| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge., All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 3 | Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the work and including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. (SI No. 504) (Sanction Rate) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting and propping and removal of items for: Foundations, footings, base of columns, etc DSR 2023/5.9.1 |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for :, Suspended floors, roofs, landings, balconies and access platform |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :, 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 10 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:, Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | 15 mm cement plaster on rough side of single or half brick wall of mix :, 1:6 (1 cement: 6 coarse sand) |
| 14 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 15 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customized design as per direction of Engineer in charge. The glass mosaic tiles shall be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operations, material and required pattern approved by Engineer-in-charge. |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 17 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:, New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 18 | Supplying, fabricating, transporting, hoisting and fixing in position of Sculputure as per approval, free from cracks, lines stains and even in shade for each element. The work shall be carried out as per approved drawings processes including carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding etc. The sculpture to be securely fixed in line, level and plumb over a suitable platform in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make to withstand all weather conditions as required to the satisfaction of Engineer-in-Charge |
| 19 | Designing, supplying, Installation & Testing of Foaming jet Fountain of High quality. |
| 20 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN PWD 807 f |
| 21 | Shrub Uplighter: SITC of uplighter with Input power : 6W spike mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene black. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 101mm length x 64mm width x 330mm height. All tolerance should be ±15%. Inhouse NABL aeredited Lab Certificate, CE & BIS Certificates to be enclosed with the Tender document. The fixtures proposed must have passed LM 79 & LM-80, Reports from inhouse NABL laboratory to be submitted post the issuance of LOA to the successful bidder on and before the supply of material. All complete including consumables required for installation as per approved sample and directed by Architect/ Engineer-in-charge. Make: K-Lite Model- KL-4265/ Ligman/ Wipro |
| 22 | Entrance (Office Ticket Counter & Food Stall): SITC of Static White 3000K 18W adjustable In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting with Ø173 x 220mm,the Ø173 front ring should be made up of stainless steel 316 grade front ring with silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 1200-1500 lm for 3000K BEAM -40°. The ingress protection is IP67 and impact resistance of IK09 . The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C.Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. Inhouse NABL aeredited Lab Certificate, CE & BIS Certificates to be enclosed with the Tender document. The fixtures proposed must have passed LM 79 & LM-80, Reports from inhouse NABL laboratory to be submitted post the issuance of LOA to the successful bidder on and before the supply of material. All complete including consumables required for installation as per approved sample and directed by Architect/ Engineer-in-charge. Make: K-Lite/ Wipro / ligman |
| 23 | \\"Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. S.I.No-726 B/18.\\" |
| 24 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 25 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required., 2 X 6 sq. mm (19mm) |
| 26 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required., 4 X 10 sq. mm (25mm) |
| 27 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required., 3-1/2 X 25 sq. mm (28mm) |
| 28 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 6 sq. mm 2 core |
| 29 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 10 sq. mm 4 core |
| 30 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 25 sq. mm 3-1/2 core |
| 31 | Supply and Installation of Underwater surface mounted 18W LED fountain light. CCT 3000K, Beam angle 20°. Luminaire complete housing made of marine grade 316 stainless steel. Step tempered glass of 8mm thickness. Suitable for water jet pipe of G(PF)3/4 taper. Hard wired for single colour 2 x 1.0mm2 3metres water resistant cable. A water arrestor in luminaire serves to prevent water intrusion into the fixture. Protection class IP68. Mechanical resistance IK09. Available colour temperature 3000K, Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 54,000 operating hours. Low Voltage non integral power supply at 12Vdc assures safety. Recommended installation depth upto 1meter below the water surface. |
| 32 | SITC of 24W Linear Wall Washer LED 3000K, 4000K, 6000K 24Vdc CRI >80 MacAdam step 3 Dimension : 1000 x 35 x 78 mm Beam angle : 30° / 15°x60°, Electronic romote driver ON/OFF, Surface Mounted luminaire. IP rating IP65, Extruded aluminium alloy housing (grade 6063). Toughened clear glass diffuser. SS fasteners. Mechanical resistance IK06. Aluminium mounting bracket for surface mounting on ground. Toughened Clear glass diffuser and optical to reduce glare controlled. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C with delivered lumen of 2400lm. |
| 33 | Supply and Installation of LED backlit illuminated lettering/signage for wall-mounted architectural display, comprising high-efficiency SMD LEDs with minimum efficacy of 120 lm/W, housed in powder-coated aluminium/acrylic enclosure with opal diffuser for uniform illumination, complete with IP65 protection, UV-resistant weatherproof construction, inbuilt electronic driver operating on 220–240V AC supply, color temperature 3000K/4000K as approved by Engineer-in-Charge, minimum CRI 80, surge protection up to 4kV, average LED life not less than 50,000 burning hours, size of alphabet should be atleast 500mm. |
| 34 | Supplying, installation Testing and Commissioningof 2 x 2.5 sq mm Copper Speaker Cable in PVCConduit of specified make, complete as per the attached approved make list and with proper connections etc complete in all respect as directed by Engineer-in-charge.. |
| 35 | Supplying, installation, testing and commissioning of IP-65,Outdoor type external feeder panel suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, suitable RCC pedestal, including earthing connections as per specification and schematic diagram as required. INCOMER:- 1 Nos. 100 A FP MCCB (36KA) BUS BARS:- 200 Amps. TP&N Copper bus bars (50 KA) OUT GOINGS:- 8 Nos. 40 A FP MCB (50KA) 6 Nos. 40 A TP Power Contactor 6 Nos Astonomical Digital Timer Switch |
| 36 | Supply and installation of DC power driver for the above Lights, Power: 150 W, Input: AC 110-240V AC, 50Hz, Output: DC 12/24V, Protection rating IP67, surge protection 4KV all complete including consumables required for installation as per approved sample and directions of Architect/ Engineer-in-Charge. |
| 37 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :, White sand stone - Exposed face machine cut and table rubbed with rough backing., 40 mm thick |
| 38 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in wallswherever required. |
| 39 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 40 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level:, In two coats |
| 41 | Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :, White sand stone |
| 42 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR No. 16.69 |
| 43 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. |
| 44 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 45 | Fine dressing of the ground. |
| 46 | Mixing earth and sludge or manure in the required proportion specified or directed by the officer-in-charge. |
| 47 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately), Holes 90 cm dia, and 90 cm deep |
| 48 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water) Hedge. DSR Horticulture 2020/2.57.3 |
| 49 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 50 | Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). |
| 51 | Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately)., With grass Turf |
| 52 | Providing and stacking of Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 53 | Providing and stacking of Thevetia nerifolia of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 54 | Providing and stacking of Plumeria acutifolia of height 150-165 cm. with 3- 4 branches in big size HDPE bag as per direction of the officer-in-charge. |
| 55 | Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. |
| 56 | Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge. |
| 57 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 58 | Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 nos. 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/ PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, complete in all respect. |
| 59 | 40 mm thick fine dressed stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone., Red sand stone |
| 60 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage., For horizontal surface one coat @1.10 kg per sqm. |
| 61 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage., For vertical surface two coats @ 0.70 kg per sqm |
| 62 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :, Screened through sieve of I.S. designation 4.75 mm Please Enable Macros to View BoQ information |