BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of CGI/PGI Sheet fixed with screws as in roof covering complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 4 | Dismantling boarding, any description, fixed in any position with nails |
| 5 | Supply & Fixing 15 mm thIck 2nd class softwood boarding planed one side with butt joint with nails in any situation complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material & Labour weather boarding in 2nd class hardwood, clean swan, plain, 20 mm thick or feather edges, 15 mm to 20 mm thick and fixed with 30 mm laps joints complete all as specified and directed by Engineer-in-Charge. |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 8 | Demolition cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness below or above ground level with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 9 | Material & Labour for 75mm thick Cement concrete type C-2, 1:3:6 (20mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material & Labour for 25 mm thick PCC in Cement Mortar 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & Labour for Virified Ceramic tiles 10mm thick (square/rectangular) polished, (shade as approved by Engineer-in-charge ) , area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured/ shade cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for Non skid ceramic coloured joint free tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 13 | Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge. |
| 14 | Taking down chowkhats or frames with shutters of PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and as directed by Engineer-in- charge. |
| 15 | Taking down shutters of any description not exceeding 1.00 sqm each complete all as specified and as directed by Engineer-in- charge. |
| 16 | Supply & Fixing second class hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing Mild steel flat iron 25mm x 6mm as in hold fasts including all necessary cutting etc complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material & Labour for Plain cement concrete type 1: 2: 4, type-B1 (using 20 mm graded stone aggregate as in bed blocks for fixing of hold fasts complete all as specified and directed by Engineer-in-charge. |
| 19 | Supply and Fixing Factory made 35mm thick framed, panelled shutter (two panel) with lock rail made of 2nd class Hard wood and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge. Note: Butt Hinges, Tower bolts, Handles , sliding door bolts and painting shall be measured and paid seperately under appropriate items of schedule 'A' BoQ. |
| 20 | Supply & Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (as approved by Engineer-in-charge) edges of frming plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge. Note:- (i)Wire gauze / glass shall be measured and paid separately under appropriate items of Schedule 'A' BoQ.(ii) Butt Hinges, Tower bolts, Handles , sliding door bolts , ordinary rat tail pattern springs and painting shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.(iii) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. (iv)Primer shall be measured paid separately under appropriate item of BOQ. |
| 21 | Supply & Fixing 30mm thick second class hard wood Glazed and skeleton for window shutters, open rebated and prepared to received glass, gauze etc (without sash bars), edges of framing plain, chamfered, or rounded, fittered with cut mitred beads for securing glass etc complete all as specified and directed by Engineer-in-Charge. Note:- (i)Wire gauze / glass shall be measured and paid separately under appropriate items of Schedule 'A' BoQ.(ii) Butt Hinges, Tower bolts, Handles , sliding door bolts , ordinary rat tail pattern springs and painting shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.(iii) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. (iv)Primer shall be measured paid separately under appropriate item of BOQ. |
| 22 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supply & Fixing 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Supply & Fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge. |
| 25 | Supply & Fixing in replacement Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Supply & Fixing Butt hinges size of 75mm , medium weight cold rolled mild steel (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & Fixing Butt hinges size of 100mm, medium weight cold rolled mild steel (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & Fixing 150mm long mild steel barrel tower bolts, (ISI Marked) stove enameled black, with bright bolts fixed, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & Fixing 100mm long mild steel barrel tower bolts,(ISI Marked) stove enameled black, with bright bolts fixed, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & Fixing 150 mm long Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply & Fixing 100 mm long Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified and as directed by Engineer-in-Charge. |
| 32 | Supply & Fixing 300mm long mild steel sliding door bolts, plate type, (ISI Marked) stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Taking down cement or cement lime plaster from brick wall or concrete surfaces etc including racking out joints, hacking for key & scrubbing down with water etc including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) complete all as specified and as directed by Engineer-in-charge. |
| 34 | Material & labour for Rendering 10mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls, finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour for Rendering 15mm thick in Cement Mortar 1:4 using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces of wall finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-Charge. Note:- Liquid Water proofing compound shall be measured and paid separately under appropriate item of Schedule'A' BoQ. |
| 36 | Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge. |
| 37 | Material & labour for preparation of new plastered surface of walls with and including applying two coats of Oil Emulsion Distemper over with and including one coat of appropriate primer over with and including 3.00mm thick wall care putty (as approved by Engineer-in-charge for smooth & even surface) complete all as specified and directed by Engineer-in-Charge. |
| 38 | Material & labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 39 | Material & Labour complete removal of existing surface and applying two coats of cement base paint over with and including one coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour complete removal of existing treatment and applying two coats of oil emulsion distamper emulsion over with and including 3 mm thick wall care putty over with and including coat of akali resistant primer complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Dismantling wall and ceiling boards (fiber, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Material & Labour 6mm thick plywood, grade BWR, Type BB, fixed in ceiling with screws to timber frame work complete all as specified and directed by Engineer-in-Charge. |
| 43 | Material & Labour 6mm thick plywood, grade BWR, Type BB, fixed in walls with screws to timber frame work complete all as specified and directed by Engineer-in-Charge. |
| 44 | Dismantlingin timber scantlings as in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in sectionn complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply & Fixing 2nd class soft wood (Kail) in scantling clean sawn framed work and fixed complete all as specified and directed by Engineer-in-Charge. |
| 46 | Material & Labour 2nd class soft wood plain fillets square/rectangular or triangular in section of sectional area not exceeding 03 Sqcm splayed chamfered or rounded on one edge or face complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour 2nd class soft wood plain fillets square/rectangular or triangular in section of sectional area exceeding 03 Sqcm but not exceeding 6 Sqcm splayed chamfered or rounded on one edge or face complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material & Labour for preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over with and including one coat of pink primer complete all as specified and as directed by Engineer-in-charge. |
| 49 | Material & Labour for Preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge. |
| 50 | Material & Labour for 75mm thick Cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & Labour for Chequerd Cement Concrete tiles glossy finished of size 30cm x 30cm x 25mm thick with grey cement and pigment , set , jointed and pointed in neat cement slurry @ 3.00Kg /Sqm as in floors , laid over with and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material & Labour Plain Cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) as in coping complete all as specified and directed by Engineer-in-Charge. |
| 53 | Taking down carefully aluminum / copper point wiring on Teak Wood Batten / in conduit / with conduit / in casing and capping(light /Fan / socket or power) complete with and including taking down fittings such as switches, ceiling roses, pendants, Regulators, sockets, light fittings etc complete all as specified and directed by Engineer-in-Charge. Notes:(i) The weight of aluminium scrap, copper scrap and scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item nos.58.00 to 65.00 of BoQ. |
| 54 | Material and Labour in replacement Sub main wiring with two single core of size 2.5 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked , with and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) , drawn in , with and including one single core of size 2.5 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC casing and capping medium grade of suitable size , fittings and earth wire included in sub main wiring. (b) Three single core 2.5 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and Cost of PVC casing and capping medium grade of suitable size and fittings shall be measured as one length. |
| 55 | Material and Labour in replacement Sub main wiring with two single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked , with and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) , drawn in , with and including one single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC casing and capping medium grade of suitable size , fittings and earth wire included in sub main wiring. (b) Three single core 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and Cost of PVC casing and capping medium grade of suitable size and fittings shall be measured as one length. |
| 56 | Material and Labour in replacement Sub main wiring with two single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked , with and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) , drawn in , with and including one single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC casing and capping medium grade of suitable size , fittings and earth wire included in sub main wiring. (b) Three single core 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and Cost of PVC casing and capping medium grade of suitable size and fittings shall be measured as one length. |
| 57 | Supply and Fixing in replacement service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed of nominal cross sectional area 10 Sqmm x 2.00 core complete all as specified and as directed by Engineer-in-charge. |
| 58 | Material and labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , with and including PVC casing and capping of medium grade of suitable size and run on wall / surface with all fittings (ISI Marked) with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. controlled by one switch for one light point/ fan point with and including PVC Gang Box of required size as directed by Engineer- in- Charge including cutting, chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed by Engineer-in-Charge. Notes for serial item nos.58.00 to 61.00 : (i) Switches one way 5 /6 Amp , Switches one way 15 /16 Amp, Socket out lets 5 /6 Amp , Socket out lets 15 1/6 Amp , Switch Socket combination 5 /6 Amp , Switch Socket combination 15 1/6 Amp , shall be measured and paid seperately under respective items of Schedule'A' BoQ.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. |
| 59 | Discription all as per srl item No-58 here in above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed by Engineer-in-charge. |
| 60 | Discription all as per srl item No-58 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed by Engineer-in-charge. |
| 61 | All as per srl item No 58.00 of BoQ here-in-before but 2.50 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.50 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for 3 pin socket outlet 15 Amps with complete all as specified and directed by Engineer-in-Charge. |
| 62 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light / fan point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Notes for serial item nos. 62.00 to 65.00 : (i) Switches one way 5 /6 Amp , Switches one way 15 /16 Amp, Socket out lets 5 /6 Amp , Socket out lets 15 1/6 Amp , Switch Socket combination 5 /6 Amp , Switch Socket combination 15 1/6 Amp shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account. |
| 63 | All as per srl item No-62 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed by Engineer-in-charge. |
| 64 | All as per srl item No-62 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed by Engineer-in-charge. |
| 65 | All as per srl item No-62 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed by Engineer-in-charge. |
| 66 | Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified and directed by Engineer-in-charge. |
| 67 | Supply & fixing for switch socket combination 2 in 1, 3 Pin 5 amps flush type, universal 230 volts complete all as specified and directed by Engineer-in-charge. |
| 68 | Supply & fixing for socket outlet 2 in 1, 3 Pin 5 amps flush type, universal 230 volts complete all as specified and directed by Engineer-in-charge. |
| 69 | Supply & fixing for switch socket combination, 2 in 1, 3 pin 5 and 15 amps flush type, universal 230 volts complete all as specified and directed by Engineer-in-charge. |
| 70 | Supply & fixing for socket outlets 3 pin 15 amps flush type, universal 230 volts complete all as specified and directed by Engineer-in-charge. |
| 71 | Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified and directed by Engineer-in-charge. |
| 72 | Supply & fixing steped type electronic fan regulator flush type . AC, 230 volts, duly ISI marked with and including connector complete all as specified and directed by Engineer-in-charge. |
| 73 | Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge. |
| 74 | Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting complete all as specified and directed by Engineer-in-charge. |
| 75 | Supply and Fixing in replacement Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 76 | Supply & fixing LED lamp 9 W all as specified and directed by Egnr-in-Charge. |
| 77 | Supply & Fixing in replacement LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 78 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 79 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 12 way 230 V AC with 200 Amp rated copper bus bar, Double Door dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 80 | Supply & fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB 10 KA, 'C' Curve complete all as specified and as directed by Engineer-in-charge. Note: The rate of one single pole 20 Amps MCB 10 KA, 'C' Curve is included in this item . contractor his quote rate accordingly. Nothing shall be paid extra on this account. |
| 81 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB Vertical Type TPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 82 | Supply & fixing MCCB 100 Amps 4 pole rupturing capacity 25 kA 4 pole 415 volts fixed typecomplete all as specified and as directed by Engineer-in-charge. |
| 83 | Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 84 | Supply & fixing MCB, DP (Double Pole), AC, 240 volts, 'C' series capacity 40 Amps 10kA and making connections complete all as specified and as directed by Engineer-in-charge. |
| 85 | Supply & fixing MCB, SPN (Double Pole), AC, 240 volts, C series capacity above 40 Amps to 63 Amps 10kA and making connections complete all as specified and as directed by Engineer-in-charge. |
| 86 | Supply & fixing MCB, TPN (four Pole), AC, 415 volts, C series capacity above 40 Amps to 100 Amps 16kA and making connections complete all as specified and as directed by Engineer-in-charge. |
| 87 | Supply & fixing MCB, TP ( Three Pole), AC, 415 volts, C series capacity above 40 Amp to 63 Amps 16kA and making connections complete all as specified and as directed by Engineer-in-charge. |
| 88 | Supply & Fixing in replacement Ceiling fan of 1200mm sweep complete with blades, down rods, including electronic regulator (modular type, 120w, 2 module) and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, complete all as specified and directed by Engineer-in-Charge. Note:- Old Unserviceable ceiling Fan shall be deposited in the store yard of AGE E/M GE 861 EWS |
| 89 | Supply & Fixing exhaust fan made of sturdy engineering plastic complete with louvers shutters, voltage 230V, 50 Hz RPM 1200, copper winding of sweep 250mm including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and as directed by Engineer-in-charge. |
| 90 | Supply and Fixing exhaust fan made of steel body complete with louvers shutters, voltage 230V, 50 Hz RPM 1200, copper winding of sweep 380 mm including necessary work in wall cutting making suitable hole / sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and as directed by Engineer-in-charge. |
| 91 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 92 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 93 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable , Pipes , etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 94 | Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 95 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 96 | Material & Labour for Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified and as directed by Engineer-in-charge.Note : Punned thickness 18 cm will be measured. |
| 97 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. |
| 98 | Material & Labour for Supply, installing, testing and commissioning of CPRI approved LT distribution panel outdoor type of suitable size weather/vermin proof, made out of 3.15mm thick CRCA sheet duly powder coated, mounted on 65x65x6mm (ISA6565) iron angles frame of hight 45 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, including 3 phase and neutral 300 Amps current carrying capacity cupper bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs, including the accessories as below complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and as directed by Engineer-in-charge.(a) MCCB 4 Pole 160 Amps 36 kA - 01 No. (b) MCCB 4 Pole 100A Amps 16 kA - 01 No.(c) MCB SPN 63 Amps 10 kA 'C' Curve -04 Nos.(d) MCB 4 Pole 63 Amps - 04 Nos(e) LED Indicating Lamps R,Y,B -1 Set of three(f) Volt meter0-500 Volts digital Type - 01 No.(g) Ammeter 0-20 Amps digital Type - 01 No. |
| 99 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 32mm x 6mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI strip 32mm x 6mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 100 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 101 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender