| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/REPLACEMENTOF FILTER MEDIA, WATER TREATMENT PLANT INCLUDING MAIN PIPE LINES, CONNECTED PIPES & ALLIED WORKS IN VARIOUS PUMP HOUSES AT AGE CHARDUAR UNDER GE(N) TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8284/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | S&F in repair GI tubing medium grade 200 mm dia as lateral and header pipe complete with heavy duty fittings as per existing/as required at site and painting the same with black bituminous paint complete all as specified and directed. |
| 3 | S&F in repair GI tubing medium grade 150 mm dia as lateral and header pipe complete with heavy duty fittings as per existing/as required at site and painting the same with black bituminous paint complete all as specified and directed. |
| 4 | S&F in repair GI tubing medium grade 100 mm dia as lateral and header pipe complete with heavy duty fittings as per existing/as required at site and painting the same with black bituminous paint complete all as specified and directed. |
| 5 | S&F in repair GI tubing medium grade 80 mm dia as lateral and header pipe complete with heavy duty fittings as per existing/as required at site and painting the same with black bituminous paint complete all as specified and directed. |
| 6 | S&F in repair GI nozzles made out of 100 mm GI pipe of length 0.6 Mtr each in sedimentation tank complete with provision of cap on top (as per existing) and fixing with 200/150 mm GI pipe medium grade (lateral and Header pipe) and painting the same properly with black bituminous paint including taking down/up of old unserviceable existing nozzles complete all as specified and directed. (Note : Cost of necessary welding if required at site is deemed to be included in the quoted rates) |
| 7 | S&F in repair GI nozzles made out of 80 mm GI pipe of length 0.6 Mtr each in sedimentation tank complete with provision of cap on top (as per existing) and fixing with 200/150 mm GI pipe medium grade (lateral and Header pipe) and painting the same properly with black bituminous paint including taking down/up of old unserviceable existing nozzles complete all as specified and directed. (Note : Cost of necessary welding if required at site is deemed to be included in the quoted rates) |
| 8 | S&F hand operated butterfly valve of size 150 mm dia, class-1, conforming to type PN 1.6 of IS:13095 -1991 of pressure not less than 15 Kg / Sqcm complete with flanges, bolts, nuts, gasket etc as per specifications complete in all respect all as specified. |
| 9 | Supply and fixing hand operated butterfly valve of size 100 mm dia, class-1, conforming to type PN 1.6 of IS:13095 -1991 of pressure not less than 15 Kg / Sqcm complete with flanges, bolts, nuts, gasket etc as per specifications complete in all respect all as specified. |
| 10 | S&F in repair /replacement Non return valve vertical/horizontal type (Suitable as per existing valve) with gasket bolts, nuts and washers in position of 150 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 11 | S&F in repair /replacement Non return valve vertical/horizontal type (Suitable as per existing valve) with gasket bolts, nuts and washers in position of 100 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 12 | Supply & Fixing in replacement of Liquid chlorine dozer,Electronic dozing Unit with Postive displacement diaphram type actuated by a solinoid and a solid state Pulsor with adjustable dozage output, suitable for maximum injector Pressure of 7.5 Kg / CmSq and maximum dozage of 4 Ltr/Hrs including LDPE /FRP Coated solution tank of 100 Ltr capacity fitted with motor, gear agitator, level gauge, lid and inlet / outlet connection and all accessories such as Hypalon Diaphram teflon lined,Polypropylen head,Body,Disc,Suction Pipes,Spaceers,PVC Foot valve and syphon valve complete etc,all as specified and as directed Make : make as approved by Engr-in-charge |
| 13 | M&L for repair & replacement of unsv spare parts in Alum/Soda dozer,Electronic dozing Unit with Postive displacement diaphram type actuated by a solinoid and a solid state Pulsor with adjustable dozage output, suitable for maximum injector Pressure of 7.5 Kg / CmSq and maximum dozage of 4 Ltr/Hrs including LDPE /FRP Coated solution tank of 100 Ltr capacity fitted with motor, gear agitator, level gauge, lid and inlet / outlet connection and all accessories such as Hypalon Diaphram teflon lined,Polypropylen head,Body,Disc,Suction Pipes,Spaceers,PVC Foot valve and syphon valve complete etc,all as specified and as directed Make : make as approved by Engr-in-charge |
| 14 | S&F in replacement pressure gauge with isolating valve and siphon 7Kg x 4\\" dial premium quality material body of pressure rating as per sample/as per site complete all as directed by Engineer-In-charge. |
| 15 | Labour for taking out of old and not reuseable supporting bed(pebbles/gravel) and media bed(MnO2/Anthracite/Activated carbon) in filter plant or sedimentaion tank from the Various Pump houses under AGE Charduar all complete as specified and directed. |
| 16 | Supply and laying in layer MNO2 (Maganese dioxide) compound in filter media plant after isolate the system/bypass the system and opening of filter media as per instruction given by Engineer-In charge complete all as specified and directed . |
| 17 | Supply and laying in layer Anthracite coal in filter media plant after isolate the system and opening of filter media as per instruction given by Engineer-In charge complete all as specified and directed . |
| 18 | Supply and laying in layer crushed gravel of 2-6 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing gravels as per instruction given by Engineer-In charge complete all as specified and directed . |
| 19 | Supply and laying in layer activated charcoal in activated carbon filter media plant after isolating the system opening of filter media complete all as specified and directed |
| 20 | Supply and laying in layer pebbles of 12-20 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing gravels as per instruction given by Engineer-In charge complete all as specified and directed . |
| 21 | Supply and laying in layer pebbles of 25-40 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing pebbles as per instruction given by Engineer-In charge complete all as specified and directed .Note: Filter media will be replaced as per direction of OEM |
| 22 | M&L for applying two coats of approved quality anti corrosive bituminous paint suitable for potable water to internal surface of the sedimentation tank, filter bed & filtered water tank , inner surface gravity filter incl all nozzle, pipes etc all as specified and directed (Capacity Upto 40000 Glns,In Various pump houses under AGE Charduar) |
| 23 | M&L for testing of water sample after replacement of Filter media from various installation as speciefied and directed by the Engineer-in-Charge and test the sample as per IS 10500:2012 at PHE lab of ASSAm Govt. (NABL accredited) or any other NABL accredited laboratory and submit the test report to Engineer-in-ChargeNote: Quoted rate is deemed to be inclusive of collection of water at sumps/OHT's at different location in suitable container and submit for testing. The above specified job shall be carried out at pump houses Under AGE Charduar . |
| 24 | M&L for preparation for painting of external old painted surfaces of filtration plant ( Iron removal filter , Multi grade filter , oxidation chamber , Activated carbon filter and associate filtration pipe line up to pump motor, by scrubbing ,cleaning the outer surfaces ,removing dust , scaling, Carbon over the surfaces and applying the two coat of weatherproof paint of approved colour ( Approved by Engineer-In -charge) with spray machine including writing name of filter , direction of flow with colour code etc complete all as directed by Engineer-in-Charge.(For Pump houses Under AGE Charduar) |
| 25 | M&L for painting(type and quality of paint recommended and approved by engineer-in charge) to delivery pipe(any type any size) of RCC O/H reservoiror , steel over head reservoiror as per colors code with one coat of synthetic enamel paint with indication of direction of flow complete all as directed by Engineer-In-charge forVarious Pump houses Under AGE Charduar |
| 26 | Supply only Calcium hypochlorite granuels of capacitance 65-70(Purichlor).Make: Shree Rayalaseema Hi -Strength Hypo Ltd or equivalent E-in-C approved Make. |
| 27 | Supply only Soda Ash. Of ISI approvedMake as per specified and directed by Eng-in-Charge. Make- TATA Chemicals Limited Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |