Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56180041

Tender For Providing Of Deficient Married Accn At Af Stn Dinjan

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
28.50 Crore
Estimated cost
Bid Submission
10 Sep 2026
13 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Deficient Married Accn At Af Stn Dinjan

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Jul-2026 Corrigendum_1 Date 06-Aug-2026
2 23-Jul-2026 Corrigendum_1 Date 06-Aug-2026
3 28-Jul-2026 Corrigendum_2 Date 13-Aug-2026
4 19-Aug-2026 Corrigendum_5 Date 03-Sep-2026
5 04-Aug-2026 Corrigendum_3 Date 20-Aug-2026
6 11-Aug-2026 Corrigendum_4 Date 27-Aug-2026
7 27-Aug-2026 Corrigendum_6 Date 10-Sep-2026

BOQ

Name of Work:- PROVN OF DEFICIENT MARRIED ACCN AT AF STN DINJAN
Sl. No. Item Description
1BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVN OF DEFICIENT MARRIED ACCN AT AF STN DINJAN Contract No: CE(AF)SZ/DIN/ OF 2026-2027 File No: 88683/DIN/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:-
3SCHEDULE \\"A\\" PART- II (SITE CLEARANCE AND DEVELOPMENT) Details of prepriced Schedule is given in tender documents
4SCHEDULE \\"A\\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents.
5SCHEDULE \\"A\\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents.
6SCHEDULE \\"A\\" PART- V (ROADS/PATH/CULVERT)Details of prepriced Schedule is given in tender documents.
7SCHEDULE \\"A\\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents
8SCHEDULE \\"A\\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents
9SCHEDULE \\"A\\" PART- VIII (SECURITY FENCING AND GATE )Details of prepriced Schedule is given in tender documents
10SCHEDULE \\"A\\" PART- IX(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents.
11SCHEDULE \\"A\\" PART- X(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents.
12SCHEDULE \\"A\\" PART- XI(HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents.
13SCHEDULE \\"A\\" PART- XII(DEMOLITION)Details of prepriced Schedule is given in tender documents.
14SCHEDULE \\"A\\" PART -XIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only.
15INTERNAL ELECTRIFICATIONS&F LED rechargeable emergency inverter bulb 10/12 Watt complete all as directed and specified.
16Supply and Fixing LED decorative light fitting 10W, 220 V, AC including LED light connecting up wih three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
17S&F TV socket single moudle, polycarbonate type complete with box complete all as specified and as directed.
18S&F wall mounted fan plastic body, single phase, 230 volts, 50 Hz of size 400 mm sweep, heavy duty type with flexible three core copper conductor cable of suitable size and 5 Amp plug complete all as specified and directed
19M&L, testing,installation,commissiong of Kitchen Exhaust System (Chimney), Filter Less and Dry Heat Clean Technology / Matt Black Finish, Hassle free and dry Heat Auto Clean Technology, Thermostatic Touch Control Panel with 3 speed Gesture Motion, including Matt Black Finish, Black Metal Oil Collector, Motor with Copper Winding, Black Glass Clad Hood with LED Insignia, Front Panel with Black Glass, Energy Saving LED Light,Metal Blower+ Metal Housing,Designed Air Flow (max),: 1250Nm3/h, Noise level :58 dBA (max), 5 years Warranty, Size:90Cm complete all Civil work for fixing system,including fixing of Duct and complete Electrical wiring upto the socket point as required for system running complete all as specified and directed.
20Supply and fix concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 6 way IP 43 suitable for MCCB of 63 Amps, 4 Pole, 25 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and directed.Note:- (i) MCCB/ MCBs shall be measured and paid saperately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate.
21Supply and fix concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 4 way IP 43 suitable for MCCB of 63 Amps, 4 Pole, 25 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and directed.Note:- (i) MCCB/ MCBs shall be measured and paid saperately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate.
22Supply and fix MCB 230 Volts, 50 Hz, SPN, 16 Amps, 10 KA with \\"C\\" curve complete all as specified and directed.
23Supply and fix MCB 230 Volts, 50 Hz, Single Pole, 63 Amps, 10 KA with \\"C\\" curve complete all as specified and directed.
24Supply and fix MCB 230 Volts, 50 Hz, SPN, 63 Amps, 10 KA with \\"B\\" curve complete all as specified and directed.
25Supply and fix MCB 230 Volts, 50 Hz, SPN, 32 Amps, 10 KA with \\"B\\" curve complete all as specified and directed.
26Supply and fix MCB 230 Volts, 50 Hz, Single Pole, 63 Amps, 10 KA with \\"B\\" curve complete all as specified and directed.
27M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick electrode and 4 mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
28INTERNAL WATER SUPPLYS&F 15 mm bore two way Bib tap long body cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down, screwed for iron pipe or brass ferrule for 15 mm bore of pipe complete all as specified and as directed.
29SEWAGE DISPOSALM&L for RCC Septic tank conventional designed to carry sewage sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Designed mix in walls, base slab, Baffle walls and roof slab including beams etc with Vent shaft manhole openings with cover connection etc, complete with effective depth of 1.5m and over all depth 3 mtr of 50 users. including RFR, removal complete all as specified and directed.
30M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of Size 2.4 mtr x 6.0 mtr effective depth, complete all as specified and as directed.
31EXTERNAL WATER SUPPLYSupply and laying 90mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
32Supply and laying 63mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
33Supply and laying 32mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
34Supply and fix Valves, Sluice, flanged of class 1.0 PN, 80 mm (3”)dia complete including all fittings. complete all as specified and directed.
35Supply and fix Reflux valve/NRV flanged type of PN-1.6, 50 mm (2”)dia complete including all fittings complete all as specified and directed.
36Supply and fixing PP-R Gate Valves (Brass Insert) of 32 mm bore of outer dia. complete including all fittings, complete all as specified and directed.
37Supply and fixing PP-R Gate Valves (Brass Insert) of 63 mm bore of outer dia. complete including all fittings, complete all as specified and directed.
38Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 160/110 mm dia. complete all as specified and directed
39Cutting or screwing existing steel tubing for alteration or additions suitable size for 50 mm dia complete all as specified and directed
40Material and Labour for constrution of valves pit chamber of size (900 mm x 900 mm x 900 mm, internal ) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick , 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement motar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement MS frame out of 40 x 40x 5 mm thick angle iron including paintaing of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer finishing coat including necessary excavation in any type of soil, returing filling in and removal of surplus soil to adistance not exceeding 50 mtrs all as specified and including demolition / dismantling of existing craked valve chamber complete all as specifeid and directed.
41Supply, install and testing of open well Submersible pump set , of capacity 02 HP (1.5 KW), head 20-25 mtr, electric driven 415 V, TP with suction side 50mm and delivery side 40 mm complete all as specified and directed.
42Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
43S&F and testing and commissioning pressed moulded thermosetting GRP water tank (IS-14399) of size 5mX4X2m (H) of 30000 ltrs capacity including manhole panels on the roof with proper locking arrangements fixed at any position installated on PCC/RCC foundation with required no of holes on plates and other required joining materials i.e lead wire/wool,putty/compound nut bolt and washers etc to make the jointing portion absloutely leak proof complete all as specified and directed.Note :- (i) Work shall be carried out in safety norms and all safety should be provided by the contractor and no extra claim shall be admissable at later stage.(ii) Contractor shall submit the design of GRP tank to CWE for their approval.
44EXTERNAL ELECTRIFICATIONSupply, install, testing and commissioning of CPRI approved LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54 suitable for outdoor use double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet and indoor structure made out of 2.0 mm thick CRCA steel sheet of minimum size ( 1.0x1.0 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- INCOMER :-(a) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 25 KA of 100 Amps with Fixed thermal and Fixed magnetic setting- 01 NoBUSBAR :-(i) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 NosINDICATING DEVICES :-(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos(b) Supply and fixing Digital Ampere Meter of 0-125 A, 3 phase, class 1 with selector switch including CT having CTR 100/5 - 01 No(c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No
45Serial Item No. 43.00 (Contd....)Outgoing :-(a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 63 Amps with Fixed thermal and Fixed magnetic setting- 02 No (01 Outgoing for two Building+01 Spare)
46Supply, install, testing and commissioning of CPRI approved LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54 suitable for outdoor use double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet and indoor structure made out of 2.0 mm thick CRCA steel sheet of minimum size ( 1.2x1.2 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- INCOMER :-(a) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 25 KA of 200 Amps with Fixed thermal and Fixed magnetic setting- 01 NoBUSBAR :-(i) Aluminium bus bar 300 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 NosINDICATING DEVICES :-(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos(b ) Supply and fixing Digital Ampere Meter of 0-300 A, 3 phase, class 1 with selector switch including CT having CTR 200/5 - 01 No(c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No
47Serial Item No. 45.00 (Contd....)Outgoing :-(a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 40 Amps with Fixed thermal and Fixed magnetic setting- 06 No (b) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 32 Amps with Fixed thermal and Fixed magnetic setting- 01 No(c) Supply and fixing MCCB 2 pole 230 Volts with of breaking capacity of 10 KA of 10 Amps with Fixed thermal and Fixed magnetic setting- 02 No(d) Supply and fixing Astronomical Timer switch along with contractor 3P 32 Amps, 415V, 50 Hz for street light controlling
48Supply, install, testing and commissioning of CPRI approved LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54 suitable for outdoor use double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet and indoor structure made out of 2.0 mm thick CRCA steel sheet of minimum size ( 1.0x1.0 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- INCOMER :-(a) Supply and fixing Changeover of capacity 4 Pole,415 Volts of capacity 63 Amps open execution type -01 Nos(b) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 25 KA of 32 Amps with Fixed thermal and Fixed magnetic setting- 01 NoBUSBAR :-(i) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 NosINDICATING DEVICES :-(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos(b ) Supply and fixing Digital Ampere Meter of 0-300 A, 3 phase, class 1 with selector switch including CT having CTR 63/5 - 01 No(c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No
49Serial Item No. 47.00 (Contd....)Outgoing :-(a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 16 Amps with Fixed thermal and Fixed magnetic setting- 03 No(b) DOL starter suitable for 02 HP pumpset 02 No including contactor of suitable size and connected accessories complete to run the submersible pumpset
50Supply and laying flat copper three Core 06 sqmm PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors complete all as specified and as directed.
51M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
52Supply and fix LED street light 45 W with minimum lumen of 4500Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole including with GI bracket 1.5 meter long bend to shape of dia 40mm GI medium grade pipe with MS clamp complete all as specified and as directed.
53Supply and fix cable junction boxes IP 66 \\"halogen free and weather proof\\" for outdoor installation (with metric knockouts for cable entry) of minimum size 225 x 295 x 125 mm for 16/25 sq.mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 kA, 10 Amps and including minium 100 Amps connector with nuts, bolts & washers, complete all as specified and as directed.
54Supply and fixing PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, three core of copper conductor for connection of street light fittings on pole / wall / pillar from junction box including termination clip etc complete in all respect including through GI tubing of size 20mm dia or all as specified or directed.
55Supply and fixing of all-in-one solar street light of 30watt including monocrystaline solar panel of 60Wp, new age lithium ferro phospate battery of capacity 12.8V/3.6Ah, silicon encapsulated high effiicency MPPT charge controller, aluminium housing for battery box and mounting bracket mounted on 5mtr GI pole of medium grade complete including errection and foundation work all as specified and directed.
56Design, Installation,Testing, Commissioning, Integrate and maintain the Advance Metering infrastructure (AMI) of smart meters of same/different makes to ensure interchangeability at later date as per BIS16444 with specific CM/L number using communication technology including GPRS/RF/Hybrid (RF + cellular) as per CEA/TRAI regulations including integration of different devices of different makes/ equipment/software as per functional requirements in order to achieve overall economy in operation and maintenance . The AMI software and associated infrastructure should be capable of handling the quantity of meters of different makes as per BIS:16444 as per Sl Item No 56.00 and 57.00, including training and knowledge transfer, all expenditure incl periodic charges of telecom operator from installation till DLP of 2 years (which will include charges of hosting on GCC Server, recharge and any other misc charges required to keep the system functional), obtaining audit of software for smart meters by CERT-India empanelled firms / CERT Auditor of Armed Forces, comprising all as specified having minimum parameters / specification as under:-Note:(i) The design of AMI Infrastructure is to be approved by the GE before commencement of work. Necessary DBR (Design Basis Report) is to be submitted to the department by the contractor and to be approved by the GE. It should be ensured that the design is most economical from maintenance as well as overall project point of view. AMI infrastructure provider/ contractor shall demonstrate complete functioning including interoperability of AMI infrastructure including Smart Meter in presence of rep of GE before approval of DBR by GE.
57Supply, Set up and Tuning of Smart RF/Cellular/Hybrid (RF+Cellular) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards including inbuilt Radio Frequency communication facility with self healing mesh network/ GPRS(Cellular) Network facility/ Hybrid Network facility as per design with default and on demand display,anti-tamper features, Microprocessor and LED/LCD based circuitry including SMC Meter Box of suitable size for Single Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency. Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Note: This will also include Cost of Planning / Setup/Tuning of RF/GPRS/Hybrid (RF+GPRS) Communication infrastructure including the Network Management and Head End System(HES) for complete Automatic Metering Infrastructure (AMI) solution and the same shall be capable of meter data acquisition at user selected period, mantain time synchronism with smart energy meter and mantain communication device status and will provide visual interface to view the data/events
58Supply, Set up and Tuning of Smart RF/Cellular/Hybrid (RF+Cellular) Three Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards including inbuilt Radio Frequency communication facility with self healing mesh network/ GPRS(Cellular) Network facility/ Hybrid Network facility as per design with default and on demand display,anti-tamper features, Microprocessor and LED/LCD based circuitry including SMC Meter Box of suitable size for Three Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency. Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Note: This will also include Cost of Planning / Setup/Tuning of RF/GPRS/Hybrid (RF+GPRS) Communication infrastructure including the Network Management and Head End System(HES) for complete Automatic Metering Infrastructure (AMI) solution and the same shall be capable of meter data acquisition at user selected period, mantain time synchronism with smart energy meter and mantain communication device status and will provide visual interface to view the data/events
59Notes for Srl item No. 56.00 & 57.00 :-(a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES and the cost of the same is deemed to be included in the quoted rate for Smart Energy Meters.(b) It would be possible to run the meter in both prepaid and postpaid mode(c) Meter shall carry minimum 10 years warranty.(d) The OEM would need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. The OEM should provide complete support to MES to be able to integrate the AMI infrastructure with any IS 16444 compliant meters and connected accessories such as RF/GPRS/Hybrid Infrastructure including supporting software without any extra cost to the department. (e) During Defect liablity period of 2 years post completion of work of AMI infrastructure the contractor has to replace the Smart Meter irrespctive of the extent of fault in defective smart meter, if any in subject work.
60Supply and Setup of Meter Data Management (MDM) system including supply and configuration of the Web based Software with following modules:(i) Meter Data Management ModuleThe meter data management module would be deemed for collecting the data from the meter and sending to DCU/server directly and vice versa based on type of communication (RF or Cellular/Hybrid), make the data available in bidirectional mode to support the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise KVA allocation/tripping, tariff regulations, software customisations etc all as directed by the Engr-in-Charge with the following features:(a) 15 min instantenous data from all the meters for minimum six parameters- Cumulative Energy, Power, Current, Voltage, Power Factor and Frequency.(b) Abstract Download for Monthly and quarterly billing survey data for cumulative energy and max demand and tampering features.(ii) Multiple Payment Gateway with different Payment Modes such as Secure Mobile App/ PC Based/Swipe Machine/ Online Payment Gateway/all UPI platform/MRO based cash payment for all users assigned by BSO/GE. Gateway/Mode should be selected such that No transaction charges are levied/applicable to the admin (MES).(iii) Billing Module: Postpaid /Prepaid Billing Module:The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make the energy data/billing data available to admin to end users. The billing module would include functionaries for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required without any additional cost implication to the department.
61(Srl Item No. 59.00 Contd...)(iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.(v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.(vi) Energy Accounting ModuleThe system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter.(vii) Communication ModuleThe system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process.(ix) Excel Export:The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution.(xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself.
62(Srl Item No. 59.00 Contd...)(xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email.Notes - The additional functional requirements of MDMS are as follows: (A) Asset Management: i) Meter Location (Apartment, shop, industry/address etc).ii) Consumer Information (Name, Account, ID etc)iii) Meter details (Meter No. 1 phase/3 phase, with or without relay etc).iv) Meter Configuration (Demand integration period, load profile capture period etc).v) GIS information (connection, feeder/transformer/pole etc)(B) Meter data:i) Schedule and on demand meter reads and pinging of meter.ii) Storage of all connected meter events and alarm. (storing of 5 years data or more via archiving)iii) Provide complete history and audit trail for all data for 30 days (configurable period)iv) Handle net metering/meters at the same premises.v) Manage at a minimum 15 minutes interval data.
63(Srl Item No. 59.00 Contd...)(C) Data validation, Estimation and Editing (VEE): i) Registered Read Data: Daily Billiing Cycle, as well as derived billing determinants like TOU.ii) Interval Data: Variable intervals and variable units of measure.iii) Calculated Data: Derived or computed such as determinants billing and aggregated loads.iv) Event Data: Event and alarm data from meters, network equipment and MDMS itself. (D) Billing Determinants:i) Configuration multiple TOU/TOD options by customer type, day type (Weekend, Weekdays, and holidays) and by season.ii) Processing of interval data into billing determinants. a) Total consumption b) Consumption in different time blocks for TOU billing. c) Maximum demand (KW and KVA) d) Number of tamper counts e) Average power factor f) Ability for check metering, sub metering prepaid metering and net metering.(E) Exceptions:i) Capture and log data exceptions, problems and failures and send emails/SMS.ii) Generate exceptions for a) Meter tamper alerts b) Communication module health alerts c) Communication is less/more than pre-defined average consumption d) Negative consumption e) Power Outage f) Demand/Load g) Renewable Energy/EV
64(Srl Item No. 59.00 Contd...)(F) Customer Services:i) Access to current and historical consumption and interval data, outage flags, voltage and power quality indications.ii) Email/SMS notification of configured alarms and events to selected users.iii) Web portal to provide the consumer near real time online views of Usage and Cost, Alerts and Notifications and Mobile App.(G) Analysis:i) Consumption/load profiles. a) Configurable period (hours, day, month, year etc) b) Day type (Weekend, holiday, festival wise etc) c) Tariff, customer type, or any user specified collection of meters.ii) Peak and off peak load patterns by aggregating all loads of DT/Feeder/consumer group.iii) Feeder wise energy audit.iv) Load forecasting, load research.v) Ability to configure the system to effectively visualise consumption trends, identify unusual patterns, and visualise load analysis to understand which assets are being over utilised.(vi) Analysing tamper event data.
65(Srl Item No. 59.00 Contd...) (H) Reporting:i) Daily data collection report.ii) Usage exceptionsiii) VEE validations failures.iv) Physical meter events (install, remove, connect, disconnect) and meter resent report.v) Meter flags.vi) Meter inventory.vii) Defective meters.viii) Interface exception reports between MDM and other subsystems eg. billing, outage etc.
66Note for Srl Item No. 55.00 to 64.00 :- Operation including Rectification of defects/ Repair/ Maintenance of AMI Infra during 02 Yrs of Defects Liability Period:-The rate quoted against smart meter shall deemed to included for operation and rectification of defects/repair/maintenance of AMI system during the 02 yrs of. Defects Liability Period. They would include the following items:-(a) Software AMC: This would include necessary up-gradations in the software such as support to the chrome browser charges, android version charges, iOS version charges. These charges happen on frequent basis and the software would support all the charges.(b) Changes in the Government tariff structure: The Government tariff charges may require software upgrade. The same would be included in the AMC scope of work.(c) 24 x 7 customer care support: Ensuring adequate database backup, up-gradations in the operating system, anti-virus updates, data base upgrade etc.(d) Reports development: The additional reports as needed for the success of the project would be developed.(e) Software installation on any alternate/ backup server, if required.(f) The communication network monitoring and support.(g) Configuration of the repaired/ replaced hardware in the system.(h) Trouble shooting and necessary actions to run the system as required.(i) Software bug fixing as and when required.(j) Hosting the software to Government community cloud and management of supplied software application with standby server for all Smart Meters.(k) The GCC location would as per the approved MEITY list. In case a CSP is removed from the panel, the contractor would migrate to a new supplier.
67Note:- Schedule of credit (Sch 'A' Part- XIV) amount of Rs 19,203.20 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56180041
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28.50 Crore
LAST DATE 10-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Deficient Married Accn At Af Stn Dinjan
Basic Detail
Tender No 88683/DIN/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 27 Aug 2026
Submission Date 10 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value 28.50 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
BOQ_867433.xls
f07c468c-b3db-4c3e-bdbc-5e6e5509365e.html
TD1.rar
TD2.rar
TD3.rar
TD4.rar
Tender.pdf
Tendernotice_1.pdf
Tendernotice_2 (1).pdf
WD.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 06, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 13, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 03, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Aug 20, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 27, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 10, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 13 days
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_867433.xls

html

f07c468c-b3db-4c3e-bdbc-5e6e5509365e.html

rar

TD1.rar

rar

TD2.rar

rar

TD3.rar

rar

TD4.rar

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

rar

WD.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders