Tender For Repairs To Leakage/Seepage,Plumbing And Misc Works At Zone-I,Ii And Vi Of Various Units At Lekhapani Mil Stn Under Ge Dinjan No.2
Tender Value
17 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
11 days left
EMD
34000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repairs To Leakage/Seepage,Plumbing And Misc Works At Zone-I,Ii And Vi Of Various Units At Lekhapani Mil Stn Under Ge Dinjan No.2
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces and removing unserviceable materials from site of work complete all as specified and directed by the Engineer-in-Charge. |
| 3 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete fixed to frames all as specified and as directed. |
| 4 | S&F Solid PVC door frame for cupboard of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and as directed. |
| 5 | S&F 100mm butt hinges, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised & fixed to PVC door complete all as specified & as directed. |
| 6 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and as directed. |
| 7 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 8 | S&F providing factory made white colour 3- TRACK UPVC SLIDING WINDOW are made of UPVC extruded profiles with wall thickness of 2.3 mm ( + 0.2 mm ), Window profile with hollow section with multi chamber, Frame ( 109 mm x 52 mm ), Sliding sash ( 80 mm x 47 mm ), Sliding interlock ( One vertical length in each shutters ) ( 43.5 mm x 50.5 mm ), Glazing bead ( 22 mm x 4.5 mm ) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket,1.5 mm (+ 0.2 mm) thick, galvanized steel Frame ( 29 mm x 18 mm )2nos.,Sliding sash ( 28 mm x 17 mm ), Sliding mesh sash (29mmx13mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners. complete as per manufacture's specification and direction of Engineer-in-charge |
| 9 | Supply and fixing factory made uPVC white colour Two track two panels sliding glazed window upto 1.50m height made of (small series) frame 50 x 42.5 mm & sash 32 x 54 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.20 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with steel wire staplescomplete all as specified & directed. |
| 11 | Hacking out old broken glass (any thickness, size, quality or description), from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed. |
| 12 | S&F 3mm thick PVC transparent window panes ordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each pane complete all as specified and as directed |
| 13 | S&F 3mm thick PVC frosted window panes ordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each pane complete all as specified and as directed |
| 14 | S&F Door closer hydraulically regulated as in repair , aluminium body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg. Fixed to shutter and frame with steel wooden screws/ suitable welding complete as in repairs. |
| 15 | S&F Floor door stopper 140mm size doubled leged of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor as in repairs. |
| 16 | S&F MS chromium plated curtain rod 25 mm dia , with and including MS chromium plated decorative round finials on either end provide a visually balanced appearance including MS chromium plated brackets fixed to wall with 30 mm wooden steel screws and PVC rawl plug, anchors, and installation as in repairs complete. |
| 17 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 18 | M&L for second class hardwood, scantlings, wrought, fixed in unframed work complete as specified and directed. |
| 19 | Demolition of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 20 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from ceiling using 4mm GI rods, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge. |
| 21 | M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system duly suspended with 2 to 3mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips, hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions |
| 22 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 23 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 24 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50mm thick of an colour having tensile strength of 550Mpa as , AZ-150in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 25 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa, AZ-150 as in roof ridges etc. covering/cladding to wall, fixed with self tapping screws with bitiman washer complete all as specified and as directed |
| 26 | Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clan and washing down complete all as specified and as directed |
| 27 | M & L for rendering 15mm thick cement mortar 1:4 over Roof mixed with water proofing compound @ 3% weight of cement or manufacturer instruction finished even and smooth complete all as specified and as directed |
| 28 | M & L for applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed. |
| 29 | M&L taking down existing plaster at the junction of chajjas and wall over window chajja width not exc 60 CM and applying 15mm thick cement plaster in CM 1:4 mixed with WPC of Pidilite 101 of 200ML for 50 Kg of cement and applying two coats of Cement Base Paint with and including necessary preparation to match with the existing shade.Note : The Rate quoted shall be inclusive of necessary scaffolding upto double storied bldg. |
| 30 | M&L Forming V grooves in brick or RCC of 30mm deep and 20 to 30 mm wide on face and applying a primer coat of Pidilite 301 URP and filling the same with mixed with cement in proportion 1:1 |
| 31 | M&L taking down existing spout pipe and fixing 75 mm dia PVC SWR pipe of length 45 cm long of one side pin headed cutting and fixed in PCC 1:2:4 type B1 and making good the disterubed portion by rtendering 15 mm thick in CM (1:4) and applying two coatd of cement base paint over a coat of primer complete all as specified and directed |
| 32 | M&L taking down existing spout pipe and fixing 160 mm dia PVC SWR pipe of length 45 cm long of one side pin headed cutting and fixed in PCC 1:2:4 type B1 and making good the disterubed portion by rtendering 15 mm thick in CM (1:4) and applying two coatd of cement base paint over a coat of primer complete all as specified and directed |
| 33 | Demolition of cement concrete of any description and in any position not other wise specifically provided for complete |
| 34 | M/L Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge including necessary form work complete. |
| 35 | M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 36 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 37 | M&L for 50mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 38 | S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, fixed to walls as in repair complete all as specified and as directed. |
| 39 | S&F PVC (SWR) bends 110 mm dia any radius as in repair all as specified and directed. |
| 40 | S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 41 | S&F PVC (SWR) bends 75mm dia any radius as in repair all as specified and directed. |
| 42 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal from site, for bore of pipes 15mm dia complete all as specified and directed. |
| 43 | S&F 15mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed. |
| 44 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed. |
| 45 | S&F 20mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed. |
| 46 | S&F fancy type15mm dia Bib taps long body cast copper alloy, chromium plated screwed down to iron pipe or for brass ferrule & fixed complete in repairs, all as specified & directed. |
| 47 | S&FPVC High/Low level flushing cistern 10 litres capacity including all fittings i.e float valve, syphon, flush pipe, brackets in repairs all as specified and directed by EIC. |
| 48 | Repairs to flushing cistern to address the leakage by replacement of rubber gasket/ washers, complete all as specified and directed |
| 49 | Repairs to flushing cistern to replace the syphon complete all as specified and directed |
| 50 | Repairs to flushing cistern to replace flush handle complete all as specified and directed |
| 51 | S&F PVC connection 15mm size with PTMT nuts of length 600mm in repairs complete all as specified & directed. |
| 52 | Dismantling water tanks exc 250ltr but not exceeding 500ltr capacity complete all as specified and as directed. |
| 53 | Dismantling water tanks exc 500ltr but not exceeding 1000ltr capacity complete all as specified and as directed. |
| 54 | S&F rotational moulded polyethylene water storage tanks of 500 ltr capacity,(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I & as directed. |
| 55 | S&F rotational moulded polyethylene water storage tanks of 1000 ltr capacity,(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I & as directed. |
| 56 | S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified & as directed. |
| 57 | S&F Health Faucet with 1 Meter Long Easy Flex Tube in Chrome Finish and Wall Hook with N.R.V (Back Flow Preventer) with clamp in repair (Cat Part No. ALD-CHR-563 of Marc or equivalent of Jaquar) |
| 58 | Material and labour(Roof treatment) for providing plain cement concrete with filler 1: cement 1; sand 2: agregate 4 type B1 using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed.Note : (i) Minimum thickness of PCC shall be 30mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after(ii) PCC shall be laid to acheive true slope towards the drain/weep holes. |
| 59 | Material and labour (Roof treatment) for applying a coat of water proofing compound (1 part powder : 1 part liquid), of desired consistency with nylon brush @ 5 sqm/kg coverage over vertical/horizantal surface of RCC roof and parapet complete all as specified. |
| 60 | M&L Water Proofing: (Roof treatment)a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Bio wash.b) If online leackage found seal wih Bond coat.Open the cracks by making ‘V’ groove, filling cracks with Nano Crack Filler.c) Aplly carbon based shorter chain Bond Coat d) Providing and applying Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.e) If ant crack found open and fill the crack with carbon base filler and bond coat.and use nano wall filler to reduce the undulation.f) Apply Nano high penetration Bond coat two coat.g) Providing and applying Barrier Coat Paint/ Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat. |
| 61 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for sunken floor treatmentcomplete not more than 0.50 mtr Depth all as specified. |
| 62 | M&L Water Proofing: (sunken floor treatment)a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Bio wash.b) If onlinr leackage found seal with Bond coat.Open the cracks by making ‘V’ groove, filling cracks with Crack Filler.c) Aplly carbon baesed shorter chain Bond Coat d) Providing and applying Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.e) If ant crack found open and fill the crack with carbon base filler and bond coat.and use wall filler to reduce the undulation.f) Apply Nano high penetration Bond coat two coat.g) Providing and applying Barrier Coat Paint/ Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a -structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat. |
| 63 | M & L(sunken floor treatment) for PCC (1:5:10) type E2 using 40mm graded stone aggregate in foundations, filling and mass concrete, sunken floors complete all as specified and directed. |
| 64 | Material and labour(sunken floor treatment) for appplying NANO magic in sealing floor traps, waste pipes outlets from wall, etc |
| 65 | Surface Preparation 1. Concrete surface must cleaned with wire brush/grinder to remove loose mortar and must be smooth, uniform, clean and dust free to receive the treatment. Concrete profile should be in the range of CSP 3-4. Preliminary Treatment 2. Any crack, construction joints shall be treated with Polymer modified repair mortar/ SC General purpose grout by proper grooving arrangement [10 x 5 mm] as per manufactures recommendation. 3. Block work joints, Block wall -slab interface to be packed with Polymer modified repair mortar/ SC General purpose grout. Treatment to continue up to full Hight of the planter wall. 4. Angle fillet - Making coving (50X50mm) using M20 Grade Concrete integral waterproofing Vitalia NEO admixed with additive 200 ml per bag of cement as per manufacturer’s specification 5. Testing by ponding water for 24-72 hours to identify surface defects min. 25 mm-100 mm, a. First Ponding Test to be on Structural Slab, b.. Second Ponding Test after waterproofing Treatment, c. Third Ponding Test after Screed laying Bore packing (Treatment steps given separately) 6. If any leak/dampness observed post water ponding Test, it needs to be pressure grouted with SmartCare General Purpose Grout. 7. Skim tape to be provided wherever dissimilar material ( Steel, PVC ) encountered, to overlap the coating. |
| 66 | Damp Roof Ultra Application: - Supplying and applying High build elastomeric waterproofing coating membrane which id formulated with PU hybrid polymers and reinforcing acrylic polymers, Resists positive hydrostatic pressure of up to 10 bars, Effectively bridges cracks up to 2.5 mm, Reduction Provides surface temperature reduction up to 12 °C, Excellent resistance to water, UV rays and ageing, The consumption to be maintained is 10sqft/L Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer