| 1 | Item Code [11.2-2025]:Item Type [Electrical] ::Sub Item Code [11.2-2025 + 11.2.12/11.2.12.2]: Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. 120.0 Sq. mm/3.5 core |
| 2 | Item Code [12.13-2025]:Item Type [Electrical] ::Sub Item Code [12.13-2025 + 12.13.6]: P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). 120 mm |
| 3 | Item Code [13.1-2025]:Item Type [Electrical] ::Sub Item Code [13.1-2025 + 13.1.4]: Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC pipe / Hume Pipe/ Stoneware Pipe/ PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. 3 core 185.0 Sq.mm |
| 4 | Item Code [13.3-2025]:Item Type [Electrical] :: Excavation of trench of size 120 cm (Depth) x 35 cm(Width) for Laying of suitable no. of HT cable( Inter spacing between cables should not be less than 2 D) in ground with following procedure:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 5 | Item Code [13.7-2025]:Item Type [Electrical] ::Sub Item Code [13.7-2025 + 13.7.2/13.7.2.3]: Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. 11 KV End Termination Kit Outdoor type/3 core 120/150/185 Sq.mm |
| 6 | Item Code [14.8-2025]:Item Type [Electrical] ::Sub Item Code [14.8-2025 + 14.8.9]: Supply & Laying following size B class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra) 100 mm dia. |
| 7 | Item Code [19.1-2025]:Item Type [Electrical] ::Sub Item Code [19.1-2025 + 19.1.2]: Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. 9.0 Mtr long PCC pole of 200 Kg Working Load |
| 8 | Item Code [19.11-2025]:Item Type [Electrical] ::Supply and fixing of MS. Channel Bracket 100 mm x 50 mm with clamp as per Discom Specifications including Nut, Bolt with two coats of Red oxide and two coats of Aluminium paint etc. as required. Sub Item Code [19.11-2025 + 19.11.2]: Supply and fixing of MS. Channel Bracket 100 mm x 50 mm with clamp as per Discom Specifications including Nut, Bolt with two coats of Red oxide and two coats of Aluminium paint etc. as required. 1.4 Mtr. Long |
| 9 | Item Code [19.13-2025]:Item Type [Electrical] :: Supply and fixing of 11 kV pin insulator confirming to IS:731:1971 with latest amendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required. |
| 10 | Item Code [19.14-2025]:Item Type [Electrical] ::Sub Item Code [19.14-2025 + 19.14.1]: Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. B & S type hardware 45 KN |
| 11 | Item Code [19.14-2025]:Item Type [Electrical] ::Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required.Sub Item Code [19.14-2025 + 19.14.3]: Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. B & S disc insulator 45 KN |
| 12 | Item Code [19.16-2025]:Item Type [Electrical] :: Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respect Including chemical composition (Heavily coated Hard quality) of dia 7/3.15 mm(7/10 SWG) and as per latest Discom specs. etc. as required. |
| 13 | Item Code [19.17-2025]:Item Type [Electrical] ::Supply and fixing of 11 / 33. KV Stay insulator as per IS:5300/1969 and as per Discoms standard specifications etc. as required. Sub Item Code [19.17-2025 + 19.17.1]: Supply and fixing of 11 / 33. KV Stay insulator as per IS:5300/1969 and as per Discoms standard specifications etc. as required. 110 x 75 x 22mm 11 KV Stay Insulator |
| 14 | Item Code [19.18-2025]:Item Type [Electrical] ::Sub Item Code [19.18-2025 + 19.18.2]: Supply and fixing of LT Distribution Kiosk confirming to IS:13947/1993/ IEC 60947 Pt.3 amended up-to-date and as per DISCOM specifications made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including Incoming Switch Disconnector Fuse unit, Aluminium Busbar with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS Channel frame of 75 mm x 40 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for required no. of outgoing. 400 Amp. LT Distribution Kiosk for 250/315 KVA Transformer |
| 15 | Item Code [19.2-2025]:Item Type [Electrical] ::Sub Item Code [19.2-2025 + 19.2.1]: Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as required. Stay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x 380 x 4.0 mm |
| 16 | Item Code [19.20-2025]:Item Type [Electrical] :: Supply and fixing of 100 Amp, 11kV Horn gap fuse set IS 9385 on existing DP structure with 6 nos 24kV/22kV post insulator (IS:5350 part III), hot dipped hard ware,fuse wire of required size etc. complete in all respect as per Discom specification etc. as required. |
| 17 | Item Code [19.21-2025]:Item Type [Electrical] :: Supply and fixing of 11kV, 400 Amp 3 pole, central pot rotating double break type isolator (IS:9921 part I toV) without earth blade operating mechanism with GI spring loaded reverse loop type fixed contact, solid hard drawn electolytic copper tubular moving contact with silver/ nickel plated at end points, 9 nos post insulator of 12 kV (IS:2554 & IS 5350 part III), hot dipped galvanising hard ware, nut, bolts etc complete in all respect as per Discom specification etc. as required. |
| 18 | Item Code [19.25-2025]:Item Type [Electrical] :: Providing and fixing of single pole mounted substation structure set for isolator / single phase transformer as per DISCOM specification complete in all respect with nuts and bolts as required MS flat 50 x 6mm, MS angle 65 x 65 x6mm, MS channel 100 x 50 x 6mm. ( Excluding cost of pole ). Etc. as required. |
| 19 | Item Code [19.28-2025]:Item Type [Electrical] :: Supply & Erection of M S lattice structure of height 12.8 mtr as per DISCOMs approved design & details in alignment, including painting of tower of approved make two coat of red oxide paint and one coat of aluminium paint before installation and one coat of Aluminium paint after erection work completed as per technical specifications & drawing of DISCOM. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra). |
| 20 | Item Code [19.3-2025]:Item Type [Electrical] ::Sub Item Code [19.3-2025 + 19.3.2]: Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. LT cross arm 1200 mm long with clamp |
| 21 | Item Code [19.32-2025]:Item Type [Electrical] :: Supply of Fabricated 33 KV of V type cross arms made of MS angle (75x75x6 mm) with clamp etc as per Discom specifications on the existing poles complete including all necessary nut and bolt etc with clamps including two coats of Red oxide and two coats of Aluminium paint etc. as required. |
| 22 | Item Code [19.4-2025]:Item Type [Electrical] ::Sub Item Code [19.4-2025 + 19.4.1]: Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. 100 mm x 70 mm |
| 23 | Item Code [19.42-2025]:Item Type [Electrical] :: Labour charges for Dismantling the structure with pole mounted transformer of different capacity along with distribution boards and re- erecting the transformer on newly erected structure along with distribution boards and including testing and commissioning (as well as cabling connection complete as required) |
| 24 | Item Code [19.43-2025]:Item Type [Electrical] :: Labour charges for dismantling of existing PCC/MS electrical Pole including MS channel, V cross arm, 11KV insulator, LT insulator, guard wires, stay wires, one span of ACSR conductors and other electric items, coming along and in the alignment of the road, then removal and re-rolling of the PCC /MS Pole as well as other materials and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge, clean the site good as per the requirement and dismantle material receipt duly signed by DISCOM Engineer submit the receipt to EIC as required. |
| 25 | Item Code [19.44-2025]:Item Type [Electrical] :: Labour charges for dismantling of existing Lattice tower including MS channel, V cross arm, 11KV/33 KV insulator, guard wires, stud/stay wire, one span of ACSR conductor and other electric items coming along and in the alignment of the road, then removal and re-rolling of Lattice tower as well as other materials and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from DISCOM/ concering authority complete as required. |
| 26 | Item Code [19.46-2025]:Item Type [Electrical] :: Labour charges for dismantling of service line connection (weather proof cable/armoured cable) for single phase /three phase supply of industrial/domestic connections from existing PCC/MS pole and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and provide temporary supply to domestic/industrial connections to the consumer where supply is disconnected and clean the site good as per the requirement and direction of Engineer Incharge complete as required. |
| 27 | Item Code [19.47-2025]:Item Type [Electrical] :: Labour charges for Trimming of tree branches/plants and prepairing route approaches for electric proposed line complete with prior permission of local authority in writing , taking proper shutdown from discom office and inform to DISCOM after complete the work. |
| 28 | Item Code [19.5-2025]:Item Type [Electrical] :: Sub Item Code [19.5-2025 + 19.5.1]: Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. 75mm x 90mm |
| 29 | Item Code [19.6-2025]:Item Type [Electrical] ::Sub Item Code [19.6-2025 + 19.6.3]: Supplying and drawing Aluminium conductor steel reinforced (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. 50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit) for LT |
| 30 | Item Code [19.6-2025]:Item Type [Electrical] ::Sub Item Code [19.6-2025 + 19.6.5]: Supplying and drawing Aluminium conductor steel reinforced (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. 100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog) |
| 31 | Item Code [19.9-2025]:Item Type [Electrical] ::Sub Item Code [19.9-2025 + 19.9.1/19.9.1.1]: Supply and fixing of top hamper on the existing pole as per latest Discom specifications complete including nut bolts with two coats of Red oxide and two coats of Aluminium paint etc as required. vertical type/11 kV (.7m long) (65 x 65 x6mm angle) |
| 32 | Item Code [23.32-2025]:Item Type [Electrical] ::Sub Item Code [23.32-2025 + 23.32.2]: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 33 | Item Code [23.6-2025]:Item Type [Electrical] ::Sub Item Code [23.6-2025 + 23.6.1]: SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated stainless steel Outdoor enclosure of thickness of 2 mm and tank of stainless steel Outdoor enclosure of thickness 3mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for both Cable chamber and gas tank as per IEC 62271-200 and LBS to be rated for class E3 as per IEC 62271 - 103. Vacuum Interrupter should be same as used during type test of RMU. Each feeder of RMU should have voltage presence indicator. and VCB feeder should consist of 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder, 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB. Load break switch feeder shall have Fault Passage indicator, Right angle boots for all the feeder Modules, Remote trip, Emergency Stop, Cable cover interlocking, Transformer protection tapo card etc. All the type test certificates as per IEC and CEA from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) Non Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch Please Enable Macros to View BoQ information |