| 1 | Dismantling of posts or struts (wood, steel or RCC) any section, embedded in concrete / brick work, masonry etc. including taking out embedded portion and making good disturbed surfaces all as directed. |
| 2 | Dismantling fencing wire mesh / chain link fencing any type all as specified. |
| 3 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, sub base for flooring etc all as specified. |
| 4 | M&L for mild steel work in hand rails, nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 5 | Supply only chain link mild steel galvanized fencing, any size or type all as specified. |
| 6 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, mild steel round bar etc complete all as specified. (Note:Chain link fence & MS round bar shall be measured and paid separately in relevant items as supply only). |
| 7 | Supply only 10 mm dia mild steel round bar as in line wires for chain link fencing complete all as specified. |
| 8 | M&L for preparation of newly or previously untreated steel and iron surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer all as specified. |
| 9 | S&F in repairs galvanized 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc all as specified. (Note: Each line wire to be measured) |
| 10 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles including removal of debris from site to outside MoD land. |
| 11 | Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water including removal of debris from site to outside MoD land. |
| 12 | M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 mtr mean radius using old size bricks built in cement mortar (1:6) all as specified. |
| 13 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces including finishing surface even and smooth without using extra cement all as specified. |
| 14 | M&L for prepration of newly plastered surface of wall and applying two coats of cement base paint all as specified. |
| 15 | M&L for preparation of old painted surfaces of cement concrete kerb stones/ parapets etc and applying one coat of synthetic enamel paint complete all as specified. |
| 16 | S&F for concertina coil fencing with punched tape concertina coil of any dia, having 50 Nos rounds per 6 metre length (before stretching) on up to 3 mtr height of wall with ‘Y’ shaped angle iron brackets placed 2.4 mtr to 3.00 mtr apart, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron with reinforced barbed tape (R.B.T.)/ spring core (2.5mm thick) wire of high tensile strength of 165 Kg/ Sqcm with tape (0.5mm thick) and weight 43.478 Gm/ mtr complete all as specified including taking down existing rusted concertina coil fencing. (Notes: Angle iron as in post and struts shall be measured and paid separately under relevant items) |
| 17 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified. |
| 18 | M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 Gde E-165 all as specified. |
| 19 | Demolition of precast cement concrete louvres and jallies any type or in any position all as specified and as directed. |
| 20 | M&L for 35 mm thick precast cement concrete louvres and jallies in 1:2:4 nominal mix, type B-0 using 12.5 mm graded stone aggregate and set in cement mortar 1:4 (measured solid) including all mouldings but excluding frame (Note:Precast frame shall be measured and paid separately) |
| 21 | S&F for mild steel TMT bar 10 mm dia and over, cut to length and bent to shape and binding with and including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified. |
| 22 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girder, bressummers, lintels, cantilevers, shelves including supports, overhangs etc, complete all as specified. |
| 23 | M&L for periodical inspection, checking various parts, greasing and welding as required to make the sliding steel door/rolling shutters gear/hand operated/electrical opertaed for easy and smooth operation for mild steel sliding sliding door area not exc 11 Sqm at every three months interval all as specified. (Note: work will be done upto 12 mtr height from GL) |
| 24 | All as per item No. 23.00 above but collapsible gate area exc 5 Sqm but not exc 15 Sqm complete all as specified. |
| 25 | All as per item No. 23.00 above but rolling shutter gear operated and area not exc 16 Sqm complete all as specified. |
| 26 | All as per item No. 23.00 above but rolling shutter gear operated area 16 Sqm and not exc 24 Sqm complete all as specified. |
| 27 | All as per item No. 23.00 above but rolling shutter hand operated area not exc 16 Sqm complete all as specified. |
| 28 | Taking down rolling shutter (any size) and repair/ replacement of damaged parts of shutter including welding, oiling, greasing complete and re-fixing base in its original position and making good to disturb surface to match with existing specification including one coat of synthetic enamel paint complete all as specified. |
| 29 | Taking down collapsible gate and repair/ replacement of damaged rivet and other parts including welding, greasing and re-fixing base in its original position and making good to disturbed surface to match with existing specifications including one coat of synthetic enamel paint complete all as specified. |
| 30 | Taking down existing mild steel rolling shutter shaft 40 to 50 mm and repair/ replacement of damaged as required inlcuding cutting, welding, drillling holes and refixing the bearing and other mounted accessories for rolling shutter of any size all as specified and directed by Engineer-in-charge. |
| 31 | S&F in repair mild steel springs suitable for rolling shutter of any size complete all as specified and directed. |
| 32 | S&F repair rubber bushes suitable for rolling shutters of any size complete all as specified and directed. |
| 33 | S&F in replacement of ball bearing of designation 6205 to mild steel sliding door of size varing from 7'' to 9\\" dia complete all as specified. |
| 34 | S&F in replacement of ball bearing suitable for rolling shutters of any size all as specified and directed |
| 35 | S&F in repair gear worn for rolling shutters of diffrent sizes all as specified and directed. |
| 36 | S&F in repair gear box for rolling shutters of any sizes all as specified and as directed. |
| 37 | S&F in repair gear wheel for rolling shutters of any size 300 mm dia as required all as specified and as directed. |
| 38 | S&F in repair opertaing handle for rolling shutters all as specified and as directed. |
| 39 | S&F for rolling shutter lathes of 1.25 mm thickness including taking down damaged shutters slots (replacment of laths only) complete all as specified. |
| 40 | S&F in replacement of steel rolling shutter 1.25 mm thick laths without ball bearing as specified including top cover, anchoring road hasp and one shop coat of primer erected in position as indicated complete push pull or manual type and making good to match the existing surface all as specified. |
| 41 | All as per item No. 40.00 above but gear operated type with level gear box and crank handle all as specified. |
| 42 | S&F for collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified erected in position and securing runners with holdfasts and brackets including taking down existing collapsible steel gate complete all as specified. |
| 43 | Demolition of re-inforced cement concrete (reinforcement cut as requird to facilitate demolition) of any description and in any position not otherwise specifially provided for including removal of debris from site to outside MoD land |
| 44 | M&L for reinforced cement concrete in 1:2:4 (nominal mix) type B-1 using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.50 mtr span complete all as specified. Please Enable Macros to View BoQ information |