| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and commissioning of Online Effluent Quality Monitoring System with complete Engineeing Panel, Cloud connector (Devices) for online server connectivity with all electrinics for monitoringparameters including COD, BOD, TSS and pH including online data transfer to HSPCB, CPCB and PHED website ondaily basis complete at Project. for online (continuous) measurement of PH, Total suspended solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (Spectral measurement in the UV-VIS range 200-720 mm) performing reagent and chemical free analysis with automatic cleaning of censor, single cables and power cables, local data acquisition and display of data on continuous basis for up linking the date to CPCB, HSPCB and PHED,Irrigation, TUV approved complete in all respects as Central per Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as Contained in scope of work in the notice inviting tender.1. Multi-Parameler measuring converter, for connecting upto 18 intelligent sensors, scope includes 6 analog outputs (014-20mA), wide-range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIsnge, for measurement in the inlet/ effluent/ BNR part of municipal waste water treatment plants at various Locations in Haryana State with integrated with automatic cleaning.2. Robust digital pH/ORP sensor for pH/ORP electrodes, withbuilt-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC), Cable length 100meter (minimum)3. Sensor adapter cable for all intelligent sensors, with IP69 water proof connection to the intelligent Sensor Netsystem, Cable length 100 meter (minimum).4. Data transfer to CPCB, HSPCB and PHED, Irrigation servers complete as per satisfaction of Engineer-in-Charge 5. Providing GSM 4G, 5G modem with mobile network Connectivity including network charges (1 year warranty) complete as per satisfaction of Engineer-in-Charge. No Extra Payment will be made for this job, It included all accesories and parts as required.(GST not included in this Item Rate) |
| 2 | Providing and lowering of 150 mm outer diameter UPVC threaded pipe (pressure rating 10 kg/cm²), duly ISI marked conforming to IS: 4985 for potable water supply applications including all jointing materials, handling, lowering, alignment and fixing, complete in all respects, as per directions of the Engineer-in-Charge.” |
| 3 | Supplying, installing, testing and commissioning of 800 mm sluice valve generally confirm to IS: 14846 and outside screw Rising Spindle of SS: 304, with length over flanges as per PD of IS: 14846 corresponding to BSEN -558/ISO 5752 basic series 3 in DI construction (GGG 40/IS1865 Gr.500/7) having metal seating (IS:318 Gr. LTB2 with 2% Nickel / SS AISI 304) Ø400 and above shall be fitted with ball thrust bearings, enclosed spur gear box, back seat bush as accessories for ease of operation, shall be coated internally and externally with epoxy liquid coating (minimum DFT 200 micron), valves Ø50 and above shall be rated PN1.0/1.6 as per final design of BOQ and flanges faced and drilled as per IS: 1538 table 4 and 6 /IS: 9523/BS EN 1092-2.Operation - including Electric Actuator (AUMA / ROTORK / MARSH / LandT/VTM/ABB with integral starter) complete in all respect as per site requirement and to the satisfaction of Engineer-in-charge, of make IVC Nasik/Kirloskar/KBL/Jupiter or any reputed brand.(Rates excluding GST) |
| 4 | Providing, supplying, installing, testing andcommissioning of 800 mm dia Non-Return Valve (NRV) of brands IVC Nasik/Kirloskar/KBL/Jupiter or any reputed brand, Valve upto 600mm dia. Shall be confirm to IS:5312 part 1 and above to IS:5312 part 2. Valve shall be in graded DI (IS:1865 Gr.500/7) with metal to metal (IS:318 Gr. LTB2 with 2% Nickel / SS AISI 304 stub pin and slants seat design. Valve above 600mm dia must be multi-door design with doors having minimum two integral lugs for hinging of the door. Valves Ø50 and above shall be rated PN1.0/PN1.6 as per final design of BOQ) and flanges faced and drilled as per IS: 1538 table 4 and 6 IS: 9523/BS EN 1092-2 complete in all respect as per site requirement and to the satisfaction of Engineer-in-charge (Rates exclusive GST) |
| 5 | Providing, supplying, installing, testing andcommissioning of 400 mm dia Non-Return Valve (NRV) of brands IVC Nasik/Kirloskar/KBL/Jupiter or any reputed brand, Valve upto 600mm dia. Shall be confirm to IS:5312 part 1 and above to IS:5312 part 2. Valve shall be in graded DI (IS:1865 Gr.500/7) with metal to metal (IS:318 Gr. LTB2 with 2% Nickel / SS AISI 304 stub pin and slants seat design. Valve above 600mm dia must be multi-door design with doors having minimum two integral lugs for hinging of the door. Valves Ø50 and above shall be rated PN1.0/PN1.6 as per final design of BOQ) and flanges faced and drilled as per IS: 1538 table 4 and 6 IS: 9523/BS EN 1092-2 complete in all respect as per site requirement and to the satisfaction of Engineer-in-charge (Rates excluding GST) |
| 6 | Providing, fixing, and commissioning of Cast Iron (CI) Sluice Gate 1000 x 1000 ,with Frame conforming to IS: 13349 (latest revision),with actuator, with S.S. 304 Grade Spindle and Seating Faces, D.I. Wedge Block with S.S. AISI :304 / CF8 Lining with all accessories including Lift Nut, Fastners, Extension Spindle, Guide Bracket, Coupling, Coupling, Electric Actuator (IP68, Integral Starter) Accessories (Companion Flanges, SSetc all complete in all respect up to the entire satisfaction of Engineer-in-Charge. (Rates excluding GST) |
| 7 | Design, manufacture, supply, installation, testing and commissioning of 160 HP VFD Starter Panel, Star Delta By-pass type suitable for non-clog submersible pumps, Indoor PTTA type, suitable for operation on 415 volts, 3 phase, 50 Hz A? supply system, fabricated out of 14/16 SWG CRCA sheet steel enclosure of suitable thickness, floor mounted, free standing, dust and vermin proof, single front compartmentalized construction, complete with seven tank anti-corrosive chemical treatment process including degreasing, rinsing, derusting, phosphating and passivation followed by powder coated finish in Siemens grey shade. The panel shall be manufactured by reputed and approved makes such as Siemens, Schneider Electric, ABB, LandT, Crompton Greaves, Legrand, Danfoss or any other reputed equivalent brand approved by the Engineer-in-Charge. The panel shall be complete with 320A TPN electrolytic grade aluminium bus bars insulated with heat shrinkable PVC sleeves along with sultable supports, finger supports, insulators, hardware, nut bolts, spring washers and all associated accessories. The panel shall comprlse 320A, 36kA TP MCCB incomer with overload and short circuit protection complete with spreader set and extended rotary handle, The panel shall be provided with 140A TP star contactor, 250A TP delta/main contactors, 250A TP by-pass contactors, auxiliary contactor, 160 HP heavy duty VFD, line choke, PLA relay, selector switches, start/stop push buttons, ON/OFF/TRIP indicating lamps, multiturn potentiometer for VFD control, digital ammeter with selector switch arrangement, esin cast CTs, CT shorting links, terminals and neutral link complete in all respects, The panel shall Include complete internal metering, control and power wiring using copper control wires wIth ferrules, thlmbles, aluminium lugs, PVC cable ducts, cable ties, casing- capping, C channels, D channels and all necessary accessorles required for satisfactory and trouble-free operation. The enclosure shall be complete with neoprene gasket, panel locks, lifting hooks, nut bolts and all other mounting hardware. The panel shall be fully wired, factory assembled, tested and ready for installation. Routine tests such as visual inspection, dimensional checks, functional checks and HV/Megger tests shall be carried out as per relevant IS standards. The complete work shall be executed strictly In accordance with approved technical specifications, bill of materials and manufacturer`s offer and to the entire satisfactlon of the EngIneer-In-Charge ( Rates excluding GST) |
| 8 | Fabrication of M.S. pipes and specials as per IS specifications with inside and outside epoxy coating as per IS 3589 code or any other relevant IS codes , duly tested for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site, and stacking etc. complete as for direction of Engineer-in-Charge(Rates excluding GST) |
| 9 | Fabrication of M.S. pipes and specials as per IS specifications with inside and outside epoxy coating as per IS 3589 code or any other relevant IS codes , duly tested for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site, and stacking etc. complete as for direction of Engineer-in-Charge(Rates excluding GST) |
| 10 | [10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate] |
| 11 | [10.33.1]Providing and laying of brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1. 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 12 | [10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate] |
| 13 | [10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [Through Rate] |
| 14 | [10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate] |
| 15 | [11.25.1]Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1. Flush / Ruled/ Struck or weathered pointing [Through Rate] |
| 16 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 17 | [11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate] |
| 18 | [11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works [Through Rate] |
| 19 | [11.71.1]Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 20 | [11.73.2]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 2. On concrete work [Through Rate] |
| 21 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 22 | [11.8.1]12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) [Through Rate] |
| 23 | [11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 24 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 25 | [12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 26 | [12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 27 | [12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Through Rate] |
| 28 | [12.167.1]Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge 1. Anodized (AC 15 ) aluminium [Through Rate] |
| 29 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 30 | [13.28]Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 31 | [13.29.1]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete [Through Rate] |
| 32 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 33 | [13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate] |
| 34 | [17.13]Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications [Through Rate] |
| 35 | [17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate] |
| 36 | [20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d [Through Rate] |
| 37 | [20.135.49]Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make and design standard of following dia complete (including jointing and jointing material ) including all material, labour, testing and commissioning along with pipe line as per prescribed Technical Specifications confirming to IS 14846 : 2000 and as per direction of Engineer-in-charge. 49. Electrically Operated & SCADA Compatibleclass PN 1.6400 mm dia [Through Rate] |
| 38 | [20.155.7]Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. completein all respect as per Technical Specifications and specified makes as perdirection of Engineer in charge. 7. EMF 400 for DN 400 mm [Through Rate] |
| 39 | [20.156]Providing, fabricating and erecting hand railing for walkway, top dome slab, balcony, staircase and landing consist of two rows ( one at top and other at middle level) of 20 mm GI pipe class-B and 900 mmhigh vertical angle 65X65X6 mm at spacing 1.50 m c/c including welding, threading, applying a priming coat of approved steelprimer and embedding in cement concrete floor complete in all respect as per stipulated specification and specified makes as per the direction of the Engineer in charge. [Through Rate] |
| 40 | [20.4.5]Jointing cast iron socketed pipes, valves and specials with run lead caulked joints excluding cost of lead and yarn but including cost of labour, fuel and tools etc. Tested complete. 5. 200 mm i/d pipe [Through Rate] |
| 41 | [20.5.5]Making flanged joints for cast iron pipes, valves or specials 5. 200 mm internal diameter of pipe, values or specials [Through Rate] |
| 42 | [20.76.13]Design, Supply, Erection, Testing and Commissioning outdoor type 3 phase transformer (input) 11KVA /433 V (3phase output) -250 V (single phase output) Oil immersed naturally cooled, energy efficiency level-2 including cost of earthlings as per DHBVN/ UHBVN norms, inspection charges, Connecting material i.e. lugs thimbles complete in all respect satisfaction to Engineer-in-Charge(Inspection certificate will be issued by Chief Electrical Inspector of Nigam & inspection charges will be borne by agency. 13. 600 KVA [Through Rate] |
| 43 | [21.121.20]Providing, lowering, laying, cutting, jointing and testing RCC pipe class NP-3 as per IS- 458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with 3 mm thick HDPE Lining and manufactured through vertical viberated casting process with rubber rings ISI marked anti termite confirming to IS 5382 as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting ofconcrete beds and side of trenches, if required jointing with rubber rings intrenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints, cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.45, and item 21.46 including cartage loading and unloading complete in all respect, the internal diametre of the sewer being- Note : E/w to be measured and paidseparately. 20. 2400 mm i/d [Through Rate] |
| 44 | [21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate] |
| 45 | [22.1.4]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 4. White vitreous chinaware Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap [Through Rate] |
| 46 | [22.102.2]Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 2. 150 mm diameter [Through Rate] |
| 47 | [22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate] |
| 48 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 49 | [22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate] |
| 50 | [22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate] |
| 51 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 52 | [22.16]Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint [Through Rate] |
| 53 | [22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate] |
| 54 | [22.202]Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg [Through Rate] |
| 55 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 56 | [22.211]Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. [Through Rate] |
| 57 | [22.24.1]Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1. W.C. pan with ISI marked white solid plastic seat and lid [Through Rate] |
| 58 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 59 | [22.51.1.1]Providing and fixing soil, waste and vent pipes : 1.1. 100 mm dia Sand cast iron S&S pipe as per IS: 1729 [Through Rate] |
| 60 | [22.88.1]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 1. 15 mm dia nominal bore [Through Rate] |
| 61 | [23.10]Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. [Through Rate] |
| 62 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 63 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] |
| 64 | [23.22.4.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.12. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate] |
| 65 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 66 | [23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE [Through Rate] |
| 67 | [23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate] |
| 68 | [23.28.17.3]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 3. 100 watt [Rate] |
| 69 | [23.28.20.2]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K(As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 1. Control and monitor LED luminaries with bi directional control ( Status, Fault, Alarm, dimming level, wattage, energy)2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge.5. should be controlled through auto/ manual6. Programmable level of not less than 48 different light intensity settings,7. Inbuilt repeater and relay signals function to other controllers 2. 50 Watt [Rate] |
| 70 | [23.28.31.10]Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Deg C, 50% RH and at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH and at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof and dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total), KW and provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C and E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phase and Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring. 10. 200 KVA [Rate] |
| 71 | [23.28.31.15]Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Deg C, 50% RH and at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH and at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof and dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total), KW and provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C and E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phase and Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring. 15. 750 KVA [Rate] |
| 72 | [23.3.1.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate] |
| 73 | [23.3.4.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group B [Through Rate] |
| 74 | [23.3.5.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B [Through Rate] |
| 75 | [23.32.1.7]Automatic Power Factor Correction (APFC) SystemSupply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V plus 10 %, 50 Hz AC System for Ambient temperature -5°C to plus 40°C, fabricated in compartmentalized designed made of CRCA sheet steel of 2.0mm thick for framework and covers, 3 mm thick for gland plate i/c cleaning and finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 and 2) APFC Panel shall be in compliance with IS :16636 and CPWD Specifications etc. as per below details(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments and Indications i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR and above) with Communication Ethernet/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT`s accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.i) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.ii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V and I, Frequency.iii) Suitable rating control transformer shall be provided for control and indication circuit.i) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB`s.ii) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire.(B) Bus Bars1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification.(C) Outgoings (APFC Section)Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor, the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:(i) Capacitor bank ratings and stages shall be as per(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation and 150% linearity in series with Capacitor. 7. 200 KVAR [Rate] |
| 76 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 77 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 78 | [23.8.1.1]FITTING AND ACCESSORIES 1.1. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet. [Through Rate] |
| 79 | [23.8.1.2]FITTING AND ACCESSORIES 1.2. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Wall socket 5 amp on existing sheet. [Through Rate] |
| 80 | [23.8.1.3]FITTING AND ACCESSORIES 1.3. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. 15 amp. switch on existing sheet. [Through Rate] |
| 81 | [23.8.1.4]FITTING AND ACCESSORIES 1.4. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. 6 pin 15 multi socket on existing sheet [Through Rate] |
| 82 | [23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate] |
| 83 | [23.8.2.2]FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick [Through Rate] |
| 84 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 85 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 86 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 87 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] |
| 88 | [24.11.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 100. 400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 89 | [24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 90 | [24.13.79]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 79. 185 Sq mm 3 core (UnArm.) [Through Rate] |
| 91 | [24.16.8]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 8. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 240 Sq mm 3 core [Through Rate] |
| 92 | [24.2.2.1]LT CABLE 2.1. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:-2.5 Sq mm to 10 Sq mm 2 to 4 Core [Through Rate] |
| 93 | [24.4.1.3]STREET LIGHT 1.3. 3 metres long 50 mm dia pole duly embedded 0.6 m below ground level. 6 metres long 65 mm dia pole duly embedded 1 m below ground level. [Through Rate] |
| 94 | [24.4.3]STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. [Through Rate] |
| 95 | [24.4.4.2]STREET LIGHT 4.2. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole above 4.5 metres but up to the height of 7 metres. [Through Rate] |
| 96 | [24.4.5]STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. [Through Rate] |
| 97 | [24.4.7.1]STREET LIGHT 7.1. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia [Through Rate] |
| 98 | [27.13]Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and MoRTandH Specifications 1600 & 2200. [Through Rate] |
| 99 | [33.15]Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 100 | [33.16.3]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia [Through Rate] |
| 101 | [33.17.1]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 1. 100 mm clamp [Through Rate] |
| 102 | [33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate] |
| 103 | [33.6.1.1]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.1. All types of soil 300 mm dia [Through Rate] |
| 104 | [33.9.3]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia [Through Rate] |
| 105 | [36.38]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 13386) 50 ltr. Capcity mechanical foam trolley mounted mobile fire extinguisher including horn, discharge hose pipe and initial charge of AFFF( Aqueous Film Forming Foam) for D.G Set complete in all respect. [THROUGH RATE] |
| 106 | [36.40]Providing, fixing, testing and commissioning of 50 KG DCP (Dry Chemical Powder) Trolley type fire extinguisher as per (IS 160181) with branch pipe having 10 mtr length complete in all respect. [THROUGH RATE] |
| 107 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 108 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 109 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 110 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 111 | [6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 112 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 113 | [6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate] |
| 114 | [6.22.2.2]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.2. All works up to Plinth Level : M-15 grade plain cement concrete. (cement content considered @ 240 kg/cum) [Through Rate] |
| 115 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 116 | [6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate] |
| 117 | [6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate] |
| 118 | [6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate] |
| 119 | [6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate] |
| 120 | [6.29.3]Centering and shuttering including strutting, propping etc. and removal of form work for : 3. Columns, piers, abutments, pillars, posts and struts [Through Rate] |
| 121 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 122 | [6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate] |
| 123 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 124 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 125 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 126 | [6.8.1]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 1. 50 mm thick [Through Rate] |
| 127 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 128 | [9.33]Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( plus 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. [Through Rate] |
| 129 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 130 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate] Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail