Tender For Special Repair To Bldg. No P-391, P-392 And P-393 And Provision Of Power Supply Arrangement For Boom Barrier At Shibpur, Under Ge(S) Diglipur
Tender Value
39 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
11 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg. No P-391, P-392 And P-393 And Provision Of Power Supply Arrangement For Boom Barrier At Shibpur, Under Ge(S) Diglipur
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frame with shutter without taking off shutter from the frame exc. 1.50 sqm but not exc. 4 sqm each & removing from site complete all as specified and as directed. |
| 2 | Taking down chowkhats or frame with shutter without taking off shutter from the frame n.exc. 1.50 sqm each & removing from site complete all as specified and as directed. |
| 3 | Taking down shutter of any description exc. 1 Sqm & n. exc. 2 Sqm each & removing from site of work complete all as specified and as directed. |
| 4 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the framriming/tack coat with bituminous primer at 10 kg per 10 sq metre complete all as specified and as directed. |
| 5 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. |
| 6 | S&F for 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 7 | S&F for 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete all as specified and as directed. |
| 8 | S&F for Aluminium anodised, barrel tower bolts of extruded section and fixed of 150mm long complete all as specified and as directed. |
| 9 | S&F in repairs Aluminium anodised, barrel tower bolts of extruded section and fixed of 150mm long complete all as specified and as directed. |
| 10 | S&F in 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 11 | S&F in repairs 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 12 | S&F for Aluminum handles, cast type anodisd of 150mm long complete all as specified and as directed. |
| 13 | S&F in repairs Aluminum handles, cast type anodisd of 150mm long complete all as specified and as directed. |
| 14 | S&F for Floor door stopper 150mm over all length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 15 | S&F in repairs Floor door stopper 150mm over all length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 16 | S&F in repairs Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed. |
| 17 | Dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and as directed. |
| 18 | M&L for Coloured/dark shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick on floor surfaces, in cement and sand mortar (1:4) complete all as specified and as directed. |
| 19 | Ditto as per item no above but as in skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 10mm thick on fair faces of wall surfaces, in cement and sand mortar (1:4) complete all as specified and as directed. |
| 20 | M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick on floor surfaces, in cement and sand mortar (1:4) complete all as specified and as directed. |
| 21 | M&L for Glazed ceramic colour tiles in vertical surface (300x 200x 7 mm) thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including rendering 10mm thick on fair faces of wall surfaces, in cement and sand mortar (1:4) complete all as specified and as directed. |
| 22 | Diamantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 23 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 24 | ditto as per item no23 above but based Plain steel sheet |
| 25 | S&F for 15mm steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down complete all as specified and directed. |
| 26 | S&F in 20mm steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down complete all as specified and as directed. |
| 27 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in wall / ceilings or laying in floors complete all as specified and as directed. |
| 28 | S&F for Female brass threaded adaptor (FTA/FBTA) for CPVC pipe complete all as specified and as directed. |
| 29 | S&F for brass elbow for 20mm dia CPVC fittings complete all as specified and as directed. |
| 30 | S&F for Brass tee for 20mm dia CPVC pipe complete all as specified and as directed. |
| 31 | S&F for Union for 20mm dia CPVC pipe complete all as specified and as directed. |
| 32 | S&F Rotational moulded poly-ethylene multilayer water storage tanks (cylinderical vertical with closed top) 1000 litres capacity, white in colour hoisted and fixed in position with and including all fittings and fixtures including 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball including dismantling of existing complete all as specified and directed. |
| 33 | S&F in repairs Bib taps, chromium plated fancy type handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore and fixed complete all as specified and as directed. |
| 34 | S&F in repairs Pillar taps, chromium plated fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore and fixed complete all as specified and as directed. |
| 35 | S&F for stop valves (angle cock) ISI marked cast copper alloy, fancy type, chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for PP-R pipes or union suitable for 15mm bore complete all as specified and as directed. |
| 36 | Ditto as per item no 35 above but fix in repair |
| 37 | S&F in repairs 0.80mm thick plain galvanised, mild steel sheeting as in valley gutters, hips, drip and sraight flashing (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 38 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.(ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. complete all as specified and as directed. |
| 39 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 40 | S&F for Anodised aluminium window and ventilator shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws etc. complete all as specified and as directed. |
| 41 | S&F 4.80mm Sheet glass, selected quality and glazing with oil putty in squares exc. 0.5 sqm in each pane complete all as specified and as directed. |
| 42 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 43 | M&L for Anodised aluminium snap grid frame work for false ceiling complete and including 6mm thick Non Asbestos cement plain building boards in false ceiling, fixed or laid/inserted to GI/aluminium framework with screws complete all as specified and as directed. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed. |
| 45 | S&F for Steel work in tubular trusses, Purlin,Post etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 46 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 47 | M&L for rendering 15mm (5mm thick over 10mm thick back coat) thick in Cement mortar (1:4) on external faces of brick/concrete surfaces finished even and smooth without using extra cement mixed with 5% Water proofing compound on external coat of plaster complete all as specified and as directed.Note: Water Proofing compound will be measured and paid separately. |
| 48 | M&L for rendering 15mm thick in Cement mortar (1:6) on otherthan fiar faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified and as directed. |
| 49 | Supply only liquid water proofing compound (ISI Mark) |
| 50 | M&L for applying fair finish of 3mm thick wall putty on walls complete all as specified and as directed. |
| 51 | M&L for preparation of old decorated plastered surfaces of ceiling including cornices, plasters etc and applying one coat of distemper complete all as specified and as directed. |
| 52 | M&L for preparation of old decorated plastered wall surface applying One coat of acrylic distemper on wall complete all as specified and as directed. |
| 53 | M&L for preparation of newly plastered surface and applying two or more coats of acrylic distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms / litre, of approved manufacturer, of required shade and colour complete as per manufacturers specification over alkali resistant priming paint on walls complete all as specified and as directed. |
| 54 | M&L for preparation of newly plastered surface and applying three coats of white wash over one coat of primer on walls complete all as specified and as directed. |
| 55 | M&L for preparation of old painted surface of wall by washing, rubbing down and stopping of painted surface and applying one coat of weather proof acrylic emulsion paint (exterior grade) complete all as specified and as directed. |
| 56 | M&L for applyiing two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces complete all as specified and as directed. |
| 57 | M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 58 | M&L for newly or previously untreated wooden surfaces of any description n.exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 59 | Demolition of cement concrete (unreinforced) of any description in any position not otherwise specifically provided for complete all as specified and as directed. |
| 60 | M&L PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) in coping, benching of manholes etc, and including necessary formwork and including demolition of existing PCC complete all as specified and as directed. |
| 61 | Demolition of cement concrete as in gound floor, pavings n.exc 15cm thickness (below or ground level) complete all as specified and as directed. |
| 62 | M&L for chequered polished tiles (300mm x 300mm x 25mm) size set and pointed in neat grey cement slurry and pointed in coloured cement to match including laying of 20mm thick screed bed in cement mortar (1:4) over and including 75 mm thick cement concrete as in foundation, mass concrete, sub base under fllor (1:4:8) type D-2 (using 40mm graded aggregate) complete all as specifed and as directed. |
| 63 | M&L for 75 mm thick cement concrete as in plinth protection (1:2:4) type B-1 (using 20mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and as directed. |
| 64 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 65 | S&F in repair for Grating doom 150 mm dia of stainless steel complete all as specified and as directed. |
| 66 | M&L for PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and as directed. |
| 67 | Demolition of stone/brick masonry built in cement mortar including all quoins arches pillars etc. complete all as specified and as directed. |
| 68 | M&L for Pre-cast cement concrete Type C1, (1:3:6) (using 20mm graded aggregates) block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and as directed. |
| 69 | M&L for Rendering 12mm thick using CM (1:4) on fair faces of brick work or concrete surfaces and making the surface even and smooth (without using extra cement) with Water proofing as per manufacturer instruction complete all as specified and as directed.Note: Water Proofing compound will be measured and paid separately. |
| 70 | S&F for Cast iron soil, waste and vent pipes 100 mm dia sand cast type in any length with or without ears, with cement joints, laid in trenches or in floors including PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed including packing under and haunching against the sides of pipes complete all as specified and as directed. |
| 71 | Demolition of RCC of any description and any position not otherwise specifically provided for complete all as specified and as directed |
| 72 | M&L for Pre-cast Cement Concrete Type B1, (1:2:4) (using 20mm graded aggregates) setting in CM (1:6) in cover slabs (for manholes etc) complete all as specified and as directed.Note: Reinforcement will be measured and paid for separately. |
| 73 | M&L for Mild steel TMT bars (6 to 8 mm) dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 74 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and as directed. |
| 75 | S&F in repairs Vitreous China wash basin white flat back, size (550 x 400mm) with brackets including cutting for and pinning in ends of brackets or erecting stand and Pillar taps, 15mm dia chromium plated fancy type screwed down high pressurecomplete all as specified and directed. |
| 76 | S&F in repairs plastic water closet seat back, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 77 | S&F in repairs Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 78 | Dismantling of wooden boarding of any description fixed anyu any position with screws complete all as specified and as directed. |
| 79 | S&F for 40 mm thick 2nd class softwood boardning in fascia/eaves board fixed in screws including dismantling of existing complete all as specified and as directed. |
| 80 | M&L for preparation of newly prepared steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, sinck chrome complete all as specified and as directed. |
| 81 | M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400kg of cement per cubic metre, thickness of concrete 25cm or less complete all as specified and as directed.Note : The rate include the cost of formwork up to 200mm thick concrete as required. |
| 82 | Taking down carefully old unserviceable point wiring for one light, socket or power etc including all fittings such as switches sockets, holders, light fittings, fan regulators etc and making good the disturbed surface of wall ceiling complete all as specified and as directed. |
| 83 | M&L for point wiring with 1.5 sqmm (nominal area) single core PVC insulated unshethed FRLS cable, multistranded, copper conductor, in universal color code with & including suitable size of rigid concelled in PVC Conduit and its all accessories complete in wall/roof and including with modular metal box with sheet suaitable for mounting switches, socket, regulator etc and including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size in green color for one light/fan/bell point controlled by one switch complete all as specified and as directed. |
| 84 | All as per item No.83 but one 3 pin 5/6 Amps socket point controlled by one switch on independent board complete all as specified and as directed. |
| 85 | All as per item No.83 but one 3 pin 5/6 Amps socket point controlled by one switch on Same board complete all as specified and as directed. |
| 86 | M&L for point wiring with 2.5 sqmm (nominal area) single core PVC insulated unshethed FRLS cable, multistranded, copper conductor, in universal color code with & iincluding suitable size of rigid concelled in PVC Conduit and its all accessories complete in wall/roof and including with modular metal box and including earth wire of PVC insulated FRLS copper conductor multistranded of 2.5 Sqmm size in green color for one powre point controlled by one switch complete all as specified and as directed. |
| 87 | M&L for switch modular type,single pole one modular 6 Amps 230 volts complete all as specified and as directed. |
| 88 | S&F for socket modular type, single pole two modular 2-in-1, 5 pin, 6 Amps 230 Volt complete all as specified and as directed. |
| 89 | M&L for switch modular type , single pole one moduler 16 Amps 230 volts complete all as specified and as directed. |
| 90 | S&F for socket moduler type, 2-in-1, 5 pin, 6/16 Amps 2 moduler 230 volts complete all as specified and as directed. |
| 91 | M&L for ceiling rose, bakelite, surface type 230/240 volts three terminal PVC/polycarbonate, isolated body complete all as specified and as directed |
| 92 | S & F for SPN DBs 8 Way complete all as specified and as directed. |
| 93 | Taking down old/unservesable ceiling fan/Exhaust fan, sealing cable end dismantaling blades and removing ceiling fan and blades with regulator deposit to MES store complete all as specified and as directed. |
| 94 | S&F for ceiling fans, complete with three blade, down rod, accessories 230 volts, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) including stepped type electronic fan regulator moduler type complete all as specified and as directed. |
| 95 | S&F for LED luminaire (600mmx600mm), 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light cpmplete with driver, holders & LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 96 | S&F for power unit mini modular MCB box 4 way with mini MCB 25 Amps SP with ISI plug top with plastic enclosure for connecting AC's upto 2 ton complete all as specified and as directed. |
| 97 | M&L for sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed copper cable multi standard 1100 volts, FRLS grade with drawn in PVC casing caping and one run of 4 sqmm PVC insulated copper cable as earth continuity conductor drawn in concelled in PVC Conduitcomplete all as specified and as directed. Note : 3 runs of 4 sqmm copper cable and 1 run of concelled in PVC Conduit will be measured as one unit i.e RM |
| 98 | S&F for MCB SPN 40 to 63 amp rating 240V, 10KA, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection and commissioning complete all as specified and as directed. |
| 99 | S&F for MCB SP 6 to 32 amp rating 240V, 10KA, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection and commissioning complete all as specified and as directed. |
| 100 | S&F in LED light fitting 4 feet, 1X20 Watts , 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose complete all as specified and as directed. |
| 101 | S&F in LED light fitting mirror type with high out put diffuser 2 feet, 1X10 Watts , 220 volts, AC decorative type with driver, holderand LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose complete all as specified and as directed. |
| 102 | S&F for Exhaust fan , steel body, double ball bearing, AC single phase, 230 volts of size 300mm sweep with blades and lauvers complete all as specified and as directed. |
| 103 | Excavatioin in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting it out in soft/loose soil including foaming bottom surface to required level for laying pipes complete all as specified and as directed. |
| 104 | Returning, filling in excavated soil including, spreading, levelling, watering, well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 105 | Removing the surplus excavation soil to a distance not exceeding 50m and deposting where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed. |
| 106 | S&F for GI tubing medium grade of size 40 mm dia bore ISI marked laying in trench complete with all accessories such as Tees Union, Bend, Elbow Niple reducer etc. all as required at site for cable protection complete all as specified and as directed. |
| 107 | S&F of DWC (Double corrugated) HDPE pipe ISI marked IS-14390 Part-II, of outer dia 40mm and inner dia 32mm with smooth internal and profiling external surface for non pressure under ground cable including all connected accessories like coupler \\"O\\" ring etc, for protection of cable complete all as specified and as directed. |
| 108 | Supply, Laying & Testing for PVC insulated , PVC sheathed cable galvinized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 2.5 sqmm X 3.00 core , 1100 volts including cable glands, lugs, clamps, saddles,and fasteners etc. as per site requerment complete all as specified and as directed. |
| 109 | M&L and testing for Earthing complete with galvanised steel earth plate elecrode of size (60cm×60cm×6mm) thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size (32 x 6 mm) by means of bolts, nuts, check nuts and washers of washers of galvanised iron or steel all as shown in electrical plate No.5 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing copper sulphate and salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect,protected by 40mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance n.exc. 50 mtr and necessary testing on completion complete all as specified and as directed. |
| 110 | M&L and testing for Earthing complete with galvanized steel earth electrolde (60cmX60cmX6mm) buried dirrectly in ground vertically not less than 2.25mtr below ground level with top edge of earth plate at a depth not less than 1.5mtr below ground level connected to galvanized earth lead wire 4.0 sqmm dia upto 7.5m long by means of bolts, nuts, check nuts and washer etc made of galvanized iron including 50mm bore GI pipe medium grade up 7.5m length all as shown on electrical plate No.3 of SSR Pt I and as specified and indicated and testing on completion including earth work and excavation in any type of soil, PCC chamber, RCC slab with cast iron frame, funnel with water pipe GI 20mm medium grade, wire mesh and lugs complete all as specified and as directed.Note: (i) The unit rate shall be include for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, PCC chamber pit, test point, galvanized earth wire 4.0 sqmm dia from top of earth plate up to 7.5meters above ground level and if GI protection pipe is less than 7.5 meters, no price adjustment shall be made. PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junction etc shall be deemed to be included in the unit rate. (ii) RCC pit thick reinforced with XPM (weighing not less than 4KG/Sqm in liew of cast iron cover.complete all as specified and as directed.(for Watch tower No Two DBs) |
| 111 | Pre-cast Cement Concrete in foundation, filling and mass concrete type (1:3:6), Type-C2 (using 40 mm aggregate grade) (Foundation for boom barrier 2'x2'x2' and 1'x1'x2') complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender