| 1 | Surface excavation n.exc 40cm deep and averaging 15cm deep and getting out in soft/loose soil, , complete all as specified and as directed. |
| 2 | Excavation in trenches in any type of soil, n exc 1.5 M wide and n exc 1.5 M deep for foundation, etc or for shafts, wells, manholes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, , complete all as specified and as directed. |
| 3 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, , complete all as specified and as directed. |
| 4 | Removing of excavated soil not exceeding 50m and depositing where directed at a level not exc 1.5 M above the starting point, , complete all as specified and as directed. |
| 5 | M&L Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate), in foundation, filling and mass concrete, , complete all as specified and as directed. |
| 6 | M & L pre-cast cement concrete block masonry Type C-1, 1:3:6 (20mm graded aggregate) with solid blocks, exc 10cm in width and seting in cement Mortar 1:6, , complete all as specified and as directed. |
| 7 | M & L Rendering 10 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, , complete all as specified and as directed. |
| 8 | M & L Rendering 15 mm thick in cement and sand mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing with using integral waterproofing compound @ 3% by weight of cement including finishing the surface even and smooth without using extra cement , complete all as specified and as directed. (Note - W P C shall be measured and paid separately). |
| 9 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint , complete all as specified and as directed.. |
| 10 | Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper , complete all as specified and as directed.. |
| 11 | M & L for Machine cut kota stone slab flooring 18-20mm thick (mirror polished) including bee wax polishing on surfaces of any description width or girth including cleaning and preparing the surface , complete all as specified and as directed. |
| 12 | M&L for Kota stone slab 20-25 mm thick in riser or steps, skirting, dado and pillar laid over cement screed and jointed, completed all as specified and as directed |
| 13 | S & F Roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and as directed. |
| 14 | M & L Preparation of new steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint on Steel sheeting as in roofing, complete all as specified and as directed. |
| 15 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc, complete all as specified and as directed. |
| 16 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 17 | S&F mild steel framed work such as grills (Ventilators for secuerity post) & frame work of water taks or posts of FE 290 Gde E-165, complete all as specified and as directed. |
| 18 | S&F Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded, complete all as specified and as directed. |
| 19 | Use & waste of formwork to rough finished surfaces of concrete, form work to sides of plinth beam, footings, bases of columns etc, complete all as specified and as directed. |
| 20 | M&L for RCC Nominal mix type B1 1:2:4 using 20mm graded aggregate as in fdn, footing, plinth beam, bases for columns etc, complete all as specified and as directed. |
| 21 | Use & waste of formwork to square or rectangle shape and fair finished surfaces of concrete, to sides of pillars, post , struts etc, complete all as specified and as directed. |
| 22 | M&L for RCC Nominal mix type B1 1:2:4 using 20mm graded aggregate as in columns etc, complete all as specified and as directed. |
| 23 | Use & waste of Formwork finished fair to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc etc, complete all as specified and as directed. |
| 24 | M &L RCC Nominal mix type B1 1:2:4(20mm grade aggregate in beam bressummers, lintels over 1.5m span etc, complete all as specified and as directed. |
| 25 | Formwork to soffits of fair finished suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (Horizontal or sloping) etc , complete all as specified and as directed. |
| 26 | M&L for reinforced cement concrete type B1 1:2:4 ( 20mm graded stone aggregate as in slabs supported on walls, beams and columns, complete all as specified and as directed. |
| 27 | S & F Mild steel TMT bars 10 mm dia and over, quality conforming to Grade 415 MPA cut to length , bent to shape required incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia. |
| 28 | All as per item above but 5mm dia and above including 10mm dia in stirrups, complete all as specified and as directed. |
| 29 | M & L 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement , complete all as specified and as directed.. |
| 30 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 31 | M & L PCC 1:3:6 type C - 2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate).complete all as specifed and directed. |
| 32 | Walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in CM 1:4 , complete all as specified and as directed.. |
| 33 | M&L for PCC 1:2:4 type B-1 (Using 20 mm graded crushed stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles , complete all as specified and as directed.. |
| 34 | M&L for flush pointing to random rubble masonary, uncoursed or brought upto courses in CM 1:3 , complete all as specified and as directed.. |
| 35 | Extra over stone walling for hammer dressing to face of stones and dressing of face beds and joints, as specified of random rubble walling uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20 mm on granite or trap stone , complete all as specified and as directed.. |
| 36 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc , complete all as specified and as directed.. |
| 37 | Add or deduct for each 25 mm girth or part there of over or under 30cm ditto , complete all as specified and as directed.. |
| 38 | M&L for reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like , complete all as specified and as directed.. |
| 39 | Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) , complete all as specified and as directed.. |
| 40 | M&L for point wiring using approved colour coding as per IS (For phase and neural), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including heavy duty PVC concealed conduit with fittings ISI marked, terminated in junction box incl 1.5 Sqmm and connected to earth dolly including fixing of 1. 2 mm thick MS sunk terminal box 60 mm deep (minimum size 100 x 100 mm square) suitably flushed to wall with 3 mm thick plastic laminated/ebonite sheet cover fixed with brass screws and cup washers incding making good the disturbed surfaces, complete all as specified and as directed. |
| 41 | a) One light point controlled by one switch/one fan point/one bell or buzzer controlled by one switch & fan regulator, complete all as specified and as directed. |
| 42 | (b) One switch socket outlet 5 Amps on same boardwith other switches. |
| 43 | M&L Point wiring complete with FRLS 1100 Volts grade, 2.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 20 mm medium grade ISl marked conduit concealed in wall/ceiling all accessories such as bends, elbow, reducers, junction boxes /MS boxes duly painted /PVC box factory made rectangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 2.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following :Note: Contractor must do internal wiring with cheasel cutting in wall/ceiling and fixed conduit and repair surface with plaster 15MM in wall/ceiling and make surface good as it is. |
| 44 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 45 | S&F switch piano Flush type, single pole16 amp 240 volts, complete all as specified and as directed. |
| 46 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed. |
| 47 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 48 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 49 | S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 50 | M&L for sheet metal enclosure for DBs when MCB to be used single phase 240 volts, double door 4 way with 200 Amps rated bus bar, complete all as specified and as directed. |
| 51 | S & F MCB SP 6 to 32 Amps, 240 Volts, B Curve, complete all as specified and as directed. |
| 52 | S & F MCB, SPN 40 Amps 240 Volts C Curve, complete all as specified and as directed. |
| 53 | S&F LED Lamp 10 W complete all as specified and as directed |
| 54 | S& F LED light fitting 1x10 bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 55 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling, complete all as specified and as directed. |
| 56 | M/L for Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 15 mm bore, medium grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm reinforced with 8 mm dia TMT bars 100 C to C including one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing medium grade for watering ,charcoal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I. |
| 57 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core |
| 58 | Excavation in trenches, n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of XLPE UG cables and getting out in soft/ loose soil, complete all as specified and as directed. |
| 59 | Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed. (Note the punned down thickness shall only be measeured ) |
| 60 | Supply and laying sub class 'B' bricks laid across the cable for cable protection, complete all as specified and as directed. |
| 61 | S&F GI light grade tube of size 25 mm dia for laid in trenches/ wall for protection of cable, complete all as specified and as directed. Please Enable Macros to View BoQ information |