Tender For Provision Of Parking Shed For 10 Type ‘A Specialist Vehicles In installation Sardar Patel (Para 35 Sanction) Under Ge (Navy) Porbandar
Tender Value
4.71 Crore
Estimated cost
Bid Submission
03 Aug 2026
31 days left
EMD
6.48 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Parking Shed For 10 Type ‘A Specialist Vehicles In installation Sardar Patel (Para 35 Sanction) Under Ge (Navy) Porbandar
BOQ
| Sl. No. | Item Description |
| 1 | SCH 'A' PART-I : \\"(SITE CLEARANCE AND DEVELOPMENT INCL DEMOLITION)\\" brought forwarded from Serial Page No.25 |
| 2 | SCH 'A' PART-II: \\"(BUILDING AND STRUCTURES WORKS)\\" brought forwarded from Serial Page No. 26 |
| 3 | SCH 'A' PART-III: \\"(INTERNAL ELECTRIFICATION)\\" brought forwarded from Serial Page No. 27 |
| 4 | SCH 'A' PART-IV: \\"(FIRE FIGHTING AND FIRE ALARM SYSTEM)\\" brought forwarded from Serial Page No. 28 TO 31 |
| 5 | SCH 'A' PART-V: \\"(EXTERNAL ELECTRIC SUPPLY)\\" brought forwarded from Serial Page No. 32 |
| 6 | SCH 'A' PART-VI: \\"(EXTERNAL WATER SUPPLY)\\" brought forwarded from Serial Page No. 33 |
| 7 | SCH 'A' PART-VII: \\"(CHAIN LINK FENCING)\\" brought forwarded from Serial Page No. 34 to 35. |
| 8 | SCH 'A' PART-VIII: \\"(AREA DRAINAGE)\\" brought forwarded from Serial Page No. 36. |
| 9 | SCH 'A' PART-IX \\"(SEWAGE DISPOSAL)\\" brought forwarded from Serial Page No. 37 to 38. |
| 10 | SCH 'A' PART-X \\"(ARBORICULTURE)\\" brought forwarded from Serial Page No. 39 |
| 11 | SCH 'A' PART-XI \\"MISC WORKS\\" |
| 12 | BUILDING AND STRUCTURES WORKS |
| 13 | M&L for development of lawn area on roof an planning of natural grass or any other approved grass approved by GE including watering, shaping etc complete all as specified |
| 14 | INTERNAL ELECTRIFICATION |
| 15 | Supply and fix Highbay 120 Watt luminaries with pressure die-cast housing, integrated PC optics and 150 lm/W e cacy. 4 kV in-built and 10 kV external surge protection. IP66 ingress protection with additional safety chain in all respect all as specified and directed. |
| 16 | FIRE FIGHTING AND FIRE ALARM SYSTEM |
| 17 | Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). |
| 18 | Fire extinguisher Mechanical foam type, 9.0 Ltr ISI marked (IS:15683) complete in all respects including initial fill and wall suspension brackets |
| 19 | ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity Each 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 20 | ABC (Powder Type) Fire Extinguisher 6 Kg In HP Mild Steel Cylinders Each ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono) Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:1349-1993 |
| 21 | Supplying, laying, testing and commissioning of cabling for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed, flexible, 2 core x 1.5 sq mm armoured cable as per specifications complete all as specified and as directed. |
| 22 | Supply and fixing of fire point made of MS angle, MS sheet as suitable size and including fixing arrangement. The fire point shall be consists with the following items to be provided with no extra cost:(i)Hook - 03 Nos(ii) Fire bucket with handle - 01 Nos |
| 23 | EXTERNAL ELECTRIFICATION |
| 24 | S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of following size 40/32 mm outer/inner dia of conforming to IS 16205 Part -24 including necessary bends, coupling tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /equivalent as approved by GE |
| 25 | Supply, installation, Testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 Volts, AC, 50 Hz outdoor type, floor mounted, free standing, dust and vermin proof, air, ventilation with IP-54 protection fabricated out of 3.15 mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for MCCB/metering equipments/ cavble galley etc, Ammeter, Digital type, with suitable CTs, Digital voltmeter and ammeter, including locking arrangement all as specified and directed by Engineer-in-Charge(a) 300Amps rated cooper bus bar with colour coded heat shrinkable sleeve-01 Job(b) MCCB 160Amps 415V 25KA 4 Pole-1 No (Main Hammer)(c) MCCB 63 Amps 415V 16 KA 4 Pole -4 No |
| 26 | CHAIN LINK FENCING |
| 27 | S&F for PVC coated GI chain link fencing panel jali with 4mm dia GI wire, size 75mm x 75mm of aperture, fitted along all side angle flat iron and fixing with main vertical steel/ RCC post of fencing including cutting welding drilling etc complete all as specified and directed. Note: Fencing post, MS flat Iron and foundation concrete, excavation painting etc will be paid separately |
| 28 | ARBORICULTURE |
| 29 | Supply and lay sweet earth (Black soil) brought from outside MD land to a uniform thickness of 15cm including watering, spreading and levelling complete all as directed. |
| 30 | Supply, mix and lay farm yard manure for proper plantation complete all as specified and directed |
| 31 | M & L for development of lawn area and planning of carpet grass or any other approved grass as approved by GE including watering shaping etc. complete. |
| 32 | S&F water sprinklers of brass rotating type standard quality suitable for 15mm dia GI pipe complete all as specified and directed by Engineer in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 31 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender