Tender For Replacement Of Contractor Block Landt / Bch, Overload Relay, Sdz5 Timer At Various Pumping Installation In Sector-10, Panchkula. (A/Mtc. Of P.H Services In Sector-1 To 21 And I/A Ph-I And Ii, Panchkula), Panchkula-Haryana
TDR : 56184146
Tender Notice
BOQ
5 Days Left
Panchkula
Haryana
Tender For Replacement Of Contractor Block Landt / Bch, Overload Relay, Sdz5 Timer At Various Pumping Installation In Sector-10, Panchkula. (A/Mtc. Of P.H Services In Sector-1 To 21 And I/A Ph-I And Ii, Panchkula)
Name of Work:- Replacement of Contractor Block LandT / BCH, Overload Relay, SDz5 Timer at various Pumping Installation in Sector-10, Panchkula. (A/Mtc. of P.H Services in Sector-1 to 21 and I/A Ph-I and II, Panchkula)
Sl. No.
Item Description
1
23.22.1.5:- Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
2
20.10.3:- Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 3. 150 mm i/d [Through Rate]
3
20.11.3:- Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in- charge 3. 150 mm i/d [Through Rate]
4
20.114.6:- Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 6. 35 HP Motor [Through Rate]
5
NS Item:- Providing & Fixing of Contractor Block MNX 80 L&T Make as Per Satisfaction of Engineer-in-Charge & attesting on load
6
App. Item:- Providing & Fixing of Overload Relay MN12 CT Operated 60-100 Amp. L&T make satisfaction of Engineer-in-Charge & attesting on load.
7
NS Item:- Providing & Fixing of Copper wire multistand 35 sq mm
8
NS Item:- Providing and Fixing of Single phase preventor LandT/Minilac make as per satisfaction of Engineer-in- charge and attesting on load to the entire satisfaction of EIC.
9
NS Item:- PF of Electrical CT Meter Box size 43” length 16” width and 8” depth (heavy duty) shockproof and rustproof cable entry from bottom and or side 100% waterproof pole mounting arrangement tamper proof mtc. free fire retardant class FV-0 as per IS:11731 Part-II or V-0 as per UL-94 High heat distoration (200C as per IS:10192) with angle fasner nut bolt and site fitting complete in all respect to the entire satisfaction of EIC.
10
NS Item:- PF of Current Transformer (CT) 100/5 energy meter ratio 100/5 frequent 50 Hz burden 5 VA 0.5 accuracy make Concard / Vishal / Jai Durga / Secure including testing fees etc. complete in all respect to the entire satisfaction of EIC.
11
NS Item:- Providing and Fixing of SPPR type SDz5 Timer 415 volt make LandT complete in all respect to the entire satisfaction of EIC and attesting on load. Please Enable Macros to View BoQ information