| 1 | Supply, fixing and errection of Steel tubular swaged poles type 410 SP-31 09 Mtr metres long, weight not less then 154 Kgs, ISI marked conforming to IS:2713-1980, complete with accessories such as cast iron base plate, finial taper plug, bolts, nuts & screws, washers and drilling of holes for continuous GI earth wire as specified inluding applying with two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking out old unsv pole complete all as specified and directed.Note:-Necessary excavation and foundation are measured and paid separately. |
| 2 | Dasmantling of cables, all accessories such as junction box, street light, service connection cables, clamps etc. without any damage from existing pole and taking out the pole carefully and shifting of pole 09 mtr long including refixing all accessories from one place to another place as directed by engr-in-charge and errection at new place. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth complete all as specified and directed. Note:-Necessary excavation and foundation are measured and paid separately. |
| 3 | M&L in replacement of earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed. |
| 4 | Excavation in trenches in hard/dense soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed. |
| 5 | Excavation in trenches exceeding 1.50m wide and exceeding 1.50m in depth and getting out in for hard/dense soil, all as specified . |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed. |
| 7 | Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, all as specified . |
| 8 | M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed. |
| 9 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core including taking down old cable, complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per ser item No 10.00 here in before but 16 Sqmm 4.0 core |
| 12 | All as per ser item No 10.00 here in before but 10 Sqmm 2.0 core |
| 13 | M&L for replacement of Off load change over switch 63 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr in Charge. Make: Havells cat no IHBFFE0063 or as per site requiremnt |
| 14 | M&L for replacement of Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr in Charge. Make: Havells cat no IHBFFE0100 or as per site requiremnt |
| 15 | S&F in replecement of MCB SP 6 to 32 Amp, 240 volts complete all as specified. |
| 16 | S&F in replecement of MCB SPN 32-40 Amp, 240 volts 50Hz AC supply, complete all specified. |
| 17 | M&L for replacement and testing moulded case circuit breaker (MCCB), adjustable Thermal and fixed magnetic type, 4 Pole, 415 volts, 50Hz, breaking capacity 36KA, rating 63 Amp, complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 18 | M&L for replacement and testing moulded case circuit breaker (MCCB), adjustable Thermal and fixed magnetic type, 4 Pole, 415 volts, 50Hz, breaking capacity 36KA, rating 100 Amp, complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 19 | M&L for replacement of GI bracket for fixing of street light fittings bend to shape, made out of 40/50 mm dia GI pipe medium grade suitable for fixing of Light upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 20 | M&L for replacement of junction box hot press moulded SMC of inside dimension size 333 x 233 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar 4 strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amp MCB SP, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed. Make- Sintex GSJB3020 |
| 21 | M&L for replacement of wiring with two nos single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into steel pole for connection to security lights from junction box fitted on pole complete all as specified and as directed by the Engineer in charge. |
| 22 | S&F Copper cable 1.5 Sqm 3 core PVC sheathed multi core for connection of street light inserting from top in side the pole and connecting in junction box complete and making Hole in Pole as per Site including taking down old cable, all as directed by Engineer-in-Charge |
| 23 | M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of pole around pole all as specified and as directed by Engineer-in-Charge. |
| 24 | M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation/bed pit of pole all as specified and as directed by Engineer-in-Charge. |
| 25 | M & L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundation of pole around pole and for road filling all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 26 | M & L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundation of pole around pole and for road filling all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |