of wall as in skirting/ dado and dismantling of existing tile complete all as specified. |
| 12 | M&L for non skid dark coloured ceramic tiles 7 to 8 mm thick joint free (square/rectangular) area of each tile exceeding 0.11 sqm to 0.18sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or clolured cement to match including 15 mm thick screed bed in CM 1:4 including dismantling of existing tile complete all as specified. |
| 13 | M&L for green marble work 16-18 mm thick (table rubbed and polished) in steps, jambs, pillars window cills, cooking platforms, stair case and like in cement mortar ( 1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 15 mm thick screed bed in CM 1:4 including dismantling of existing marble with screed complete all as specified and directed. (The green marble shall be laid in single piece only, no joint will be provided). |
| 14 | M&L for non skid dark coloured ceramic tiles 7 to 8 mm thick joint free (square/rectangular) area of each tile exceeding 0.18 sqm not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match including 15 mm thick screed bed in CM 1:4 including dismantling of existing tiles complete all as specified. |
| 15 | M& L for dark or light coloured vitrified tiles10 mm thick, double charged joint free (square/rectangular) area of each tile n exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match including 15 mm thick screed bed in CM 1:4 including dismantling of existing tiles complete all as specified and directed. |
| 16 | M&L for 75mm thick cement cocnrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection finishing the surface even and fair complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges using WPC complete all as specified and directed.(Note : WPC shall be measured and paid for separately). |
| 18 | Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, complete all as specified and directed |
| 19 | M&L for brick work with fly ash bricks old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 20 | M&L for brick work with fly ash bricks old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 21 | M&L for repairing of RCC projections, chajjas, roofs, facia etc. by chipping off existing loose, damaged concrete and applying two coats of polymer modified cementitious mortar by welding mesh on epoxy bond coat on dry sub strate & free from debries / dust surfaces of concrete complete all as specified and directed by the manufacturer. (Note: - Cost of formwork and welded mesh shall be deemed to be included in unit rate quoted by the Contractor). |
| 22 | M&L for rendering 15mm thick ready mix mortar of approved makes on brick or concrete surfaces of walls, finished surface even and fair including taking down cement plaster of any description complete all as specified and directed. |
| 23 | M&L for rendering 12mm thick ready mix mortar of approved makes on brick or concrete surfaces of walls, finished surface even and smooth without using extra cement including taking down cement plaster of any description complete all as specified and directed. |
| 24 | M&L for rendering 5mm thick ready mix mortar of approved makes on ceiling finished surface even and smooth without using extra cement including taking down cement plaster of any description complete all as specified and directed. |
| 25 | M&L for preparation of newly plastered surface and applying two coats of cement base paint on wall surface complete all as specified and directed. |
| 26 | M&L for preparation of newly plastered surface and applying two coats of oil bound distemper on plastered surface of wall on priming coat complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surface and applying three coats of white wash on wall complete all as specified and directed. |
| 28 | M&L for preparation of new plaster surface and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for complete removing of existing treatment from wall / ceiling by using mechanical sander/grinder and applying 1 to 1.5mm thick acrylic damp proof wall care putty as per manufacturers instructions complete all as specified and directed. |
| 30 | M&L for preparation of puttied wall / ceiling by mechanical sander/grinder and applying two coats of oil bound emulsion distemper over a coat of primer complete all as specified and directed |
| 31 | M&L for preparation of puttied wall / ceiling and applying two coats of 100% premium exterior acrylic emulsion paint of apex ultima or equivalent having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade company depot tinted with silicon additives complete all as specified and directed. |
| 32 | M&L for preparation of old plastered surfaces of ceiling by brooming down, making good holes, cracks, etc and applying one coat of white wash incl cleaning the floor/ joinery surfaces, glass panes complete all as directed by Engr-in-charge |
| 33 | M&L for preparation of old plastered surface of walls rubbing down, making good holes, cracks and stopping etc on existing distempered surfaces and applying one coat of oil bound emulsion distemper on wall incl cleaning the floor/ joinery surfaces, glass panes complete all as directed by Engr-in-charge |
| 34 | M&L for preparation of old plastered surface of walls rubbing down, making good holes, cracks and stopping etc on existing distempered surfaces and applying one coat of cement base paint on wall incl cleaning the floor/ joinery surfaces, glass panes complete all as directed by Engr-in-charge. |
| 35 | M&L for preparation of old plastered surface of walls by brooming down, making good holes, cracks etc applying one coat of white wash on wall incl cleaning the floor/ joinery surfaces, glass panes complete all as directed by Engr-in-charge. |
| 36 | S&F steel window box type made of ERW tube hollow P section of size 60mmX25mm double rebated outer frame comprising double shutters i.e. guaged skelton & glazed, shutter frame of ERW tube P section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and FI 2mm thick welded/ screwed to frame for fixing of wire gauge including MS guard bars, fittings and fixtures welded to frame/ shutters as given below and all as shown on drg No. CEJZ/TD-1020/08 Sh 1/3 to 3/3 completeincl two coat of painting incl taking down old existing window :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Painting with one shop coat of zinc chromate primer. (Note: Wire cloth, glass shall be measured and paid for separately). |
| 37 | S&F steel window/ ventilator box type made of ERW tube hollow P section of size 60mmX25mm outer frame (single rebated) comprising glazed skelton shutter frame of ERW tube P section including MS guard bars, fittings and fixtures welded to frame/ shutters all as shown on drg No. CEJZ/TD-1019/08 Sh 1/3 to 3/3 including Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts, painting with one shop coat of zinc chromate primer incl two coats of painting incl taking down old existing window/ventilator complete all as specified and directed. (Note: Glass/ wire cloth shall be measured and paid for separately). |
| 38 | S&F anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 39 | S&F anodised aluminium door shutters, aluminium section weighing average not less than 1.00kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos of 150mm length in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 40 | S&F anodised aluminium window/ ventilator shutters side hung type without sash bars, aluminium section weighing average not less than 0.75 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) handle (1 no.) 150mm long complete all as specified and directed. |
| 41 | S&F aluminium anodised grill of 5mm thick (transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing window frame with suitable aluminium channel and CP brass / stainless steel screws @ 200mm centre to centre including cutting the grill to proper opeing size for fixing and operation of handles and fixing approved anodised aluminium standard section alround the opeing complete all as specifed and directed. |
| 42 | S&F 4.8mm thick black sheet glass ordinary quality in squares or rectangular not exceeding 1.00 sqm in each pane in aluminium door or window shutter complete all as specified and directed. |
| 43 | S&F in repair 4.8mm thick black sheet glass ordinary quality in squares or rectangular not exceeding 1.00 sqm in each pane in aluminium door or window shutter incl rubber packing, anodised aluminium snap beading complete all as specified and directed. |
| 44 | S&F of 4mm thick aluminium composite pannel (ACP) sheet for aluminium door/window complete all as specified and directed. |
| 45 | S&F in repair 4mm thick aluminium composite pannel (ACP) sheet for aluminium door/window complete all as specified and directed. |
| 46 | Petty repair to existing in built aluminium door, locks, hinges incl necessary making the lock/glass/ adjusting shutter complete serviceable all as per existing pattern as directed by Engineer-in-Charge incl provision of duplicate keys all as directed by Engineer-in-Charge. |
| 47 | S&F in repairs mortice lock, aluminium vertical type size 65mm 2 levers complete all as specified and directed. |
| 48 | S&F in repairs aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 49 | S&F in repair floor door stopper 140 mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 50 | Repairs, easing & adjusting of shutter without taking down shutters of any description exc 1.00 sqm & nexc 2 sqm each. |
| 51 | Taking down chowkats with shutter n.exc 1.50 Sqm each (without taking off shutter from the chowkats) complete all as specified and directed. |
| 52 | Taking down chowkats with shutter exc 1.50 Sqm but n exc 4.00 sqm each (without taking off shutter from the chowkats) complete all as specified and directed. |
| 53 | Taking down shutter of any description exc 1.00 Sqm but n.exc 2.00 Sqm each complete all as specified and directed. |
| 54 | S&F pressed steel frame for doors with one or more rebate including necessary fixing lugs, hings, lock strike, plate etc complete of size 105x60mm all as spd including two coats of painting over a coat of primer and filling back side with PCC 1:3:6 type-B-1 (using 12.5mm graded crushed stone aggregate) in the frames complete all as specified and directed. |
| 55 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 56 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppyling & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 57 | S&F 30 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels on both side complete all as specified and directed. |
| 58 | S&F 2nd class hard wood glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc. but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8 clause 8.24 (a) complete all as specified and directed. |
| 59 | S&F factory made WPC door frame of size 45 x 70mm, single extruded comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per specification of the manufacturer and as specified and directed by Engineer-in-Charge. |
| 60 | S&F 30 mm thick factory made natural fiber composite door shutter with CNC cutting of required size having minimum 40% high strength plant derived fibers, consisting of thermoset polymers, non-toxic additives ( minimum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum, modules of elasticity (3-4), screw withdrawal strength of 1800 N (Face) & 900 N (Edge), having interlaminar shear strength and thermal stability complete all as per manfacturer's instructions as specified and directed by Engineer-in-Charge. |
| 61 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack/wooden beads, or galvanised wire staples complete all as specified and directed. |
| 62 | S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 63 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putting in squares nexc 0.50 Sqm each complete all as specified and directed. |
| 64 | S&F in repair 4mm thick sheet glass ordinary quality and glazing with oil putty in squares nexc 0.50 Sqm each incl hacking out of old broken glass panes from wooden or steel frame complete all as specified and directed. |
| 65 | M&L for preparation of new wooden surface exc 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 66 | M&L for preparation of newly steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 67 | S&F in repair 300mm, mild steel ordinary rat tail rod pattern springs, including roller and roller plate joint through welding/ bolt in metal/wooden frame to be carried out complete all as specified and directed. |
| 68 | S&F aluminium anodized barel tower bolt of extruded section 150mm long ISI marked complete all as specified and directed. |
| 69 | S&F aluminium alloy handle fabricated type anodized of size 150 mm long ISI marked complete all as specified and directed. |
| 70 | S&F 100mm size butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 through bolt or with screw complete all as specified and directed. |
| 71 | S&F aluminium alloy, anodised, sliding door 300 mm long ISI marked bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 72 | S&F in repair drapery rod in any length, high strength stainless steel pipe having outer dia 28mm with a pair of brakets of any shape/design complete all as specified and directed. |
| 73 | S&F in repair 18/19 mm thick one side prelaminated colour WPC board for cup board shutter and frame & fixed at site complete alll as spcecified and directed. (Note : Board edges properly fixed with teak wood beading). |
| 74 | S&F aluminium alloyed handle fabricated type anodized of size 100 mm long complete all as specified and directed. |
| 75 | S&F 75mm size hasp and staple safety type aluminium anodised brass with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and directed. |
| 76 | S&F in repair 3-4 mm thick UV marble sheet wall panelling printed inclusive of adeshive to fixed at site with tipper strip weather proof, water proof, termite proof including all C and U type section with matching of panelling fixing at border of panelling and complete all as specified and directed by Engr-In-Charge. |
| 77 | S&F in repair, 7-8 mm thick PVC hollow panelling consisting of wood grain printed PVC sheet inclusive of solvant cement and fixing at site on PVC frame formed by sticking high density EPS, flame retardent (TF) grade, heavy duty with tipper strip weather proof, water proof, termite proof including all C, U type and like PVC section with matching of panelling fixing at border of panelling and complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F 4mm thick e board false ceiling (classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 x 605 mm fixed with 1.6mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia adjustable J hook consisting of two nos washers and two nuts at 1.2mtr centre size of main tee 38x 25 x 1.4mm, cross tee 38 x 25 x 1.4mm, angle along with walls 38 x 25x 2.00mm including taking down existing boards of any thickness including cover fillets etc complete all as specified and directed. |
| 79 | S&F 500 ltr capacity rotational moulded polyethylene 3-layer white water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postition all as specified in SSR Part I including dismantling of water tanks complete all as specified and directed. |
| 80 | S&F 1000 ltr capacity rotational moulded polyethylene 3-layer white water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postition all as specified in SSR Part I including dismantling of water tanks complete all as specified and directed. |
| 81 | S&F 2000 ltr capacity rotational moulded polyethylene 3-layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postition all as specified in SSR Part I including dismantling of water tanks and removing to store, complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F in repair ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore complete all as specified and directed. |
| 83 | S&F in repair stop valve 20mm bore cast copper alloy with butterfly handle screwed down for high pressure, screwed on both ends, fixed with iron pipe etc complete all as specified and directed. |
| 84 | S&F in repair stop valves or angle valve cast copper alloy 15mm bore fancy type chromium plated alloy with butterfly handle screwed down for high pressure, screwed on both ends, fixed with iron pipe etc complete all as specified and directed. |
| 85 | S&F in repair bib taps cast copper alloy 15mm bore fancy type chromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 86 | S&F in repair pillar taps, cast copper alloy fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore and fixed. |
| 87 | S&F in repair brass chromium plated shower rose fancy type 125mm size with swivel joints, any size, including fixing to steel pipe or union with brass CP arm 195mm long, 15 mm size complete all as specified and directed. |
| 88 | S&F in repair brass chromium plated tubular towel rail 20mm dia, D type, 60 cm long with flanges complete all as specified and directed by Engr-in-Charge. |
| 89 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified as directed |
| 90 | S&F in repair 15 mm brass CP WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 91 | S&F in repairs vitreous china wash down water closet (pedestal pattern) fixing with bolts ,white colour, incl stainless steel L-type jet spray with 1 m hose pipe, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. incl seat cover complete including making good to floor complete all as specified and directed. |
| 92 | S&F in repair vitreous china squatting pan “Orrisa Pattern” white of size 580x440mm with internal foot rest with `P’ or `S’ trap, integral foot rest including water connection to trap and flushing pipe etc complete and bedding in PCC 1:7:12 type F-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. |
| 93 | S&F in repair vitreous China wash hand basin, with pedestal white flat back, size 550x 450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets and coupling complete all as specified and directed. |
| 94 | S&F in repair vitreous China table top wash hand basin, white rectangular bowl, size 550X400X140mm excluding taps but including coupling complete all as specified and directed. |
| 95 | S&F in repair vitreous china urinal, half stall type, white (excluding flushing cistern) white with grating, waste coupling and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screw, pointing aroug urinal back in cement, grating and union for discharge pipe incl PTMT waste coupling, waste pipe, urinal spreader complete all as specified and directed. |
| 96 | S&F in repair vitreous china coloured WC Italian finish pedestal pan with attached vitreous china flushing cistern (monolithiic type) of push button type having duel flushing cistern of same colour including pvc seat cover same colour including CP Jet chromium plated with PVC connection 15mm bore complete all as specified and directed. |
| 97 | S&F in repair vitreous china counter top oval wash basin, white, size 550x400mm including waste coupling and waste pipe complete all as specifed and directed. |
| 98 | S&F in repair vitreous china urinal partition white of size 310x700 mm fixed with wall by steel screw complete all as specified and directed. |
| 99 | S&F in repair PVC low level duel flushing cistern 10ltr capacity, with syphonic, action PVC float valve, brackets and 32mm bore PVC flush pipe etc complete all as specified and directed. |
| 100 | S&F in repair PVC waste pipe 32mm dia 800mm to 1200 mm long fixed to wash hand basin and sink all as specified and directed. |
| 101 | S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 102 | S&F in repair grating doom 100 mm dia with waste hole, complete all as specified and directed. |
| 103 | S&F in repair stainless steel L-type jet spray with 1m hose pipe for fitting in WC complete all as specified and directed. |
| 104 | S&F GI tubing 15mm bore medium grade, fixed to wall/ ceiling or floor etc with all fittings including taking up and down complete all as specified and directed. |
| 105 | All as per Srl item No 104 above but fixing only (old serviceable pipe be reused). |
| 106 | S&F GI tubing 20mm bore medium grade, fixed to wall/ ceiling or floor etc with all fittings including taking up and down complete all as specified and directed. |
| 107 | All as per Srl item No 106 above but fixing only (old serviceable pipe be re-used). |
| 108 | S&F GI tubing 32mm bore medium grade, fixed to wall/ ceiling or floor etc with all fittings including taking up or down old pipe complete all as specified and directed. |
| 109 | Dismantling of cast iron, PVC or SGSW drain pipes, jointed in cement mortar and taking out of trenches all as specified and directed by Engineer-in-Charge. |
| 110 | S&F PVC (SWR) pipes 110mm dia in any length with rubber ring joint fixed to wall/floor upto 12m height complete all as specified and directed. |
| 111 | S&F PVC (SWR) pipes 75mm dia in any length with rubber ring joint fixed to wall/floor upto 12m height complete all as specified and directed. |
| 112 | S&F in repair PVC (SWR) bends 110mm dia, in any radius, complete all as specified and directed. |
| 113 | S&F in repair PVC (SWR) bends 75mm dia, in any radius, complete all as specified and directed. |
| 114 | S&F in repair 110mm bore PVC(SWR) branch pieces (single T), single (equal or unequal ), ordinary or inverted or with parallel branches with oval access door complete all as specified and directed. |
| 115 | S&F in repair 75mm bore PVC(SWR) branch pieces (single T), single (equal or unequal ), ordinary or inverted or with parallel branches with oval access door complete all as specified and directed. |
| 116 | S&F in repair PVC vent cowl of size 110mm. |
| 117 | M&L in repair for PVC(SWR) floor trap plain including jointing with solvent cement 100mm dia complete all as specified and directed. |
| 118 | M&L in repair for PVC(SWR) floor trap plain including jointing with solvent cement 75mm dia complete all as specified and directed. |
| 119 | S&F in repair stack clamps (110 mm pipe) made out of 20x 1.5mm galvanised mild steel incl stays, bolt and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 120 | S&F in repair stack clamps (75 mm pipe) made out of 20x 1.5mm galvanised mild steel incl stays, bolt and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 121 | S&F beveled edge mirror of selected quality 5mm thick glass fancy type, size as required, fixed to wall with chromium plated brass screws studs and cup washers incl making hole in wall incl demolition of old existing mirror complete all as specified and directed by Engr-in-charge. |
| 122 | S&F in repair 600mm X 450mm beveled edge mirror of selected quality glass 5mm thick fancy type as approved by GE and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 123 | M&L for pre cast cement concrete louvers and jali made of cement concrete1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in jali 25 mm thick set in CM (1:4) including taking down existing jali complete all as specified and directed by Engineer-in-Charge. |
| 124 | M&L for cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 125 | M&L for 60 mm thick, M-35 grade PCC interlocking tiles rubber moulded and chemical coated glossy finished of size and shape as approved set, jointed, and pointed neat cement slurry with grey cement and pigments, joints will be filled with fine sand including demolition of existing tiles, complete all as specified and as directed.(Note : Sand will be paid under relavent item). |
| 126 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge. |
| 127 | M&L for vitrified designer heavy duty parking tiles, exterior grade, size 400 x 400 mm, 12mm thick, coloured, with 15mm thick in cement mortar 1:6 for laying floor finished, set, jointed and pointed in neat cement slurry with white cement and pigment as in path / floor, pattern of tiles as approved by GE complete all as specified and directed. |
| 128 | S&F machine cut kota stone slab flooring 18 to 20mm thick over cement screed base 20mm thick in 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (with bees wax polish) including demolition existing complete all as specified and directed by Engineer-in-Charge. |
| 129 | Dismantling of asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed. |
| 130 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick, ISI Marked of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls fixed with self tapping screws as specified. |
| 131 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Weather boarding/ridge/cladding to wall fixed with self tapping screws as specifierd |
| 132 | Dismantling framed work of timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 133 | S&F of rolled mild steel Gde Fe-410-W Gde E-250 Quality-A in roof trusses (framed), trussed, purlins crane gantries, joist, channel, steel tube, rails & fastenings & heavy brackets framimg (beam, tee, angle, coulmn, gusset plates, channel, hollow square/rectangular or flat section) including distance pieces, cleats with riveted, bolted or welded attachment etc. complete all as specified and directed by Engr-In-Charge. |
| 134 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed |
| 135 | Demolition of RCC of any description upto 12m height all as specified and directed by Engr-in-charge. |
| 136 | Form work to rough finished surface of concrete flat to soffits of shelve, chajja, fins etc including supports over hangs etc. |
| 137 | S&F 6mm dia and over TMT bar cut to length bent to shape including cranking binding spirraly, hooping, hooking end and binding with MS wire (anealed) not less then 0.9 mm dia or securingwith clips as specified and directed. |
| 138 | M&L for RCC 1:2:4 type B-0(using 12.5 mm graded crushed stone aggregate) as in chajjas facia, shelves etc and similar work all as specified and directed. |
| 139 | S&F vinyl wall paper of approved shade/design over wall with adhesive all as per manufactures instruction incl removing of existing complete all as specified and directed. |
| 140 | Taking down existing unserviceable rolling shutters of any type exc 2 sqm not exc 4 sqm area and refixing the same in situ after necessary welding work, oiling and greasing, replacement of unserviceable bearings, realignment of anchoring rod, checking and made functional / operate able all moving strips/ parts to the entire satisfaction of the engineer in charge complete including replacing of damaged strips all as specified. (Note :- (i) Strips shall be measured & paid separately as supply only under appropriate item. (ii) Rates are deemed to inclusive of all civil works required for refixing and making good the disturbed surfaces). |
| 141 | S&F safety lever locks mild steel with 4 levers for rolling shutters fixed in repairs complete all as specified and directed by Engineer -in-Charge. |
| 142 | S&F in repair stainless steel cockroach trap with hole, round 101mm dia complete all as specified and directed |
| 143 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof/ wall coverings complete all as specified and directed by Engineer-in-Charge. |
| 144 | S&F in repair aluminum, 0.56 mm thick plain, sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood /steel/concrete framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required complete all as specified and directed by Engineer-in-Charge. |
| 145 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit Rs. 91,624/- from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail