Tender For Repair/Maint Including Cleaning Of Sewage Line, Manholes, Gully Traps, Floor Traps, Nahani Trap And Cleaning Of Blockage From Wc, Gt, Mh Etc In Dhiman, Joshi, Single Living Officers Accn, Guest Houses, Offrs Mess, Saroj And Ghuman Colony,
Tender Overview
Project Description
Tender for Repair/Maint Including Cleaning Of Sewage Line, Manholes, Gully Traps, Floor Traps, Nahani Trap And Cleaning Of Blockage From Wc, Gt, Mh Etc In Dhiman, Joshi, Single Living Officers Accn, Guest Houses, Offrs Mess, Saroj And Ghuman Colony, Benjamin In Domestic Area At Af Stn Utarlai.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition and breaking up 150mm dia drain pipes (salt glazed ware,AC or reinforced concrete) set in cement mortar all as specified and as directed. |
| 2 | All as per item No 01 above but 200mm dia pipe all as directed. |
| 3 | All as per item No 01 above but 300mm dia pipe all as directed. |
| 4 | Excavation in trenches not exc.1.50m wide and not exc 1.5m deep for foundation n.exc 10 sqm or manhole pire hole or laying of sewer pipe etc and getting out in soft/loose soil as directed. |
| 5 | All as per item no 04 above but deepth exc 1.5m but nexc 3.00m all as specified and as directed. |
| 6 | M&L for beding to drain pipes including packing under, and hunching in PCC 1:3:6 type C2 using 40 mm graded aggregate against the side of 150mm SWG/NP2 pipes after they are laid and tested for following dia bore pipe all as specified and directed. |
| 7 | All as per item No above but 200mm dia pipes all as directed. |
| 8 | All as per item No above but 300mm dia pipes all as directed. |
| 9 | M&L for 150 mm bore Reinforced concrete pipe class NP2, laid and jointed complete with collars all as specified and directed. |
| 10 | All as per item No above but 200mm dia pipes all as directed. |
| 11 | All as per item No above but 300mm dia pipes all as directed. |
| 12 | Retunning filling in including spreading,levelling,watering and well ramming in layers n.exc 25 cm . |
| 13 | Removing excavated materials not exc. 50m and depositing where directed. |
| 14 | Demolition of Brickwork or stone/boulder masonry/PCC BLOCK masonary built inlime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed. |
| 15 | M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6 complete. |
| 16 | M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate)as in foundation filling and mass concrete all as directed. |
| 17 | M&L for providing precast cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) set in cement mortar 1:4 as in cover slab supported on wall complete all as specified and directed |
| 18 | M&L rendering 15mm thick cement plaster on fair faces of brick surface/concrete surfaces in CM 1:4. |
| 19 | S&F MS steel TMT bars 6mm to 8mm dia and over cut including 10mm dia cut to length ,bent to shaprequired including cranking bending for hooping for column ,hooking ends and bindings with and including mild steel wire (annealel)not less than 0.9mm dia. |
| 20 | M&L cement concrete Type B1 1:2:4 (20mm graded aggregate) as in copping all as directed. |
| 21 | Cement concrete (1:2:4) type B-2 (using 40mm graded aggregate) in benching of manhole including finishing the top of benching even and smooth using extra cement. |
| 22 | Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permice. |
| 23 | M&L 25mm thick PCC 1:2:4 type B1 (20mm graded aggregate) as in levelling course. |
| 24 | 15mm thick Screed bed or bedding layer of morter for laying floor finishes CM 1:6. |
| 25 | M&L for Non- skid Ceramic coloured tiles (Degital series) 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in- Charge |
| 26 | M&L glazed ceramic coloured tiles (Degital series) 450x300mm x 7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of CM 1:4 10mm thick etc all as specified and directed by Engineer-in Charge |
| 27 | Taking up or down 15mm dia steel tubing and connection including cleaning for refixing or removal to store all as directed. |
| 28 | -do- all as per tem No 27 above but 20mm dia. |
| 29 | S&F 15mm dia Steel tubing medium grade Galvanised with all fittings and fixed complete to wall and ceiling or laid in floors all as directed. |
| 30 | -do- all as per tem No 29 above but 20mm dia. |
| 31 | S & F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixifng bolts flushing cistern and flush pipe) incl plastic water closets seat cover fix to wall as specified and directed by Engr-in-charge. |
| 32 | S&F in repair low level flushing cystern 10 ltrs capacity bbody moulded from virgin quality high impact poly propoliyone and functional parts moulded from engneelicy grade ABS nylon and nylon glan complete incl brackets and 1`5mm bore 450mm long PVC connection all as directed by Engr-in-charge. |
| 33 | S&F PVC water connection 600 mm long to wash basin of 15mm dia including CP nuts and washers all as specified and as directed by Engineer-in-Charge.. |
| 34 | S&F in repairs vitreous china squatting pan 'Orissa pattern size 580x440mm white with integral foot rest (excluding, flushing cistern and flush pipe) squatting pan including connection 'P' trap and to flushing pipe complete. |
| 35 | M&LSalt-glazed stoneware gully traps 125x100mm, square or round mouthed, tvpe 'P' all as directed. |
| 36 | Cleaning of manhole of size 600mm to 1000mm depth by bailing out water taking out sludge & removing the sludge out side M.D land complete.NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES ANY CLEANING WILL HAVE TO DONE BY JETTING AND SUCTION IS MANDATORY |
| 37 | All as per Item No. 39 above, but for manhole of size 1000 to 2000 mm depth complete.NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES ANY CLEANING WILL HAVE TO DONE BY JETTING AND SUCTION IS MANDATORY |
| 38 | All as per Item No. 39 above, but for manhole of size 2000 to any depth in completeall as specified and directed.NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES ANY CLEANING WILL HAVE TO DONE BY JETTING AND SUCTION IS MANDATORY |
| 39 | Cleaning of blocked kitchen sink including removing and refixing the grating in same position with cement mortar. |
| 40 | Cleaning of blocked gully trap including removing and refixing the grating in same position with cement mortar. |
| 41 | Cleaning of blocked WHB including removing and refixing the grating in same position with cement mortar. |
| 42 | Cleaning of blocked EWC. |
| 43 | Cleaning of blocked IWC. |
| 44 | Cleaning of nahani trap. |
| 45 | Sewage lines cleaning of size 150mm and over including maneholes through super sucker machine which have both function jetting and suction and have water tank capacity min 4000ltr and dump tank ca[pacity min 8000ltr and root type blower capacity 5900 cubic metre per hour operated high preassure suction per cum jetting sewage cleaning machine capacity including skilled operator supervising Engineer for cleaning/partial desilting of manholes upto any depth and sewer line as guide lines laid in IS-11972 (1987) and complete cleaning of size all as directed by Engineer-in-Charge. NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES. |
| 46 | Sewage lines cleaning of size 200mm and over including maneholes through super sucker machine which have both function jetting and suction and have water tank capacity min 4000ltr and dump tank ca[pacity min 8000ltr and root type blower capacity 5900 cubic metre per hour operated high preassure suction per cum jetting sewage cleaning machine capacity including skilled operator supervising Engineer for cleaning/partial desilting of manholes upto any depth and sewer line as guide lines laid in IS-11972 (1987) and complete cleaning of size all as directed by Engineer-in-Charge. NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES. |
| 47 | Sewage lines cleaning of size 300mm and over including maneholes through super sucker machine which have both function jetting and suction and have water tank capacity min 4000ltr and dump tank ca[pacity min 8000ltr and root type blower capacity 5900 cubic metre per hour operated high preassure suction per cum jetting sewage cleaning machine capacity including skilled operator supervising Engineer for cleaning/partial desilting of manholes upto any depth and sewer line as guide lines laid in IS-11972 (1987) and complete cleaning of size all as directed by Engineer-in-Charge. NOTE:-MAKING A PATHWAY IF REQUIRED AT ANY PLACE FOR MOVEMENT OF JETTING MACHINE AND DUMP TAK IS INCLUSIVE IN THE RATES. |
| 48 | S&F SS Grating square 150mm size (minimum wt. 100 gms) |
| 49 | S&F in repair 32mm dia PVC flexible waste pipe for WHB/Sink, length 60 to 100cm complete all as specified and directed. |
| 50 | S&F in repair 40mm dia PVC flexible waste pipe for WHB/Sink, length 60 to 100cm complete all as specified and directed. |
| 51 | S&F in repair cast iron floor trap,nahani traps 75 mm outlet dia, with grating including jointing to waste pipe fixed in cement concrete type B -1, 1:2:4 complete all as specified. |
| 52 | All as per item No. 51 above but 100mm dia of outlet for WC's without grating complete all as specified and directed. |
| 53 | S&F in repairs branch pieces single 'T' 100 mm bore equal or unequal with oval access door |
| 54 | S&F in repair 75 mm bore cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured). |
| 55 | S&F in repair 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured). |
| 56 | S&F in repairs 100 mm CI connection socket to fit out let of WC |
| 57 | S&F in repair 100 mm bore cast iron bend (any radius) with / without duck’s foot or heel rest. |
| 58 | Dismantling and breaking up drain pipes, (Cast iron or reinforced concrete) 75 mm (internal dia) set in cement mortar . |
| 59 | Dismantling and breaking up drain pipes, (Cast iron or reinforced concrete) 100 mm (internal dia) set in cement mortar . |
| 60 | S&F cast iron soil, waste and vent pipes of 75 mm bore in any length with or without ers, with cement joints, laid in trenches or in floors or fixed to walls as specified & as directed. |
| 61 | S&F cast iron soil, waste and vent pipes of 75 mm bore in any length with or without ers, with cement joints, laid in trenches /floors fixed to walls complete all as specified and directed by Engineer-inCharge. |
| 62 | S&F in repair 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including dismantling of old pipe complete all as specified and directed by Engineer-inCharge. |
| 63 | S&F in repair 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including dismantling of old pipe complete all as specified and directed by Engineer-inCharge. |
| 64 | S&F in repair PVC (SWR) 75 mm bends any radius complete all as specified and directed by Engineer-inCharge. |
| 65 | S&F PVC (SWR) 110 mm bends any radius complete all as specified and directed by Engineer-inCharge. |
| 66 | S&F PVC (SWR) junction single, (Single T) equal or unequal of any radius complete all as specified and directed by Engineer-inCharge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender