| 1 | Taking down cement or cement lime plaster, any descriptionon on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removal of debris to out side Mil Stn, complete all as specified and directed. |
| 2 | M&L for rendering 15mm thick on fair faces of brick or stone work or concrete surfaces in CM 1:6 and finishing the surface even and fair without using extra cement complete all as specified and directed. |
| 3 | M & L for 15mm thick rendering in CM 1:4 on surface other than fair face of brick or stone masonry/concrete surfaces, mixed with water proofing liquid @ 2% by weight of cement and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note :- Water Proofing shall be measured and paid separately) |
| 4 | Supply only intergal Water Proofing complete all as specified and directed. |
| 5 | M&L 10mm thick rendering in cement mortar 1:3 on fair faces as in ceiling surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finishing the surface even and fair without using extra cement, complete all as specified and directed. |
| 7 | Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. and also applying one coat of anti corrosion paint to visible reinforcement if any. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slurry with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each using shot gun or pressure nozzle for grouting the surface well bonded with reinforcement (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces etc., complete all as specified and directed. Note: The rate will be inclusive of scaffolding for single/double/ tripple storey, complete all as specified and directed. |
| 8 | M&L for applying two coats of oil emulsion distemper on newly plaster surface of walls (tint as approved by Engr-in-Charge) with sponge roller, including preparation of surfaces and priming with alkali resistant priming paint on avg 1-2mm thick wall care putty complete all as specified and directed. |
| 9 | M & L for preparing new ceilings surfaces and applying three coat of white wash on ceilings complete all as specified and directed. |
| 10 | M & L applying two coats of cement based paint incl cement primer on newly plastered or unplastered wall surface including preparation of surfaces,complete all as specified and directed. |
| 11 | M&L for preparation of old surfaces plastered or unplastered of wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying a coats of white or colour wash on old deco or undecorated walls, complete all as specified and directed. |
| 12 | M & L for preparing old or previously treated ceilings surfaces by brooming down or with steel wire brushes, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying a coat of white wash on ceilings complete all as specified and directed. |
| 13 | M & L for preparing of old wall surface and applying a coats of cement based paint, complete all as specified and directed. |
| 14 | M & L for preparing old or previously treated walls surfaces by brooming down or with steel wire brushes, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying a coat of oil bound distemper on walls with sponge roller including filling holes with required qty of putty complete all as specified and directed. |
| 15 | M & L for preparing old or previously treated walls surfaces by brooming down or with steel wire brushes, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of oil bound distemper with sponge rollers including filling holes with required qty of putty complete all as specified and directed. |
| 16 | M&L complete removal of existing treatment by mechanical means of old wall surfaces and applying two coats of distemper oil emulsion, with sponge rollers and applying wall care putty of avg 1-2mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 17 | Material and labour for exterior painting work including complete removal of existing treatment and rubbish material till top surface of existing plaster and crack filling with crack seal upto 3mm where required and making good/smooth the surface with exterior grade wall care putty with silicon additives and sanding the surface for removal of loose particles and applying one coat of smartcare waterproof primer on old wall and new wall plastered surfaces and chajjas with 10% of dilution of water and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal and fungal properties (tint as approved by GE) , complete all as specified and directed. Note- All treatment shall be done by applicator authorized by original equipment manufacturer with any mechanical means spray gun /roller. |
| 18 | M & L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed . |
| 19 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 20 | Dismantling of corrugated or plain steel sheeting of any gauge thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 21 | Supply & fixing galvanized corrugated mild steel sheeting 0.50mm thick with two corrugations side lap fixed with L-type or J type hooks and washers, in roof, walls etc. with grade of zinc coating 275 gm complete all as specified and directed. |
| 22 | All as per item No. 21 above but except sheet., complete all as specified and directed. |
| 23 | Supply & fixing galvanized plain mild steel sheeting 0.50mm thick as in ridges, hips, valley gutters, drip and straight flashings with grade of zinc coating 275 gm complete all as specified and directed. |
| 24 | M&L for preparation New/Old galvanised surfaces to receive painting, by coating with mordant solution ncluding washing and cleaning of any description not otherwise described over 10 cm width or girth and applying Two coats of synthetic enamel paint inlc priming coat as in roof complete all as specified and as directed. |
| 25 | M&L for preparation of old painted brick, stone, concrete or plater surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified and directed. |
| 26 | M & L for preparation of old floor surfaces over 10cm in width or girth including cleaning the surfaces by wire brushes and washing and applying a coats of terracotta colour acrylic antifungal exterior emulsion painting on floor of PCC Chequered tiles, complete all as specified and directed. |
| 27 | M & L for writing letters, figures, index, arrows etc not exc 15cm in height using 1st quality synthetic enamel paint of colour as directed on walls incl obliterating old writing any description with paint to match existing work completed all as specified and directed. |
| 28 | S&F of 3mm thick sheet glass ordinary quality and glazing type, n.exc. 0.5 sqm in each pane, duly fixed with oil putty or wooden beading as required incl hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surround, glazed with putty or fixed with beads, complete all as specified and directed. Note: The rate will be inclusive of scaffolding for single/double/ tripple storey. Please Enable Macros to View BoQ information |