Water Resources and Irrigation Government Departments Closing in 6 days TDR #56197720

Tender for Tender for Renovation Of Navabganj Inspection Bhavan And Staff Quarter At The Entrance Of Sharda Sagar Khand Pilibhit And Construction Of Pre Cast Boundary Wall To Protect The Rajkiye Land Situated At The Sarora And Amkhidiya Kothi.

Issued by Government Departments · Pilibhit, Uttar Pradesh
Tender Value
78.12 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
6 days left
EMD
1.57 Lakhs
Bank guarantee accepted
Document Fee
2715
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pilibhit → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of Navabganj Inspection Bhavan And Staff Quarter At The Entrance Of Sharda Sagar Khand Pilibhit And Construction Of Pre Cast Boundary Wall To Protect The Rajkiye Land Situated At The Sarora And Amkhidiya Kothi.

BOQ

Name of Work:- kkjnk lkxj [k.M] ihyhHkhr ds vUrxZr uokcxat fujh{k.k Hkou ,oa LVkQ DokVZj ds uohuhdj.k rFkk ljkSjk o vef[kfM+;k dksBh ij fLFkr jktdh; Hkwfe dh lqj{kk gsrq izhdkLV ckm.Mªhoky dk dk;ZA
Sl. No. Item Description
1Dismentling existing plaster including disposal of refuse as directed by the Engineer-in-charge with in distance of 60 Meters.
2Racking our joints of Brick work in cement or lime, mortar to a depth of 1 cm (3/8”) including disposal of refuse as directed by the Engineer-in-charge with in 60 metre.
3Scraping Old white wash or colour wash including disposal of refuse as directed by the Engineer-in-charge with in 60 mts
4Dismentling Cement concrete or brick or granolithic floor including base concrete and including stacking of dismantled material as directed by Engineer Incharge with in 60 Meters distance.
5Dismentling door and window chaukhat with hold fast including stacking of dismantled material as directed by Engineer Incharge with in distance of 60 Meters.
6Earth work in foundation in dry ordinary soil including lift up to 1.50 m and lead up to 30 m and including back filling, watering and ramming of excavated earth into the trenches or into the space between the structure and the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the Engineer-in-charge.
7Laying C.C. 1:3:6 Mix (M-10) cement, coarse sand & 20 mm down graded stone grit including cost of all material, labour and T&P etc. complete but excludiing cost of shuttering.
8Brick work (M-150) in 1:6 cement and coarse sand mortar in foundation, Plinth & Wall including supply of all material, labour and T&P etc. required for proper completion of work.
9Centering & Shuttering for R.C.C. Work in foundation, columns, beams, lintels, sunshades, roof slabs with MS Plates/Plywood panels of required shapes & sizes including all material & labour required to complete the work at ground floor.
10R.C.C. work with approved cement, coarse sand and 20 mm gauge stone aggregate in the proportion of 1:1.5:3 ( M-20) in the slab etc, excluding supply of reinforcement and its bending and cutting also excluding necessary centering and shuttering etc. but including supply of all material and T&P etc. required for proper completion of work in Columns, Beams, Roof Slab, Lintels, Sunshades etc. or as directed by the Engineer-in-charge.
11Mlid steel (Tor/TMT) in reinforced concrete work wrought to required shape as necessary including bending as per requirement and direction of Engineer-in-charge for proper completion of the work and including supply of steel, its wastage, labour and T&P etc. complete. (Bend, hooks and authorised overlapping in inforcement shall be measured.
1212 mm thick plaster with cement mortar in proportion of 1:6 cement and sand over brick work, minimum thickness not to be less than 1 cm including supply of material, labour and T&P etc. required for proper completion of work or as directed by the Engineer-in-charge..
13Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered surface to prepare the surface even and smooth complete.or as directed by the Engineer-in-charge..
14Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 13.112.1 Old work (Two or more coats applied @ 1.43 Itr/ 10 sqm) over existing cement paint surface or as directed by the Engineer-in-charge.
15Distempering with 1st quality acrylic distemper (two or more coat) (ready mixed) having VOC contect less than 50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour or as directed by the Engineer-in-charge..
16Suppling & fixing angle choukhat with ISA 40X40X6 with fabrication and all complete material or as directed by the Engineer-in-charge.
17Suppling & fixing angle iron window frame making T with ISA 40X25X4 , and 10 mm sq bar grill, with fabrication and all complet material or as directed by the Engineer-in-charge.
18Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
19Suppliying and fixing flush doors 35 mm thick commercial quality conforming to I S 2202 part I(1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handle spring fitting with necessary screws to be supplied departmentally. required for proper completion of the work as per direction of Engineer-in-charge
20Providing & Fixing 6 mm (1/4'') china white glazed in flooring or skirting dado & walls confirming of any size with 1:3 cement and approved coarse sand mortar finished white cement slurry jointing and polishing complete including supply of all material, labour and T&P etc. required for proper completion of work or as per direction of Engineer-in-charge
21Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
22Treatment of existing masonary using chemical emulsion @one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole and With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
23Plain cement concrete Flooring laying 4 cm thick 1:2:4 Mix (M-15) cement, coarse sand and 20mm down graded stone grit laid in panel and finished with 3mm neat cement floating coat and giving them a uniform finish including cost of all material labour and T&P etc.complete or as directed by engineer in charge.
24Providing and laying of factory made 80mm thick interlocking cement concrete tile including 25mm compacted bed of fine sand compacting and proper embedding / laying of interlocking tile leveling and dressing of surface to required level and slope, filling joints with fine sand including the cost of material, labour T & P etc. required for proper completion of work as directed by engineer in charge.
25Providing & fixing fly proof wire galvanized M.S wire gauge to window and clerestory window using galvanized M.S wire gauge with average width of aperture1.4 mm in bot directions with wire of dia. 0.63 mm with 2nd class teak wood bidding 62x19 mm or as directed by engineer in charge.
26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two more coat or as directed by engineer in charge.
27Supplying and fixing steel tabular pole 7 Meter long designated 410 SP 3 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect with LED street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt Confirming to IP 66 protection
28Supplying and laying of aluminium conductor PVC insulated armoured served shethed cables 1100 volts garde at a depth of 750 mm below ground level over a cushion of 75 mm tick sand all around and protected with brunt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect. The armouring of the cable shal be properly connected with the earth conductor by clamps etc.
29Supply & Fixing SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEMSupplying, installation, testing and commissioning of grid interactive roof top solar photo voltaic power generation system including space fram 5KW Solar System including all cost of Battery, Solar pannel and Solar Inverter Material, Labour, T&P Etc.
30Supply & fixing of reflective sign board (Single side) of size 1.50x1.20 m retro reflective sheeting of HIP grade type-IV, the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick, ACP sheet of standard make as per MORTH specificaton. The Board shall be fixed using 2 man post 45x45x60 cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder property including bufting so an to give uniform shining at weded joints, The retro reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67:2012 & proof of the same in form of government report shall be uploaded while quoting tender.
31Supply and installation of concrete Pannel Boundary wall upto 2.10 M height from G.L. ( Prestressed concrete of grade M-25 with 4 Nos of 4 mm STS wire) slab of size 2100mm x 300x 50mm with fixing of same at proper position between two pillers/column with same grade of concrete ( pre stressed with 7 Nos of STS wire) of size 2740mm x 150mmx 150mm with provision of edge grove (50mm x 50mm ) two opposite phase for holding precast slab/Pannel including footing 450mm x450mm x600mm with grade M-20 and base concrete 450mm x450mm x200mm & 550mm x550mm x100mm grade M-10 also including all material, labour, T&P etc, carriage at site complete with contractor profit.
32Providing and fixing 1 mm thick M.S sheet garrage door with frame of 40x40x6 mm(11/2 x 11/2 x 1/4'') angle iron, 3.15 mm 1/8'' thick M.S gusset plates at the junctions and corners, including supply and fixing of necessary fittings. Lock rail of 37.5 cm length of oxidised iron and incuding pintels, hooks at the top and applying a priming coat of red lead paint on all sides complete.
33Supply and fixing of 10 cm dia PVC pipe (Kisan, supreme or equivalant) 6 kg/sqcm pressure complete with PVC Bends, Elbow, Tee, Union, Gratings etc all fittings and including jointing of pipes, supply of necessary M.S damps 2.5cm x3mm fixed to wall's, 15 cm long, 6mm dia nails all materials, labour and T & P etc Required for completion of the work and also incuding repair of plaster, pointing etc, If damaged during fixing of the pipe as per direction of Engineer-In-Charge.
34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
35Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes
36Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
37Providing and fixing gun metal gate valve with C.l. wheel of approved quality (screwed end) :25 mm nominal bore
38Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.
39Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
40Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
41Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
42Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
43Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 250 mm
44Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia or as required.
45Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia or as required.
46Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to 1S:8931. 15 mm nominal bore or as required.
47Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore or as required.
48Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter or as required.
49Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
50Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete or as required.
51Providing and fixing toilet paper holder : C.P. brass or as required.
52Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms or as required.
53Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms or as required.
54Boring/drilling bore well of 300 mm dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil or as required.
55Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size or as required.
56Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia or as required.
57Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C or as required.
58Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. For SPN industrial type, socket or as required.
59Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire . For 15 amp socket or as required.
60Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
61Supplying and fixing 3 pin 5/6 A modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
62Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door or as required.
63Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole or as required.
64Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp or as required.
65Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
66Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
67Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
68Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56197720
AUTHORITY Government Departments
TENDER VALUE 78.12 Lakhs
LAST DATE 08-07-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Renovation Of Navabganj Inspection Bhavan And Staff Quarter At The Entrance Of Sharda Sagar Khand Pilibhit And Construction Of Pre Cast Boundary Wall To Protect The Rajkiye Land Situated At The Sarora And Amkhidiya Kothi.
Basic Detail
Tender No 01/SE/2026-27
Bidding Type Tender
Location
City Pilibhit
State Uttar Pradesh
Key Dates
Publish Date 29 Jun 2026
Submission Date 08 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 78.12 Lakhs
Tender Fee 2715
EMD 1.57 Lakhs
Exemption Available
Document List
48db21f4-1e68-4c31-9b3b-1585223eafcc.html
BOQ_2182673.xls
LOT09.pdf
Tendernotice_1 (25).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

48db21f4-1e68-4c31-9b3b-1585223eafcc.html

xls

BOQ_2182673.xls

pdf

LOT09.pdf

pdf

Tendernotice_1 (25).pdf

TenderDetail
Loading tenders