| 1 | PART-A |
| 2 | (3.1.6)Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). |
| 3 | (B) M-15 grade N.Mix ( 1 cement : 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size.) (3.1.2) |
| 4 | (5.8.3) Half brick masonry in Superstructure, using bricks of designation 75 in CM 1:6 upto third storey. |
| 5 | 5.2.2Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 6 | (3.8)Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification . |
| 7 | (8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :comercial veneer both side 30 mm thick . |
| 8 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:(A) 20mm thick. (12.3.2) |
| 9 | (B) 12 mm thick (12.3.3) |
| 10 | (12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 11 | (12.22.1)Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 12 | (12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 13 | (12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 14 | 7.22.3P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm |
| 15 | Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. (15.28.1) |
| 16 | R/6.3 (iii) (a)P & l of Interlocking M-30 grade concrete Block pavements having thickness 80 mm as per drawings & MoRD Specification Clause 1504 with M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks. Category 'A' Dentated units to key into each other on all four faces zigzag shape as per IRC: SP:63-2004. |
| 17 | 13.29Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect. |
| 18 | 2.26.3/S-2P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 ltr capacity |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size. (2.38.2) |
| 20 | (B) 25 mm nominal size (2.38.3) |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).(A) 20mm nominal size (2.39.2) |
| 22 | (B) 25 mm nominal size (2.39.3) |
| 23 | 2.7.3 /S-2P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:(A) C.P. brass bib cock 15mm nominal bore. |
| 24 | (2.11.1)P&F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete:Brass wt. not less than 300 grm, 15mm. |
| 25 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :(a)Gun-metal 15mm nominal bore.(2.15.1) |
| 26 | (B)Gun-metal 25mm nominal bore.(2.15.3) |
| 27 | (2.12.1)P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 28 | P & F 15 mm. Dia Connection Pipe of approved quality/make : (a) PVC pipe with C.P. Brass nuts upto length, 300mm(2.13.1) |
| 29 | (3.16.2 , 3.16.3)P & F rigid PVC Pipe (IS : 4985 mark) class II / (4 Kg. / Cm2 .) approved quality / make including joining the pipe with solvent cement rubber ring and lubricant.(a)75 mm dia |
| 30 | (b)110 mm dia |
| 31 | P & F rigid pvc pipe fittings (IS : 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant :110 mm dia.(A) Bend 45˚ (3.17.8.ii) |
| 32 | (B) Bend 87.5˚ .(3.17.9.ii) |
| 33 | (C) Vent Cowel (3.17.12.ii) |
| 34 | PART- B (Item Rate Basis) |
| 35 | E/W in filling of excavated earth except black cotton soil with watering & compaction of spreaded earth in 15-30cm layers levelled & neatly dressed as per requirement of site & direction of E/I, work includes cost of earth with taxes, loading, unloading, transportation, labour, water & T&P etc. complete with all lead & lift. |
| 36 | Supply and spreading of crusher dust free of organic matter including stacking spreading and laying in yard as per standard specification including all lead and lift, Transportation, labour, loading unloading, T&P required for spreading of crusher dust work as per direction of Engineer in Charge including dressing ground upto 15cm depth. |
| 37 | S, S & S of graded crusher brocken hard stone aggregate free from organic matter including stacking & spreading in yard / trenches as per the standard specification of size 40mm to 63mm incl. all lead & lift, transportation, labour, loading, unloading & require for graveling work as per direction if Engineer in charge incl. dressing & levelling. Please Enable Macros to View BoQ information |