| 1 | Clearing Grass and Removal of Rubbish |
| 2 | Earth work in excavation of foundation trenches in ordinary soil (Vide classification of soil item-A) and disposal of excavated earth so obtained (50M away from the edge of the trenches) with initial lead of 150M and initial lift of 1.5M as per specification and direction of E/I. |
| 3 | Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (Vide classification of soil item-C) and disposal of excavated materials so obtained (50M away from the edge of the trenches) with initial lead of 150M and initial lift of 1.5m as per specification and direction of E/I. (Soft Rock where blasting is not required). |
| 4 | Earth work in filling foundation trenches or back filling of masonry structures with suitable earth in layers not exceeding 150mm thick well watered, rammed and fully compacted and finally dressed with earth obtained from excavation of foundation trenches and kept at a lead of 30m and initial lift of 1.5m complete as per specification and direction of E/I. |
| 5 | Supplying labour and equipment for digging well vide classification of soil item-A including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specificition and direction of E/l.Earth Work upto 3 M depth below GL |
| 6 | Extra for additional lift of 1M over the initial lift of 3 metres as per specificition and direction of E/l.3.00 M to 4.00 M |
| 7 | Extra for additional lift of 1M over the initial lift of 3 metres as per specificition and direction of E/l.4.00 M to 5.00 M |
| 8 | Extra for additional lift of 1M over the initial lift of 3 metres as per specificition and direction of E/l.5.00 M to 6.25 M |
| 9 | Supplying material and labour for providing R.C.C. Well Curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specificition and direction of E/l. |
| 10 | Supplying material and labour for fixing 20mm dia M.S. bar steps in steining well of 0.30m interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I. |
| 11 | Supplying equipment and labour for back filling the excavated earth around steining well all complete as per specificition and direction of E/l. |
| 12 | Earth work in excavation in foundation trenches in hard soil (vide classification of soil item - A+B) and disposal of excavated earth as obtained to a distance up to 50M all complete as perbuilding specification and direction of E/I. |
| 13 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 14 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 15 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 16 | Supplying and laying sand filter blanketing in horizontal portion of the dam as per design and drawing with watering, compaction including cost of sand, royalty all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/I. |
| 17 | Supplying and laying gravel filter (size 5mm to 15mm) in filter blanket and in the toe drain (in horizontal portion) of the dam as per design, drawing including the cost of materials royalty and all taxes etc. but excluding the cost of carriage all as per specification and direction of E/I. |
| 18 | Supplying and laying good quality of stone metal filter (20mm to 63mm size) in the rock toe, heel trenches, toe drain as per design and drawing including the cost of materials, royalty, all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/I. |
| 19 | Supplying laying boulder in rock toe, heel trenches of the dam as per design, drawing including the cost of materials royalty and all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/I. |
| 20 | Labour charge for fitting and fixing 600mm x 300mm C.I. grating in the steining walls of intake well as per specification and direction of E/I. |
| 21 | Providing designation 75B brick work in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth, curring, taxes and royalty all complete as per builiding specification and direction of E/I. |
| 22 | Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l. |
| 23 | Providing rough dressed random rubble stone masonry in cement mortar (1:4) in foundation with approved quality of coarse sand of requisite F.M. (2.5 to 3.0) washed and screened with raking out joints,curing, scaffolding and its removal wherever required including royalty and all taxes etc. complete job as per specification and direction of E/I. |
| 24 | Providing rough dressed random rubble stone masonry in cement mortar (1:4) in superstructure with approved quality of coarse sand of requisite F.M. (2.5 to 3.0) washed and screened with raking out joints,curing, scaffolding and its removal wherever required including royalty and all taxes etc. complete job as per specification and direction of E/I. |
| 25 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.25mm thick |
| 26 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 27 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 28 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 29 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 30 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 31 | Providing shuttering including strutting, proping etc.and its removal after use in foundation as per specifications and direction of E/I. |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns etc. for mass concrete. |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform. |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form work for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases. |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges. |
| 38 | Providing Tor steel reinforcement as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.8mm dia bar |
| 39 | Providing Tor steel reinforcement as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.10mm dia bar |
| 40 | Providing Tor steel reinforcement as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.12mm dia & above bar |
| 41 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I. |
| 42 | Providing and fixing fan hook of 16mm dia TMT M.S. bar 1 meter long bent to required size and shape placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. |
| 43 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 44 | Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint all complete as per building specification and direction of E/I. |
| 45 | Supplying, fitting and fixing 20 guage G.C.I. sheet gate fitted on M.S. angle frame of size 60x60x6mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 46 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red, Area of slab over 0.50 sqm. |
| 47 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 48 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement |
| 49 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 50 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 51 | Providing and laying doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 52 | Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 53 | Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 54 | Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 55 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 56 | Providing 6mm cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 57 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 58 | Providing 25 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 59 | Providing 12mm water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water all complete as per building specification and direction of E/I. |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 61 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 62 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding, curing and taxes all complete as per building specification and direction of E/I. Quantity vide item no. 11 |
| 63 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 64 | Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 65 | Providing weep hole with dry graded stone filter of 20mm to 40mm size in abutment and wing wall as per specificatin and direction of E/I. |
| 66 | Supplying 300mm dia NP2 R.C.C. Hume Pipe with Collar as per I.S.S. 458-1971 |
| 67 | Labour for laying, fitting and fixing 300mm dia NP2 hume pipe with collors in line, level and grade, as well as providing approved jointing material and joints properly filled to make them water proof, all complete, as per specification and direction of E/I. |
| 68 | Hire charge of diesel operated pump (upto 10 HP) for bailing out of water during construction all complete as per specification and direction of E/l. |
| 69 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 70 | Supply of G.C.I. Sheet (thickness in mm)(v) 0.35mm thick |
| 71 | Labour for fitting and fixing G.C.I. or C.A. sheet roofing in proper slope including the cost of \\"J\\" or \\"L\\" hooks, limpet and bitumen washers, carriage of sheet to work site, and taxes all complete as per building specification and direction of E/I. |
| 72 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes. |
| 73 | Supplying, fining and fixing viterous white glazed earthen ware I.W.C of Parry Hindustan or any other I.S.S approved make with 100mm H.C.I \\"p\\" trap 15 liters C.I. or C. pull and let go flushing cistern of names or other I.S.S equivalent make, complete with all fittings. C.I or C.C brackets 32mm alkathene/P.V.C telescopic flush, pipe about 2M long with one brass coupling and clamps G.I chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I body brass spindle stope cock of weight not less than 50 grins. 15 mm P.V.C connection pipe 450mm long and the exposed pipe and cistern etc. all complete as per specification and direction of E/I. 580mm long with 10 litre low level P.V.C. cistern |
| 74 | Supplying, fitting and fitting vitreous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or M.S. brackets 32m C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling etc. all complete as per specification and direction of E/I. |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20mm dia |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 32mm dia |
| 77 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (wt. not less than 350 gms.) with extra socket all complete as per specification and direction of E/I. |
| 78 | Providing and fixing brass/C.I. stop cock of approved quality as per specification and direction of E/I. Brass stop cock - 15mm dia |
| 79 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 80 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door - 110mm |
| 81 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° - 110mm |
| 82 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) - 110mm |
| 83 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 84 | Carriage of materials by diesel truck including loading at source, unloading at work site and stacking properly, labour etc. all complete as per direction of E/I.Cement |
| 85 | Stone Chips |
| 86 | Stone Metal |
| 87 | Boulder |
| 88 | Hume Pipe - 300mm dia |
| 89 | Steel |
| 90 | Bricks |
| 91 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group-B |
| 92 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2x1.5 sq mm + 1x1.5 sq mm earth wire |
| 93 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 94 | Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm PVC conduit |
| 95 | Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm PVC conduit |
| 96 | Supplying, fitting and fixing of metal box of 150mm x 150mm x 60mm size etc. as required with taxes all complete as per approved design, drawing and electrical specification and direction of E/I. 75mm x 75mm x 50mm |
| 97 | Supplying, fitting and fixing of metal box of 150mm x 150mm x 60mm size etc. as required with taxes all complete as per approved design, drawing and electrical specification and direction of E/I. 147mm x 93mm x 47mm |
| 98 | Supplying, fitting and fixing of metal box of 150mm x 150mm x 60mm size etc. as required with taxes all complete as per approved design, drawing and electrical specification and direction of E/I. 121mm x 173mm x 48mm |
| 99 | Supplying, fitting and fixing of following size piano type switch and socket on the existing switch box/cover including taxes all complete as per approved design, drawing and electrical specification and direction of E/I.5/6 amp switch |
| 100 | Supplying, fitting and fixing of following size piano type switch and socket on the existing switch box/cover including taxes all complete as per approved design, drawing and electrical specification and direction of E/I.15/16 amp switch |
| 101 | Supplying, fitting and fixing of following size piano type switch and socket on the existing switch box/cover including taxes all complete as per approved design, drawing and electrical specification and direction of E/I.3 pin 5/6 amp socket outlet |
| 102 | Supplying, fitting and fixing of following size piano type switch and socket on the existing switch box/cover including taxes all complete as per approved design, drawing and electrical specification and direction of E/I.5 pin 15/16 amp socket outlet |
| 103 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 104 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 amps Double Pole |
| 105 | EARPIPCHAR - Earthing with G.I. earth pipe 4.5 mtr long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt etc. as required with taxes all complete as per approved design, drawing and electrical specification and direction of E/I. |
| 106 | Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 107 | Supplying and fixing of 48\\" (1200mm) Ceiling Fan |
| 108 | Supplying and fixing of holder type LED - 9/10 watt |
| 109 | 10 HP electric motor (Approved Rate) |
| 110 | Intake Well to Pump4\\" dia M.S. Suction pipe (C.E. Lt-2873, DT-31/12/2013, (item-1) |
| 111 | 4\\" dia C.I. Foot Valve (Common Part-A, M-1063, (pg-134) |
| 112 | 4\\" dia G.I. Bend - (Common Part-A, M-930(A-viii), (pg-92) |
| 113 | 4\\" dia G.I. Flange (C.E. Lt-2873, DT-31/12/2013, (item-38) |
| 114 | 4\\" dia G.I. Nipple (Common Part-A M-930(J-ix), (pg-94) |
| 115 | Pump to Junction and Surge Tank4\\" dia M.S. delivery pipe (C.E. Lt-2873, DT-31/12/2013, (item-1) |
| 116 | 4\\" dia G.I. nipple (Common Part-A,M930(J-ix),pg-94) |
| 117 | 4\\" dia G.I. Flange (C.E. Lt-2873,dt-31/12/2013, item-39) |
| 118 | 4\\" dia N.R. Valve (Common Part A M-926(ix) (pg-91) |
| 119 | 4\\" x 8\\"/10\\" Reducer (C.E. Lt-2873,dt-31/12/2013, item-96) |
| 120 | 10\\" M.S. Pipe (C.E. Lt-2873,dt-31/12/2013, Sl. No.-5) |
| 121 | 4\\" G.I. Reducing Tee (Common Part-A, M930,(D)-(x), Pg-92 |
| 122 | 10\\" H.D.P.E Rising main pipe (grade-PE80-PN10)(Common Part-A, M-1029, PG-105) |
| 123 | 10\\" C.I. Non-Returning Valve (Common Part-A, M1039, (A)-6, Pg-118) |
| 124 | 10\\" Flange (C.E. Lt-2873,dt-31/12/2013, item-43) |
| 125 | 10\\" M.S. bend(C.E. Lt-2873,dt-31/12/2013, item-43) |
| 126 | Surge Tank to Platform for Water Storage Tank6\\" M.S. pipe (C.E. Lt-2873, dt-31/12/2013, Sl.No.-3) |
| 127 | 6\\" G.I. bend(Common Part-A, M930, (A)-(xi), Pg-92) |
| 128 | 6\\" dia G.I Sluice Valve(Common Part A M1039(B)6, Pg-120) |
| 129 | 6\\" G.I Socket (Common Part A M930(E-xi) Pg93) |
| 130 | 4\\" PVC Ball Valve (L.S.) |
| 131 | 4\\" PVC Tee(C.E. Lt-2873, dt-31/12/2013, Sl.No.-105) |
| 132 | 4\\" PVC Tail piece(C.E. Lt-2873, dt-31/12/2013, Sl.No.-65) |
| 133 | 4\\" PVC Bend (C.E. Lt-2873, dt-31/12/2013, Sl.No.-111) |
| 134 | Solvent Cement(Sl No.134) (C.E. Lt-2873,dt-31/12/2013, item-134) |
| 135 | M-Seal(Sl No.136) (C.E. Lt-2873,dt-31/12/2013, item-136) |
| 136 | Pipe layingE/W in excavation in foundation trenches in ordinary soil -do- -do- all complete job as per specification and direction of E/I. |
| 137 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 138 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 139 | Carriage of Sand |
| 140 | Supplying labour and tools for laying and jointing A.C. pressure pipe in trenches as per I.S.S. with G.I. detachable joints with \\"O\\" rings, including providing night guard, barrier and red light to safeguard against accident all complete as per specification and direction of E/I. (A.C. pressure pipe with C.I. detachable jointing with \\"O\\" rings will be supplied departmentally free of cost)250mm I.D. |
| 141 | Labour charge for fitting & fixing of 110mm foot valve |
| 142 | Labour charge for fitting & fixing P.V.C. Tail Piece |
| 143 | Labour charge for fitting & fixing of G.I. Bend |
| 144 | Labour charge for fitting & fixing of reducer |
| 145 | Labour charge for fitting & fixing of 150mm P.V.C. Bend |
| 146 | Labour charge for fitting & fixing of P.V.C./G.I. Tee |
| 147 | Labour charge for fitting & fixing of N.R. valve & sluice valve |
| 148 | Labour charge for threading of M.S. pipe |
| 149 | Energification including cost of Transformer & Energy Connection - L.S. (Amount will be deposited to the Electricity Department) |
| 150 | Goods & Services Tax (G.S.T.) - 18% |
| 151 | Labour Cess - 1% Please Enable Macros to View BoQ information |