| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying GI pipes and UG cables etc n exc 10 sqmtr on plan and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Maintenance & servicing of existing make and model DG set including tappet cover adjustment & replacement of gasket of capacity upto 30 KVA including necessary replacement of following spares parts if required complete all as specified and directed: (Note: Spares will be measured & paid separately under respective items as supply only) |
| 5 | Supply only of Fuel Filter |
| 6 | Supply only of Lubricant oil filter |
| 7 | Supply only of LLOP sensor |
| 8 | Supply only of Fan belt |
| 9 | Supply only Radiator hose pipe complete set |
| 10 | Supply only Air filter element dry type. |
| 11 | Supply only temperature sensor |
| 12 | Maintenance & servicing of existing make and model DG set including tappaet cover adjustment & replacement of gasket of capacity 40 KVA including necessary replacement of following spares parts if required complete all as specified and directed: (Note: Spares will be measured & paid separately under respective items as supply only) |
| 13 | Supply only of Fuel Filter |
| 14 | Supply only of Lubricant oil filter |
| 15 | Supply only Radiator hose pipe complete set |
| 16 | Supply only Fan belt |
| 17 | Supply only LLOP Sensor |
| 18 | Supply only Air filter element dry type. |
| 19 | Supply only temperature sensor |
| 20 | Materials and labour for taking out old unserviceable engine oil from DG Set sumps, supply & filling new engine oil complete of Make: Servo Super 20W40 of Indian Oil or Equivalent grade of Hindustan Petroleum as approved by GE, complete all as specified and directed. |
| 21 | Materials and labour for topping up of coolant in radiator of DG set of Make: TVS Grilling/Volvo line or equivalent make as approved by GE,complete all as specifoed and as directed. |
| 22 | Materials and labour for dismantling of FIP for overhauling and calibration in authorised workshop including replacement of worn-out rings plungers, damper plate, gasket etc reassembling and testing complete all as specifed and as directed for 30 KVA DG Set. |
| 23 | Materials and labour for dismantling of FIP for overhauling and calibration in authorised workshop including replacement of worn-out rings plungers, damper plate, gasket etc reassembling and testing complete all as specifed and as directed for 40 KVA DG Set. |
| 24 | Repair and Overhauling of self starter including replacement of worn out coil assembly, spring, solenoid switch, carbon brushes, spring etc complete of 12volt any make, type and capacity complete all as specified and as directed all as specified and as directed. |
| 25 | Repair and Overhauling of dynamo/charging alternator including replacement armature winding, brushed, bearing and charging point of any make, type and capacity complete all as specified and as directed. |
| 26 | Materials and labour for cleaning of the fuel tank of DG sets of any KVA capacity after through cleaning with kerosene oil including replacement of following unserviceable spare parts complete all as specified and as directed (Note: Spares will be measured & paid separately under respective items as supply only) |
| 27 | Supply only fuel manual meter complete set |
| 28 | Supply only fuel level sensor. |
| 29 | Materials and labour for dismantling and removing of water pump assembly complete from the engine, repair/overhauling the same by replacing worn out components like bearing, impeller, bushes, oil seal, water seal, gasket etc. re-assembling, refixing and testing complete all as specified and directed for 30 KVA/40 KVA capacityof DG sets. |
| 30 | Supply and fixing in replacement of old unserviceable automatic voltage regulator suitable for 30/40KVA capacity DG set of approved Make & model by the GE, complete all as specified and as directed. |
| 31 | Materials and labour for replacement of old unserviceable existing make and model fly wheel ring including heating for press fitting for engine of DG set of capacity 30KVA to 40 KVA, complete all as specified and as directed. |
| 32 | Materials and labour for replacement of old unserviceable stop solenoid of 30KVA to 40KVA DG Set complete all as specified and as directed. |
| 33 | Dismantaling of radiator of DG Set of 30 KVA capacity and transporting to work shop for servicing/cleaning after dismantling twin tanks, replacement of gasket packing, nuts bolts, washers, descaling with appropriate chemical and welding of copper brazing of damaged fins/tubes and reassembling & refixing in same position after tesing complete all as specified and as directed. |
| 34 | Dismantaling of radiator of DG Set of 40 KVA capacity and transporting to work shop for servicing/cleaning after dismantling twin tanks, replacement of gasket packing, nuts bolts, washers, descaling with appropriate chemical and welding of copper brazing of damaged fins/tubes and reassembling & refixing in same position after tesing complete all as specified and as directed. |
| 35 | Materials and labour for replacement of moulded rectifier unit on existing DG set of capacity 120 Ohms for alternator exciter unit complete all as specified and as directed |
| 36 | Materials and labour for painting of 30 KVA DG sets out side with synthetic enamel paint grey/Blue colour scrubbing preparation for painting and numbering of SM No. /MES No writing with white paint on Engine as well as alternators at different location and size complete as specified and directed. |
| 37 | Materials and labour for painting of 40 KVA DG sets out side with synthetic enamel paint grey/Blue colour scrubbing preparation for painting and numbering of SM No. /MES No writing with white paint on Engine as well as alternators at different location and size complete as specified and directed. |
| 38 | Material and labour for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.Note: The earth resistance value shall be less than 3 Ohm and test report shall be submitted to the department. |
| 39 | Material and labour for pipe earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washers of galvanised iron including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia mediaum grade galvanised steel tube for watering with one and fix with cast iron funnel and wire-mesh, with protection pipe of 32mm dia light grade galvanised steel tubing upto 7.5 meters length for drawing earthlead with filling of bentonite in 600mm dia all around electrode etc, complete including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed.Note: The earth resistance value shall be less than 3 Ohm and test report shall be submitted to the department. |
| 40 | Supply only battery 12Volts 150 AH maintenance free with terminal cable suitable for DG sets complete as specified and directed. |
| 41 | Supply only battery 12Volts 180 AH maintenance free with terminal cable suitable for DG sets complete as specified and directed. |
| 42 | Materials and labour for replacement of on load change over switch 4 pole, 415Volt, of capacity 100Amps, complete as specified and directed. |
| 43 | Materials and labour for overhauling/ Dismantaling, refixing incl servicing of DG set capacity 30KVA to 40 KVA incl replacement of worn out spare part and reassembling it to its original location and testing complete all as specified and directed.(Note: Spares will be measured & paid separately under respective items as supply only) |
| 44 | Supply only complete piston assy |
| 45 | Supply only Cylinder liner |
| 46 | Supply only crank shaft main Bearing complete set |
| 47 | Supply only CR Bearing complete set |
| 48 | Supply only Valve with seat Inlet & Exhaust set |
| 49 | Supply and fixing in repair electronic controller in AMF/control panel of DG set capacity 30/40KVA and making all necessery connection/programming complete to make if fully functional all as directed. |
| 50 | Supply and fixing in repair relay board in AMF/control panel of DG set capacity 30 KVA to 40KVA and making all necessery connection/programming complete to make if fully functional all as directed. |
| 51 | Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure complete all as specified including providing, fixing and connecting following accessories of approved make :- Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos (Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 40 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having double insulation & positive insulation, MCB SPN 20Amps - 03 Nos (ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB) |
| 52 | Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure complete all as specified including providing, fixing and connecting following accessories of approved make :- Incoming :- (i) Aluminium busbar rating 250 Amps rating 4 Nos. (ii) MCCB 160 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 01 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers.(ii)MCB SPN 20 Amps -6 Nos (iii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set |
| 53 | Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure complete all as specified including providing, fixing and connecting following accessories of approved make :- Incoming :- (i) Aluminium busbar rating 400 Amps rating 4 Nos. (ii) MCCB 250 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 160 Amp 4 pole 02 Nos, MCCB 100 Amp 4 pole 02 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set |
| 54 | Supply, installing, testing and commissioning our door type LT panel of suitable size, padestal mounted, CPRI approval factory made totally encloses, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6mm thick MS angle iron and legs of size 0.90mm long. duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6 100 mm thick, 1 Mtr all round the panel board complete with the following items:-INCOMING:- (a) MCCB 4 pole, 415 Volts, 25 KA breaking cap rating 100 amps, adjustable thermal and adjustable magnetic including fixing accessories - 01 N.BUSBAR:-(b) Aluminium busbar suitable for 150 Amp including insulator with nuts & bolts - 04 Nos.OUTGOING (a) MCCB, 415 Volts 40 Amps 4 pole 10 KA rupturing capacity adjustable thermal and fixed magnetic including fixing accessories - 02 Nos (b) MCB, 230 Volts 20 Amps 10 KA SPN rupturing capacity -5 Nos(c) MCB, 230 Volts 10 Amps 10 KA SPN rupturing capacity-5 Nos(d) Led indicator lamp with holder = 03 Nos(e) Digital Amp-meter (0-500) Amps with selector switch - 01 No |
| 55 | Supply & install test point terminal made out of GI strips 32 mm x 6 mm with GI Nuts & bolts mounted on busbar insulators (2Nos) fixed on wall as directed. |
| 56 | Materials and labour for air termination, single pointed aluminium rod 12 mm dia and 300 mm long all as specified and as directed. |
| 57 | Materials and labour aluminium strip 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down unsv complete all as specified and as directed. |
| 58 | Materials and labour for porcelain insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed |
| 59 | Supply and fixing galvanised iron strip 32 x 6 mm buried in ground for interconnection of earthing including taking down unsv complete all as specified and as directed. |
| 60 | Supply and installation of advanced encapsulated compound based CPRI tested maintenance free Pipe pin pipe technology upgraded (zinc and alloy coated) zinc coated (80 to 100) microns with Pure zinc 99.9% and alloy coating 200 to 250 microns Earthing system confirming IS 3043. The outer and inner pipe should be 76.2 mm and 41.9 mm dia or 48.3 mm and 26.4mm 3 meters length zinc coated with additional special pipes being filled up with compact fill crystalline conductive compound the compact film mixture which is machine pressed in the pipe should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity the job includes dealing the pits and refilling the same by Baron Electrode backfill compound. The BFC should be eco friendly it should not contain environmentally hazardous material metal having ROHS certification from NABL accredited lab. The earthpit should be provided with FRP or EPCC earthpit cover for protection and safeguard of terminals in areas where soil condition is bad. Good earth that is black cotton or moisture normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2-4 bags electrode BFC for installation of earth electrode. Resistance of Earthing should be less than 1 ohm. Make: Ashlok /Indelec/Erico/Macmate. |
| 61 | Materials and labour for Glow Sign board of standar size of frame of GI sheet of 2mm thickness at back side, ACP sheet 3mm fitted inside the box and 3D acrylic letters printed on ACP sheet, letters height not exceeding 30 cm, width of letter according to height, with LED lights incl wiring and control system and fixing arrangement for on the pillars/ roof of the pump house/substation including grouting with PCC all as specified and as directed by Engineer-in- charge.Note:-(i) Quotated rates shall be inclusive of 1 year warranty for LED lights and ACP sheet.(ii) Quotated rates shall be inclusive clamps/Fasteners for fixing arrengements.(iii) C-section iron channel and PCC work shall be paid and measured against respective items. |
| 62 | Materials and labour for C cross section iron of size 75 x40 mm including fixing and welding as per direction of Engr-in-Charge |
| 63 | Materials and labour for cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in foundation and bed concrete complete all as specified and as directed |
| 64 | Materials and labour for sign board made up of retro-reflective sheet, letters height not exceeding 10 cm, width of letter according to height writing \\"No Smoking\\"complete all as specified and as directed by Engineer-in- charge. |
| 65 | Materials and labour for sign board made up of retro-reflective sheet, letters height not exceeding 10 cm, width of letter according to height writing \\"No Entry Without permission\\"complete all as specified and as directed by Engineer-in- charge. |
| 66 | Materials and labour for ACP (acrylic sheet) 3 mm thick IS marked fixing of sheet over wall/fencing complete all as specified and as directed by Engineer-in-charge. |
| 67 | Materials and labour for poster made up of vinayl flex (2 mm thick) IS marked as per the matter provided by engineer in charge to be printed on the vinyl sheet and fixed over the surface of ACP sheets by suitable adhesives complete all as specified and as directed by Engineer in charge. |
| 68 | Supply and fixing aluminum frame (1.5x1 feet) L-Shape IS marked for fixing of ACP sheet using suitable size of nuts bolts complete all as specified and as diercetd by Engineer in charge. |
| 69 | First line maitenance and AMC for 25 KLD sewage treatment plant by Sintex for six months.(i) Routine & exepert visit from OEM (Sintex) in every qtr (three times in contract period).(ii) Lab analysis quaterly basis by OEM.(iii) All type of belt ,gear oil and gress will provide by OEM.(iv) OEM will provide 2 breakdown visit.(V)Preventive maintenance of equipment will be done.(vi) OEM will observe the system performance,it is performing as per design or not.(vii) Check the aeration in the aeration chamber is happening proper.(viii) Check the blower are working proper or not.(ix) Check inlet flow and outlet flow.(x) Check electrical panel.(xi) Check sludge level in tank.(xii) Check and recommended in any modification or correction required.(xiii) Provide training to operating staff.(xiii)Draw samples and analyze the parameters like COD,BOD,TSS,Oil& Grease and ph and report will be submit to Engineer-in-charge.All as directed by Enineer-in-charge. Please Enable Macros to View BoQ information |