| 1 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of Junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.\\"All above operations to be done in order and as directed and specified by the Engineer-in-Charge: (With average thickness of 120 mm and minimum thickness at khurra as 65 mm.) Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to 15: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of Junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.\\"All above operations to be done in order and as directed and specified by the Engineer-in-Charge:(With average thickness of 120 mm and minimum thickness at khurra as 65 mm) |
| 2 | Dismantling brick work or stone work in lime or cement mortar and Including stacking of materials as directed by Engineer-In-Charge within a distance of 60 meters 1200 feet\. Dismantling brick work or stone work in lime or cement mortar and Including stacking of materials as directed by Engineer-In-Charge within a distance of 60 meters |
| 3 | Brick work with common burnt clay (non modular) bricks of class -150 in super structure Cement mortar 1:4 (1 cement: 4 coarse sand) Brick work with common burnt clay (non modular) bricks of class -150 in super structure above plinth level up to floor V level in all shapes and sizes. Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 4 | 12mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. |
| 5 | Concrete/R.C.C. Work-RCC work with cement approved coarse sand and 20mm approved stone ballast in proportion for raft foundation with 1:1.5:3 (1 cemnt 1.5 C. sand 20 mm size stone ballast) Reinforced cement concrete work In beams, suspended floors, roofs having slope up to 15• landlngs, balconies, shelves, chaDas, lintels, bands, plaln window sllls, staircases and splral stair cases above pllnth level up to floor five level, excluding the cost of centering, shuttering, finishing andreinforcement. |
| 6 | M.S. or iron in plain work such as hevey size as fabrication of M.S. M.S. or iron in plain work such as hevey size as fabrication of M.S. |
| 7 | P/F stainless steel kitchen sink kitchen sink with drain board 510x1040mm bowl depth 250mm etc all comp p/f stainless steel kitchen sink kitchen sink with drain board 510x1040mm bowl depth 250mm etc all comp |
| 8 | Supply and fixing of anodized aluminium partition having 2mm thick aluminium. Section, partly glazed and partly 12mm thick laminated board. Aluminium board size 83.50x44.65mm as vertical member and 11.40x44.45 as bottom and horizontal member with all fitting, glass panes of 4mm thick handle and locks complete. |
| 9 | 15 mm nominal outer dla Pipes Providing and flxlng Chlorlnated Polyvinyl Chloride (CPVC) pipes, having thermal stablllty for hot & cold water supply, Including all CPVC plain & brass threaded fittings, Including fixing the pipe with clamps at 1.00 m spacing. This Includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints complete as per direction of Engineer In Charge. Internal work • Exposed on wall |
| 10 | 15 mm nominal bore Providing and fixing C.P. brass bib cock of pproved quality conforming to IS:8931 |
| 11 | Providing and fixing vitreous china dual purpose closet suitable for use as Squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of Standard make and mosquito proof coupling of approved municipal design Providing and fixing vitreous china dual purpose closet suitable for use as Squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of Standard make and mosquito proof coupling of approved municipal design |
| 12 | White Vitreous china Orlssa pattern W.C. pan of size 580x440 mm with Integral Itvoe foot rests Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, Including cutting and making good the walls and floors wherever required |
| 13 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 14 | Scrapping old white or colour wash including disposal of refuse as directed by Engineer-In-charge within a distance of 60 meters (200 feet) Scrapping old white or colour wash including disposal of refuse as directed by Engineer-In-charge within a distance of 60 meters (200 feet) |
| 15 | New Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work |
| 16 | New Finishing walls with exterior emulsion paint (Apex) Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over @ 1.25 Ltr/l0sqm including one coat of primer applld @ 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required fororooer comoletlon of work.for two coat. |
| 17 | Retaining walls, return walls, walls (any thickness) Including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. Centering and shuttering including strutting, propping etc. and removal of form work for (Upto 5th Floor) |
| 18 | Add 18 % G.S.T. Please Enable Macros to View BoQ information |