| 1 | M&L for 15 mm thick rendering in water resistant readymix cement mortar on fair faces and other than fair faces of brick work or concrete surfaces of walls, finished even and fair complete all as specified and as directed.Note :- Contractor shall be bounded to carryout repair / maint upto G+1 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories. |
| 2 | M&L rendeing 5 mm thick with ready mix plaster on ceiling surfaces finished even and smooth without using extra cement including taking down existing cement plaster and scaffolding arrangement to carry out the work complete all as specified and as directed. |
| 3 | M &L for providing and applying a bond coat of Latex:Water:cement - 1:4:6 consumption @100gm/sqm on the brick wall surface by brush as per manufacturer's recommendations including curing complete all as specified and as directed. |
| 4 | Expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes : Drilling holes 10mm diameter in masonary structure along the side of the joint as per manufacturer's instructions so as to cross the brick/ block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge.Cleaning of holes : Clean the holes by air blower prior to fixing nozzles. Install latex polymer packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using sealent.Cutting of Packers : Cut the packers after completion of grouting without damaging structural elements. |
| 5 | Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump injcection of polymer resin compound at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or polymer compound appears at the packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line complete all as specified and as directed. |
| 6 | M&L for preparation of newly plastered surfaces of wall/ceiling sufraces and applying two coats of super quality weather proof exterior emulsion paint over a coat of primer and 1mm thick waterproof cement based putty using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and as directed. |
| 7 | M&L for preparation of newly plastered surfaces of wall/ceiling sufraces and applying two coats of oil bound distemper on wall/ceiling surfaces over a coat of primer and 1mm thick cement based putty using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and as directed. |
| 8 | M&L for complete removal of existing treatment under (OBD/Oil paint/ white wash etc) by scrapping with mechanical wall sander on wall/ceiling (having mechanical vacuum mechanism) having RPM not less than1500, sending pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint , removal of nails etc and filling cracks/ holes and windows /doors jams by putty & repairs in good shape by skilled labour complete all as specified and directed. |
| 9 | M&L for waterproof cement based putty @ 1Kg (undiluted) per square meter of average thickness 1-2 mm over a coat of primer over wall /ceiling surcafes to make the surface free from dust etc, by skilled labor as per following steps :-Step 1 :- Mix the putty powder by adding water as per manufacturer instructions and mix it with wall mixture with the mixing capacity of minimum 2.5 kg putty per minute Step 2 :- Applying the first coat of prepared mixture over a coat of primer.with the help of fully automatic airless spray machine of putty application having flow speed of maximum 6 liters per minute with a maximum pressure of 3300 PSI. Step 3 :- Allow 6-8 Hrs time to dry the putty surface. |
| 10 | M&L for applying two coats of oil bound distemper on wall/ceiling surfaces using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and as directed. |
| 11 | M&L for applying two coats of super quality weather proof exterior emulsion paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and as directed. |
| 12 | M&L for preparation of old painted surface of wall with steel wire brushes/mechanical scrapping machine and applying one coat of oil bound distemper on wall/ceiling surfaces using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and directed. |
| 13 | M&L for preparation of old painted surface of wall with steel wire brushes/mechanical scrapping machine and applying one coat of super quality weather proof exterior emulsion paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paint should be able to spray in hard to reach areas and penetration of paint on the surface complete all as specified and as directed. |
| 14 | M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cms width or girth and apply one coat of synthetic enamel paint, complete all as specified and directed by engineer-in-charge. |
| 15 | M&L for preparation of old steel surfaces of any description not otherwise described over 10 cms width or girth and apply one coat of synthetic enamel paint, complete all as specified and directed by engineer-in-charge. Notes:- Applicable to srl item No 6.00 to 15.00 (a) The smart periodical work under this contract shall be executed by manufacturers authorized applicator after approval of name of manufacturar's by GE. (b) The contractor shall produce the name brandof material and it manufacurar's within 10 days from the date of award of tender. After approval of paint manufracturer and product brand, the contractor shall produce a \\"Memorandum of Understanding\\" (MoU) between contractor, applicator and the manufacturer within 28 days from the award of of tender date or before commencement date of work. wherein the manufacturer shall own the responsibility of use premium quality products in adequate quality and workmanship. The Contractor shall also produce purchase Vouchers/Invoice for all product/materialutilised in work for their full quantity and Engineer-in-charge shall ensure to kept in record duly defaced& verified. (c) Sanding of surfaces shall be carried out by mechanical sander having speed 1500–2700 RPM with internal dust extraction system to maintain clean environment and certified by paint manufacturer. |
| 16 | (d) Electrical fittings such as tube lights, bed lights, switch boards etc. shall be carefully taken down before commencement of painting work and refixed after completion of painting work.(e) Furnitures in the quarters shall be shifted and stored in one room before commencement of painting work and rearranged to original position after completion of work.(f) Entire quarters including flooring, doors and windows shall be cleaned by the contractor after completion of painting work.(g) The rates quoted by the tenderer shall be deemed to include all the above provisions and nothing extra shall be paid on this account. |
| 17 | S&F in repair stainless steel wire cloth, 0.63mm nominal dia or wire and sqm average width or aperature 1.40mm, fixed with tinned tacks or galvanised wire staples to doors/steel windows, complete all as specified and as directed. |
| 18 | S&F sheet glass 4 mm thick , ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 sqm in each pane complete all as specified including hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads metal frame complete all as specified and as directed. |
| 19 | S & F false ceiling at all hights with GRG (Glass Fifre Reinforced Gypsum, with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling) False Ceiling Tiles of size 595x595mm Make : Diamond ceiling with Trade Mark Brand TM manufactured by Diamond International Inex Pvt Ltd of approved texture, design and patterns having Moisture contant less then 2% Humidity resistance of 99%, NRC .050-0.85 as per IS8225:1987,Non combustible as per BS 476(Part -4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal lavel suspended on inter- locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @120grams per sqm including both sides ) comprising of main - T runners of size 15x32mm of length 3000 mm ,Cross - T of size 15x32 mm of length 1200 mm and secondary intermediate Cross T of size 15x32mm of length 600mm of form Grid module of size 600x600mm, suspended from ceiling using galavanised mild steel items (galvanizing @80 grams per sqm) i.e.50mm long, 8mm outer diameter M- 6 dash Fasteners,6mm dia fully threaded hanger rod upto 1000mm length and L -Shape lavel adjuster of size 85x25x2mm Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rrawl plugs at 450mm center to center and 40mm long dry wall SS screws including dismantling of existing false ceiling board any type complete all as specified and as directed. |
| 20 | S&F in repair PVC hollow false ceiling interlocking type 5-7mm thick plain/ coloured, fitted with MS hollow grid (light weight) section 25mmx25mmx1mm thick including fillets on joints, with hanging arrangements and including maintain levels with adjustable clips, complete all as specified complete all as specified and as directed. Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing. |
| 21 | S&F hollow PVC Wall panelling made from wood grain printed PVC sheet, panels interloked with each other and fixed with wall including dismantling of existing wall panelling/boarding with fillets any type any description complete all as specified and as directed. |
| 22 | S&F in repair Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and including fixing of 5mm thick PVC sheet fillets of width 35mm (spacing @300mm c/c vertically and 600mm c/c horizontally upto any heigt) for fixing sheet on it including dismantling of existing wall panelling/boarding with fillets any type any description complete all as specified and as directed. |
| 23 | Cutting of vegetable plant (girth not exceeding 300mm) from roof, terrace, chajjas etc digging out the roots and making good the surface in PCC 1:2:4 type B1 with surfaces finished to match complete including scaffolding etc, complete all as specified and as directed. |
| 24 | Disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading and disposal at an approved Municipal dumping ground outside Defence land (MoD land), for all leads and all lifts, complete all as specified and as directed by the Engineer-in-Charge.Notes:1. Photographic Evidence: The contractor shall submit clear photographic evidence in support of disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials, indicating the condition of the site before loading, during transportation and after unloading at the approved Municipal dumping ground. The photographs shall preferably be geo-tagged and date-stamped and shall form part of the record for verification and payment purposes. 2. Certification by Engineer-in-Charge: Completion of whole work in this BOQ shall be deemed to have been achieved only after certification by the Engineer-in-Charge that no building rubbish/malba, similar unserviceable, dismantled or waste materials have been left at the site and that the site has been thoroughly cleared and cleaned to his satisfaction. 3. Each load shall comprise a minimum carrying capacity of 5.00 cubic metres (Cum). Payment under this item shall be made on a per-load basis for loads conforming to the above minimum capacity and duly verified by the Engineer-in-Charge Please Enable Macros to View BoQ information |