| 1 | M & L for Carrying out Servicing / Maintenance including B-Check of DG Set of Capacity 320 KVA to 750 KVA of any Make, installed at INS Kalinga / INS Karna / NAD Bheemunipatnam Once in Six months or 300 Hours whichever is earlier by representative / authorised Service Engineer of OEM of the DG Set including inspection, maintenance, changing all types of filters and servicing of DG Sets including Alternator, Non AMF / AMF Panels connected to DG Sets for routine checkup of the engine for the smooth functioning and carrying out the complete as per the Manufacturer’s instructions including replacement of Lub-Oil Filter, Fuel Filter, Bypass Filter, cleaning of Air Filter using Pressure Air, Corrosion Inhibitor, O Ring, Gaskets, Screws etc. and draining out old Engine Oil from Oil Chamber and removing deposited material including applying Grease, CRC in moving parts and draining out water from Radiator Assembly and refilling new after mixing with Coolant including tightening of all Inlet and Outlet connections, taking down Fuel Tank and cleaning and removal of scale and sludge and replacing Minor Items such as Hose Clamp, Screws, Washers, Split Pin, Circlip etc. complete all as specified and as directed. Note: Various Filters, Engine Oil, Coolant etc. will be measured and paid separately as supply only under relevant items of this Schedule. The Spares shall be of make as per existing / OEM and as approved. The rate quoted is deemed to be inclusive of cost of Minor Spares as required and cost of labour required for fixing various spares. Nothing shall be paid extra on this account. |
| 2 | Supply only Air Clean Element Secondary |
| 3 | Supply only Hose Pipe & Flexible Pipe Complete. |
| 4 | Supply only Fan Belt for Water Pump [Make: Fenner / Poly-F / Roulands] |
| 5 | Supply only Fan Belt for Alternator Dynamo [Make: Fenner / Poly-F / Roulands] |
| 6 | Supply only Lub Oil Filter Cartridge |
| 7 | Supply only Diesel Filter Secondary |
| 8 | Supply only Diesel Filter Paper |
| 9 | Supply only Fuel Pre Filter |
| 10 | Supply only Air Clean Element Primary |
| 11 | All as per Serial Item No. 01 above but DG Set of Capacity 100 KVA to 250 KVA complete all as specified and as directed. |
| 12 | Supply only Fuel Pre Filter |
| 13 | Supply only Air Clean Element Primary |
| 14 | Supply only Air Clean Element Secondary |
| 15 | Supply only Fan Belt for Water Pump |
| 16 | Supply only Lub Oil Filter Cartridge |
| 17 | Supply only Diesel Filter Insert |
| 18 | Supply only Diesel Filter Secondary |
| 19 | Supply only Fan Belt for Alternator Dynamo [Make: Fenner / Poly-F / Roulands] |
| 20 | All as per Serial Item No. 01 above but DG Set of Capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 21 | Supply only Lub Oil Filter Cartridge |
| 22 | Supply only Diesel Filter Secondary |
| 23 | Supply only Fuel Pre Filter |
| 24 | Supply only Air Clean Element Primary |
| 25 | Supply only Air Clean Element Secondary |
| 26 | Supply only Hose Pipe & Flexible Pipe Complete. |
| 27 | Supply only Fan Belt for Water Pump |
| 28 | Supply only Fan Belt for Alternator Dynamo [Make: Fenner / Poly-F / Roulands] |
| 29 | Dismantling and opening of Turbo Charger Assembly of DG Set of Capacity 500 KVA to 750 KVA of any Make and repair / replacement of Turbo Charger Kit including all Spares, refixing, testing complete all as specified and as directed. |
| 30 | Dismantling and opening of Turbo Charger Assembly of DG Set of Capacity 250 KVA to 500 KVA of any Make and repair / replacement of Turbo Charger Kit including all Spares, refixing, testing complete all as specified and as directed. |
| 31 | Dismantling and opening of Turbo Charger Assembly of DG Set of Capacity 100 KVA to 250 KVA of any Make and repair / replacement of Turbo Charger Kit including all Spares, refixing, testing complete all as specified and as directed. |
| 32 | Dismantling and opening of Turbo Charger Assembly of DG Set of Capacity 25 KVA to 62.5 KVA of any Make and repair / replacement of Turbo Charger Kit including all Spares, refixing, testing complete all as specified and as directed. |
| 33 | M & L for Repair / Servicing of Radiator Assembly with Intercooler of DG Set of Capacity 320 KVA to 750 KVA of any Make after dismantling and removing Cooling Fans, Guard Plates and lowering the same from Engine after draining out Coolant from Radiator and Scrapping / Removing Sludge / Scale inside tank with Acid including replacement MS Tank [Bottom Portion] at rusted portions by Cutting / Welding / Brazing with 2mm thick Copper Plate including painting, and remounting the same at its original position and replacement of Premixed Coolant as per the Ratio fixed by manufacturer and testing complete all as specified and as directed. |
| 34 | M & L for Repair / Servicing of Radiator Assembly with Intercooler of DG Set of Capacity 100 KVA to 250 KVA of any Make after dismantling and removing Cooling Fans, Guard Plates and lowering the same from Engine after draining out Coolant from Radiator and Scrapping / Removing Sludge / Scale inside tank with Acid including replacement MS Tank [Bottom Portion] at rusted portions by Cutting / Welding / Brazing with 2mm thick Copper Plate including painting, and remounting the same at its original position and replacement of Premixed Coolant as per the Ratio fixed by manufacturer and testing complete all as specified and as directed. |
| 35 | M & L for Repair / Servicing of Radiator Assembly with Intercooler of DG Set of Capacity 25 KVA to 62.5 KVA of any Make after dismantling and removing Cooling Fans, Guard Plates and lowering the same from Engine after draining out Coolant from Radiator and Scrapping / Removing Sludge / Scale inside tank with Acid including replacement MS Tank [Bottom Portion] at rusted portions by Cutting / Welding / Brazing with 2mm thick Copper Plate including painting, and remounting the same at its original position and replacement of Premixed Coolant as per the Ratio fixed by manufacturer and testing complete all as specified and as directed. |
| 36 | M & L for Disconnecting & taking out of existing panel of any description and in any position of DG Set of Capacity 320 KVA to 750 KVA of any Make, Opening of Panel, checking AC/DC Circuits and replacement of Control Wiring as per exiting size Cable, Single Core, Copper Conductor, Flexible, PVC Insulated, Unsheathed Cable suitable up to 1100 Volts confirming to IS – 694, taking out, removing and replacement of unserviceable Parts / Spares / Items as required, reassembling the Panel & fixing the same in position and testing the Panel on Full Load after completion of Repairs complete all as specified and as directed. |
| 37 | M & L for Disconnecting & taking out of existing panel of any description and in any position of DG Set of Capacity 100 KVA to 250 KVA of any Make, Opening of Panel, checking AC/DC Circuits and replacement of Control Wiring as per exiting size Cable, Single Core, Copper Conductor, Flexible, PVC Insulated, Unsheathed Cable suitable up to 1100 Volts confirming to IS – 694, taking out, removing and replacement of unserviceable Parts / Spares / Items as required, reassembling the Panel & fixing the same in position and testing the Panel on Full Load after completion of Repairs complete all as specified and as directed. |
| 38 | M & L for Disconnecting & taking out of existing panel of any description and in any position of DG Set of Capacity 25 KVA to 62.5 KVA of any Make, Opening of Panel, checking AC/DC Circuits and replacement of Control Wiring as per exiting size Cable, Single Core, Copper Conductor, Flexible, PVC Insulated, Unsheathed Cable suitable up to 1100 Volts confirming to IS – 694, taking out, removing and replacement of unserviceable Parts / Spares / Items as required, reassembling the Panel & fixing the same in position and testing the Panel on Full Load after completion of Repairs complete all as specified and as directed. |
| 39 | Dismantling and taking down Alternator Assembly from existing engine and carrying out Servicing / Maintenance of Alternator Unit of DG Set of Capacity 320 KVA to 750 KVA of any Make and comprising of the following works / repairs: [a] Opening of Alternator and cleaning / removing dust from Armature and Field Coil. [b] Cleaning of used / old Lubricated substances Drive / Non Drive End Bearings. [c] Cleaning and checking of AVR Unit. [d] Checking and tightening of Coupling Bolts and replacement of Rubber Inserts. [e] Carrying out Heat Varnishing for Field and Armature Coil and drying properly. [f] Replacement of Bearings as per existing size. [g] Reassembling complete unit and carrying out testing after installation and coupling with DG Set including necessary Alignment, Cable Connections complete all as specified and as directed. [h] Rewinding of Alternator Assembly will be measured and paid separately under respective item of this Schedule / BoQ. |
| 40 | All as per Serial Item No. 14 above but DG Set of Capacity 100 KVA to 250 KVA complete all as specified and as directed. |
| 41 | All as per Serial Item No. 14 above but DG Set of Capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 42 | M & L for Rewinding of Armature with Super Enamelled Copper Conductor of same Gauge, Weight, same Number of turns and with necessary Insulating Material, Varnishing, Backing, Sleeves, Cotton Tape and Heating etc. of DG Set of Capacity 320 KVA to 750 KVA of any Make complete all as specified and as directed. |
| 43 | M & L for Rewinding of Armature with Super Enamelled Copper Conductor of same Gauge, Weight, same Number of turns and with necessary Insulating Material, Varnishing, Backing, Sleeves, Cotton Tape and Heating etc. of DG Set of Capacity 100 KVA to 250 KVA of any Make complete all as specified and as directed. |
| 44 | M & L for Rewinding of Armature with Super Enamelled Copper Conductor of same Gauge, Weight, same Number of turns and with necessary Insulating Material, Varnishing, Backing, Sleeves, Cotton Tape and Heating etc. of DG Set of Capacity 25 KVA to 62.5 KVA of any Make complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 45 | M & L for Rewinding of Armature with Super Enamelled Copper Conductor of same Gauge, Weight, same Number of turns and with necessary Insulating Material, Varnishing, Backing, Sleeves, Cotton Tape and Heating etc. of DG Set of Capacity 25 KVA to 62.5 KVA of any Make complete all as specified and as directed. Please Enable Macros to View BoQ information |