| 1 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 7 | 25 mm |
| 8 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 amps switch |
| 10 | 3 Pin 5/6 A. socket outlet |
| 11 | 15/16 amps switch |
| 12 | 6 Pin 15/16 A. socket outlet |
| 13 | DSR item no. 8.6.10 LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, (As per Complete Item No. 5 of the DNIT). |
| 14 | 36 watt |
| 15 | DSR item no. 8.7.10 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 6 of the DNIT). |
| 16 | 36 watt |
| 17 | DSR item no.8.9.5 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 7 of the DNIT). |
| 18 | 18- 22 watt |
| 19 | DSR item no.8.16.4 LEDFlood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying,installation,Testing&CommissioningofFlood Light,powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, (As per Complete Item No. 8 of the DNIT). |
| 20 | 150 Watt |
| 21 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 9 of the DNIT). |
| 22 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. (As per Complete Item No. 10 of the DNIT). |
| 23 | Supply & erection of Cabin Fan 16” sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. (As per Complete Item No. 11 of the DNIT). |
| 24 | Supply and Erection of LED Post Top Lantern fittings made of cast aluminium housing with power to be mounted on directly on inbuilt Heat sinks. A UV stabilized PC/PMMA diffuser is provided for Glare Free Lighting with high visual comfort to complete with Electronic LED Driver Power supply & related accessories with the following specifications to be installed on existing pole. (As per Complete Item No. 12 of the DNIT). |
| 25 | DSR item No.9.2.3 BrushLessDirectCurrent(BLDC)FanwithoutRemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, (As per Complete Item No. 13 of the DNIT). |
| 26 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) Please Enable Macros to View BoQ information |