Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #56200583

Tender For Repair And Maintenance To Internal Electrification Work In Certain Bldgs In Hq 10 Sector And 29 repair renovation Under Age (I) Cif (K)

Issued by Statutory Bodies & Commissions/Committees · Srinagar, Jammu and Kashmir
Tender Value
10 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
8 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance To Internal Electrification Work In Certain Bldgs In Hq 10 Sector And 29 repair renovation Under Age (I) Cif (K)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 08-Jul-2026 Date Date 21-Jul-2026

BOQ

Name of Work:- REPAIR AND MAINT TO INTERNAL ELECTRIFICATION WORK IN CERTAIN BLDGS IN HQ 10 SECTOR AND 29 RR UNDER AGE (I) CIF (K)
Sl. No. Item Description
1Taking down copper /aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches , ceilling roses , holder , tube light , bulk head , pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be made as per conditions separately) and making good surfaces , wall, floors etc.)
2M& L in replacement of Point wiring for one light point / fan point or bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed, FRLSH, Multistranded copper conductor cable as in and including non metalic rigid PVC concealed conduit ISI marked, not less than 20mm dia, mediun duty including sunken steel boxes of suitable size with 3mm thick plastic laminated backelite sheet including FRLS PVC insulated unsheathed multistranded copper conductor cable of size 1.5sqmm (green colour ) as continious earth wire and connecting to earth dolly, and making good to distrub surfaces of wall/floor to match to existing finishes etc complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
3All as per Srl item No 2 here in before but wiring with FRLSH, Multistranded copper conductor cables in PVC Casing and caping.Note : Rates are deemed to be including providing PVC accessories i.e Tee, elbow, socket etc.
4M& L in replacement of Point wiring for one socket outlet 5 Amp 3/5 pin for independent board etc controlled by one switch with copper conductor cable FRLSH type multistrand of size 1.5 Sqmm(red or yellow or blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of appropriate size not less than 20mm dia,and with sunk cast iron for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified.
5All as per Srl item No 4 here in before but for one 3 pin 5 amps socket outlet independent board in PVC casing & caping all as specified and directed.Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.
6All as per Srl item No 4 here in before but for one 3 pin 5 amps socket outlet on the same board with other switch.
7All as per Srl item No 4 here in before but for one 3 pin 5 amps socket outlet on the same board in PVC casing & caping all as specified and directed.Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc.
8All as per Srl item No. 4 above but for one 15 Amp independent socket outlet point using 4.0 Sqmm FRLSH PVC insulated unsheathed multi-strand copper conductor cable drawn in including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia,medium duty including sunken steel boxex of suitable size with 3mm thick plastic laminated bakelite sheet including FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly .
9All as per Srl item No 8 here in before but for 15 Amp socket outlet in PVC casing & caping all as specified and directed.Note: Rates are deemed to be including providing PVC accessories i.e Tee,elbow,socket etc. casing/caping
10All as per Srl item No. 8 above but for metal plug top AC & Geyser point using 4.0 Sqmm FRLSH PVC insulated unsheathed multi-strand copper conductor cable drawn in including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, incl FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly .
11M & L in replacement for Switch piano flush button single pole one way 6 Amps 240 volts with polycarbonate body complete all as specified and directed.
12M&L in replacement for Bell push switch piano flush button single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and directed.
13S&F in replacement for multi socket outlet for 2 &3 pin, 6A, flush type complete all as specified and directed.
14S&F in replacement of socket outlet 2 in 1, 3 pin, 6 and 16 Amps , flush type, single pole, one way, 230Volts complete all as specified and directed.
15S&F in replacement of switch piano, flush type, single pole, one way, 16 Amps 230Volts complete all as specified and directed.
16S&Fin replacement for stepped type electronic mini fan regulator 100 watt rotary step all as specified and directed.
17M&L for modular point wiring for one light/fan/bell point controlled by one switch complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed ,FRLS , multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete all as specified and directed by Engineer-in-Charge.
18Description all as per srl item No. 17.00 here-in-before but for 5 pin 5 Amps socket outlet on independent board controlled by one switch 5 Amps one way, complete all as specified and directed.
19Description all as per srl item No. 17.00 here-in-before but for 5 pin 5 Amps socket outlet on same board controlled by one switch 5 Amps one way, complete all as specified and directed.
20Description all as per srl item No. 17.00 here-in-before but for 15 Amps socket outlets point using 4.00 Sqmm FRLS PVC insulated multistranded copper conductor cable including 4.0 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable as earth wire complete all as specified and directed.
21M&L in replacement for one Module switch 1 way 10 Amps 240 volts all as specified and directed.
22M&L in replacement for one Module switch 1 way 16 Amps 240 volts all as specified and directed.
23M&L in replacement for Moduler bell push 6A, 240 volts 1 Module all as specified and directed.
24M&L in replacement for Modular socket 6A, 240 volts 2/3 pin 2 Module all as specified and directed.
25M&L in replacement for Modular socket 6A/16A , 240 volts 2/3 pin 2 Module all as specified and directed.
26M&L in replacement for Modular Fan step regulator 100W , 240 volts 1 Module all as specified and directed.
27M&L in replacement for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body.
28M&Lin replacement for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
29M&L in replacement of LED bulb 12 watt 230 Volt all as specified and directed.
30Supply & fix in replacement of wall mounted 1x20 watt LED 6500K tube light fittings (4 feet long), decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
31Supply and fixing in replacement of LED light fittings mirror type with high out put diffuser 2 feet, 10 watt 220 volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
32S&F in replacement of LED Bulk Head luminaries 10W complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ.
33S&F in replacement of Bell, Ding Dong AC. 230 volts, single pole all as specified.
34S&F in replacement of sheet metal enclosure single pole and neutral 240 volt , 20 Amps with two pin and earth plug and socket plug top complete with single pole MCBs all as specified and directed.
35Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs single door single pole and neutral with 200 amps rated bus bar of 2- way, 240 volts complete all as spd and directed.
36Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 4- way, 240 volts complete all as spd and directed.
37Supply and fix in replacement of old unserviciable Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 8- way, 240 volts complete all as spd and directed.
38Supply and fixing in repair MCB single pole and nuetral 40 Amps, 240 volts , B-series complete all as specified and directed.
39Supply and fixing in repair MCB single pole 6 to 32 Amps, 240 volts , B-series all as specified and directed.
40M&L for Earthing complete with galvanised steel earth plate electrode 600mmx600mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated complete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected, complete all as specified & directed. Note:- 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted by the contractor.2. Soil should be free from stone, boulders, aggregate, gravels etc
41M & L for sub main wiring with 10.0 sqmm copper conductor cable multistrand, FRLSH PVC sheathed two run (as phase and neutral) and one run 10.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in existing surface /recessed steel/ PVC conduit complete all as specified and directed by Engr-in-charge.,
42S & F in replacement (including taking down old fitting) LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
43S&F in repair octane LED panel of 15 W 6500K round slim,compact, aluminium die cast edge lit panel, recessed mounted round fixture with opal diffuser and separate electronic driver and low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output.
44S&F in repair octane LED panel of 15 W 6500K square slim, compact, aluminum die cast edge lit panel, recessed mounted square fixture with opal diffuser and separate electronic driver and low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output.
45S&F in replacement of old u/s service cable size 10 sqmm twin core multistranded fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with aninner sheathing of PVC tape armoured with galvanised steel wire of 4mm dia or tape and overall PVC sheathed complete all as specified and directed.
46S&F in replacement of old u/s service cable size 16 sqmm twin core multistranded fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with aninner sheathing of PVC tape armoured with galvanised steel wire of 4mm dia or tape and overall PVC sheathed complete all as specified and directed.
47S&F \\"as in repair prewired\\" VTPN Distribution board with provision for MCCB as incommer 100 A 04 pole IP 54 ,04way(for incomming MCCB & outgoing MCBs), with copper busbar for each phase, with Neutral bar, Earth bar and cable ties for cable managemet, fully insulated busbar & shrouded Neutral bars, with 100 Amps MCCB, 25 KA, 4 pole, as incomer and SP MCB's of cap 6-32amps as outgoing complete all as specified and as directed. Note: Rate of MCCBs and MCB,cutting,chasing,grouting in wall are included in above rate.
48Note :- An amount of Rs. Rs 27,746.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56200583
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance To Internal Electrification Work In Certain Bldgs In Hq 10 Sector And 29 repair renovation Under Age (I) Cif (K)
Basic Detail
Tender No AGE (I) CIF (K) - 33/2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 08 Jul 2026
Submission Date 21 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
BOQ_867963.xls
c93b8399-7b9e-4ded-8a51-bc58e42f2581.html
Tender33.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_867963.xls

html

c93b8399-7b9e-4ded-8a51-bc58e42f2581.html

pdf

Tender33.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders