| 1 | fo|qr forj.k [k.M&cqyUn'kgj¼xzkeh.k½] ds vUrxZr iw.kZ tek ;kstuk en esa fuos'k fe=@>ViV iksVZy ls izkIr vkosnukas ds lkis{k ykbZu cukus@f'k¶V o vU; laca/kh dk;ZA |
| 2 | DESCRIPTION OF WORK/ITEM (S) |
| 3 | Safe carriage of Pole, from store center to site store with loading & unloading at both ends respectively distance within- 0 to 80 Kms. |
| 4 | 8.5/9 mtr. long PCC/ST Pole |
| 5 | 11/13 mtr. long PCC/ST Pole |
| 6 | Loading, Safe carriage & unloading of heavy stock material , Disc Insulator, Pin Insulator, ETC from store center to site store with proper stacking of material, distance within-150Kms. |
| 7 | Loading, Safe carriage & unloading of LT/HT Conductor, T/F, etc from store center to site store with proper stacking of material, distance within-80 Kms. |
| 8 | 11 KV XLPE Cable 3x70 Sq mm |
| 9 | 11 KV XLPE Cable 3x120/3x185 Sq mm |
| 10 | 11&33KV XLPE Cable 3x300 Sq mm |
| 11 | LT Armoured Cable 2x6/4x16 Sq mm |
| 12 | 3x120+1x95+1x35 Sq mm AB Cable |
| 13 | 3x95+1x50+1x16 Sq mm AB Cable |
| 14 | 3x50+1x35+1x16 Sq mm AB Cable |
| 15 | 1x25+1x16 Sq mm AB Cable |
| 16 | ACSR Dog Conductor |
| 17 | ACSR Weasel/Rabbit Conductor |
| 18 | T/F 10 KVA 11/0.4 KV |
| 19 | T/F 25 KVA 11/0.4 KV |
| 20 | T/F 63 KVA 11/0.4 KV |
| 21 | T/F 100 KVA 11/0.4 KV |
| 22 | CT/PT Unit Various Ratio |
| 23 | Meter Cubcle Various Ratio |
| 24 | Erection of Complete Single 8.5/9/11/13 mtr long STP/PCC Pole With All LT & HT Accessories As 11 & 33 KV X-Arm With Clamp, 11 & 33 KV Pin & Disc Insulator With Fitting,T-Off Channel, Earth Rod, 11 & 33 KV F-Clamp, Stay Set, LT Shakle Insulator, Eathing Suspention/Ded & Clamp With J-I Hook, Number/Denger Board, Barbed Wire, Jumphering as per RESPO Mannual |
| 25 | 8.5/9/11/13 mtr long STP/PCC Pole |
| 26 | Erection of Complete 8.5/9/11/13 mtr long STP/PCC Double/Section Pole With Top/Dropper/T-Off/TF Base Angle/Bracing Angle,Stay Set, 11 & 33 KV Pin & Disc Insulator With Fitting, Earth Rod, Fuse Set, LT Fuse Unit With Box & Wire, Lead With Lug, Number/Denger Board, Barbed Wire,6\\" G.I Pipe, Jumphering as per RESPO Mannual |
| 27 | 8.5/9/11/13 mtr long STP/PCC Pole |
| 28 | Excavation of For grouting of Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone Pad etc. as per actual site requirement |
| 29 | 8.5/9/11/13 mtr long STP/PCC Pole |
| 30 | Stay Set Grouting |
| 31 | Gaurding of 11 Kv line |
| 32 | Installation Of 10-100 KVA Distribution Tranformer With By Crane/Hydra & Laying sagging stringing and binding and jumpering etc of following ACSR Conductor/wisel/Rabit/ABC all size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work. |
| 33 | 11 KV XLPE Cable 3x70 Sq mm Laying by Cut Open Method With Sand & Bricks As Per RESPO Mannual |
| 34 | 11 KV XLPE Cable 3x120/3x185 Sq mm Laying by Cut Open Method With Sand & Bricks As Per RESPO Mannual |
| 35 | 11&33KV XLPE Cable 3x300 Sq mm Laying by Cut Open Method With Sand & Bricks As Per RESPO Mannual |
| 36 | 11&33KV XLPE Cable 3x300 Sq mm Laying by HDPE Pipe (Trunchless) As Per RESPO Mannual |
| 37 | LT Armoured Cable 2x6/4x16 Sq mm |
| 38 | 3x120+1x95+1x35 Sq mm AB Cable |
| 39 | 3x95+1x50+1x16 Sq mm AB Cable |
| 40 | 3x50+1x35+1x16 Sq mm AB Cable |
| 41 | 1x25+1x16 Sq mm AB Cable |
| 42 | ACSR Dog Conductor |
| 43 | ACSR Weasel/Rabbit Conductor |
| 44 | T/F 10 KVA 11/0.4 KV |
| 45 | T/F 25 KVA 11/0.4 KV |
| 46 | T/F 63 KVA 11/0.4 KV |
| 47 | T/F 100 KVA 11/0.4 KV |
| 48 | CT/PT Unit Various Ratio |
| 49 | Dismantling and receive back old T/F 10-100 KVA from site to esc store. |
| 50 | Dismantling and receive back old all Type pole/Conducter/MS Iron From Different Sites & Deposit In Store |
| 51 | The follwing material will be providing & Fixing by the contractor . |
| 52 | Making/Filling of 11 & 33 KV Cable Jointing Kit I/O & O/D AS per RESPO mannual |
| 53 | Cutting & Drilling Of MS T-Off/Droppe/Top Channel/Bracing & TF Base Angle |
| 54 | Providing & Fixing of Stone Pad 3x300x75 as per RESPO mannual |
| 55 | Providing of LT Shakle Insulator as per RESPO mannual |
| 56 | Providing MS Nut & Bolt Off Size as per RESPO mannual |
| 57 | Providing Holding Clamp With Nut & Bol For Top/TPMO/X-Arm as per RESPO mannual |
| 58 | Providing of Danger Board With Barbed Wire & Jumpher as per RESPO mannual |
| 59 | Providing of Suspention Clamp With I Hook as per RESPO mannual |
| 60 | Providing Of Ded End Clamp With J Hook as per RESPO mannual |
| 61 | Providing & Fixing of LT PRC Off Size as per RESPO mannual |
| 62 | Providing & Fixing of Chemical Earthing With All Required Material As Per Site & as per RESPO mannual |
| 63 | Providing of AL Lug Long Berrel Off Size as per RESPO mannual |
| 64 | Providing of 11 & 33 KV F-Clamp With Nut & Bolt as per RESPO mannual |
| 65 | Providing of 6\\" G.I Pipe as per RESPO mannual |
| 66 | Providing of HDPE Pipe as per RESPO mannual Please Enable Macros to View BoQ information |