| 1 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete. |
| 2 | M & L for PCC 1:3:6 type C2 ( using 40 mm graded stone aggregate) as in foundation filling mass concrete complete all as specified and as directed. |
| 3 | Supply & Fix mild steel angles flat iron, bars, flats wind ties for roof including securing bolts, posts and struts in fencing etc including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting, etc. and similar work confirming to Fe-290 Gde E-165 complete.all as specified and directed. |
| 4 | S&F PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.50 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm Complete all as specified and as directed. |
| 5 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes and heavy bracket framing (beam,tee,angle,channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality A complete all as specified and as directed. |
| 6 | S&F mild steel bolts with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm long n.exc 10 cm long dia metre of neck exceeding 11 to 15 mm complete all as specified and as directed. |
| 7 | M&L for preparing new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified and as directed. |
| 8 | Excavation in trenches n exc 1.5m wide and not exceeding 1.50m and getting out in hard/dense soil complete all as specified and as directed |
| 9 | M & L for cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation, filling mass concrete complete all as specified and as directed. |
| 10 | M & L for RCC M-30 design mix concrete (using 20 mm graded stone aggretate) as in foundations incl rafts, footings and mass concrete complete all as specified and as directed |
| 11 | M & L for RCC M-30 design mix concrete (using 20 mm graded stone aggretate) as in retaining walls and the like any thickness above top of footing including attached pillasters and butteresses complete all as specified and as directed |
| 12 | M&L for use and removal of steel form work to sides of concrete foundations, footings,rafts and raft beams sides and soffits of foundation and plinth beams and similar work for flat surface complete all as specified and as directed. |
| 13 | M & L foe Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 14 | S&F TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and as directed. |
| 15 | M&L for broken stone or boulders including hand packing (any thickness) at back side of weep holes and raising or lowering to the required level complete all as specified. |
| 16 | Return filling in Surplus soil and back filling of retaining wall, including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and as directed |
| 17 | Removing excavated soil n.exc 50 m and depositing where directed at level n.exc 1.50 m above the starting point complete all as specified and as directed. |
| 18 | M&L for PCC solid block masonry wall with PCC blocks Type C1 1:3:6 (using 20 mm graded stone aggregates) , set in CM 1:4 complete all as specified and as directed. |
| 19 | Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in Hard/dense soil complete all as specified and as directed. |
| 20 | M&L for 150mm thick hard core of guage n.exc.63mm using broken stone aggregate spread, levelled, watered and rammed to a true surface complete all as specified and as directed. |
| 21 | M & L for Pre-cast PCC block masonry type B-1 (1:2:4) with solid block and set in CM1:6, complete all as specified and as directed. |
| 22 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and as directed, |
| 23 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including prepartion and applying priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacestc complete all as specified and as directed by Engr-in-Charge |
| 24 | S&F PVC (SWR) pipes 110 mm bore in any length with rubber ring joints fixed to walls /weep holes complete all as specified and directed |
| 25 | S&F 110mm PVC (SWR) bends any radius with access door Complete all as specified and directed as directed. |
| 26 | S&F MS steel work in tubular, trusses incl purlins, special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade 240 Complete all as specified and as directed. |
| 27 | S&F MS works as in wind ties for roof including securing bolts etc complete all as specified. |
| 28 | M&L for plates of plain or chequered, square cut or notched of steel welded to steel structure for base plate etc. complete all as specified and as directed. |
| 29 | M&L for prepainted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 30 | M&L for prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 31 | S&F Stainless Steel railing, (SS 316 grade) of safety railing consists of vertical and horizontal bars of thickness not less than 2.0mm, welded to base plate , MS plate, maintenance free, corrosion resistant, aesthetic looking stainless steel extruded sections complete all as specified and as directed by Engineer-in-charge. |
| 32 | Dismantling wrought iron or mild steel of any description not otherwise provided for complete all as specified and asdirected. |
| 33 | S&F Roof Trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, Tee, Angle, Channel or Flat section) including distance pieces, cleats etc conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed. |
| 34 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed |
| 35 | Dismantling of CGI/PGI sheet in Roof covering complete all as specified and as directed. |
| 36 | S&F Plain, Aluminium sheeting 0.56mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)all as specified and as directed. |
| 37 | M & L for painting with two coats of oil bound distemper over a coat of primer on old plastered or untreated surfaces of walls including nesessary preparation of surfaces complete all as specificed and as directed by Engineer-in-Charge. |
| 38 | Taking down chowkats or frames but exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed |
| 39 | S&F Anodised aluminium frame for doors, windows, ventilators and Partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 40 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 41 | M&L for Aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge |
| 42 | S&F Aluminium composite panel sheet of 3 to 4 mm thick as in wall cladding & false ceiling,Chajja including aluminium frame work with plastic strips ( double sided sticker) of suitable size of varying thickness of 10mm to 30 mm , applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant, The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed. |
| 43 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed. |
| 44 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified and as directed. |
| 45 | S&F Aluminium (extruded section ) Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed, complete all as specified and as directed. |
| 46 | S & F Aluminium alloy, anodised, sliding door bolt with hasp & staple (Bolt type) 300mm long and fixing clips of sheet, cast or extruded section and fixing bolt of cast aluminium alloy, complete all as specified and as directed by Engineer-in-charge. |
| 47 | S & F Aluminium, anodised, barrel tower bolt of extruded section, 150 mm long, complete all as specified and as directed by Engineer-in-charge. |
| 48 | S & F Aluminium alloy anodised handle, 150 mm long extruded fabricated type, complete all as specified and as directed by Engineer-in-charge. |
| 49 | S&F Butt hinges of size 100 mm medium weight cold rolled mild steel complete all as specified and as directed. |
| 50 | S&F in Repairs aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed |
| 51 | S&F Sheet glass 4.0mm thick ordinary quality and glazing with oil putty in Square exc 0.5 sqm in each pane complete all as specified and as directed. |
| 52 | Dismantling any type of Floor or Wall tiling including cement mortar bedding (but not backing) and removing rubbish out side of the MD Land complete all as specified and as directed by Engineer-in-Charge. |
| 53 | M&L for Cement concrete type B-1,1:2:4, 25mm thick (20mm gradedaggregate) in levelling course complete all as specified and as directed. |
| 54 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular)area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 55 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular)area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in skirting/dado in neat cement slurry and pointed in white or coloured cement with pigment to match over 10mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 56 | Taking down PVC waste ,vent,rain water pipes incl fittings in any position complete all as specified and as directed. |
| 57 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floors. Complete all as specified and as directed. |
| 58 | M & L for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturers instructions:- (i) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (ii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iii) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane.Note :- Water proofing compound shall be measured and paid separately. |
| 59 | M&L for water proofing treatment to sunken surfaces of the slab in following sequences:- (a) Slope correction by using 1:2:4 (Nominal Mix) concrete minimum 25mm thickness at one end and a slope of 1:20 by using 12.5 mm graded stone aggregate with integral water proofing Chemical PIDI PROOF-LW mixed in proporation 200ml /50 Kg cement of DR Fixit of Pidilite Industries Ltd or STP No 1 (liquid) of STP Ltd in proporation 200ml / 50 Kg cement or equivalent as per manufacturer instructions complete. |
| 60 | (b) PCC padding with cement concrete 1:1.5: 3 type A 0 (using 12.5 mm graded stone aggregate) 25mm thick with integral water proofing compound \\"Dr Fixit\\" manufactured by M/S Bouchemic or equivalent as per manufacturer instructions complete incl providing spout pipe of 50 mm as required. |
| 61 | (c) Vertical sides plastered in CM 1:4, 15mm thick with WPC @ 3 % by wt of cement and sunken portion to be filled(ponded) with water and tested for 7 days after required period of curing to observe leakages/seepages, if any,shall be arrested by pressure grouting and retested till leakages/seepages are completely stopped.(Note :- WPC will be Measured and paid Separately) |
| 62 | (d) After ponding test the surface shall be dried and sides of sunken slab shall be treated with two coats proof coats black manufactured by M/S Dr fixit or equivalent as per manufacturer instructions all over and testing again for water tightness by ponding of water for 72 hours complete. |
| 63 | (e) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. |
| 64 | (f) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. |
| 65 | (g) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. |
| 66 | (h)M&L for 25 mm thick PCC 1:3:6 type C2 using 40mm graded aggregate as in Mass concrete in sunken treatment. |
| 67 | (i)M&L for 50 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate as in top surface after sunken treatment. The joints in CI/GI/PVC pipes, Nahani traps,WC, P/S traps shall be made leak proof. The gap around pipes in walls/beams shall be properly filled and sealed with water proof joint fillers. |
| 68 | (j) M&L for PCC 1:5:10 type E2 using 40mm graded aggregate as in Mass concrete in sunken treatment. Please Enable Macros to View BoQ information |