Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #56179935

Tender For Special Repair To Bldg No T-83, P-06, P-07, P-08, P-09, & P-10(Toilet Block), Tr-14 And P-32 At Sunderbani Under Ge(N) Akhnoor.

Issued by Statutory Bodies & Commissions/Committees · akhnoor, Jammu and Kashmir
Tender Value
34.16 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
6 days left
EMD
68500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
akhnoor → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No T-83, P-06, P-07, P-08, P-09, & P-10(Toilet Block), Tr-14 And P-32 At Sunderbani Under Ge(N) Akhnoor.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jul-2026 BOQ Corrigendum BOQ 16-Jul-2026
2 06-Jul-2026 Tender Corrigendum Other 16-Jul-2026

BOQ

Name of Work:- SPL REPAIR TO BLDG NO T-83, P-06, P-07, P-08, P-09, & P-10(TOILET BLOCK), TR-14 AND P-32 AT SUNDERBANI UNDER GE(N) AKHNOOR.
Sl. No. Item Description
1Taking down old unsv roof treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc incl disposing off debris from MoD land complete all as specified and directed.
215mm thick rendering in cement mortar 1:3 on concrete surfaces of roof and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
3Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) 1st Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer. (b) 2nd Course : Applying evenly a tack coat of industrial bitumen grade 85/25 conforming to IS-702 at rate of 1.2 Kg/Sqm. (c) 3rd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(d) 4th Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
4Preparation of new or unplastered surface of concrete not otherwise described over 10 cm width or girth and applying two coat of aluminium paint over roof surfaces complete all as specified and directed.
5Dismantling wall and ceiling boards, fibre pulp insulation etc or insulation boards/ slabs / blankets, any thickness, including cover fillets, frame work of any description etc, complete all as specified and as directed.
6Providing & fixing of 4mm thick designer ceiling board fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of Gl wire 4mm dia to be fixed by approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction complete all as specified & directed.
7Dismantling of AC corrugated or semi-corrugated in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed.
8Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
9Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa s in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified and as directed.
10Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
11Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
12Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
13Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified.
14Description all as per Item No 13 above but except stone set in CM 1:4 complete all as specified and directed.
15Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
16Rendering 15mm thick cement plaster with cement mortar(1:4) on other than fair faces of brick work or stone masonry surfaces or one side of lathing and finished even and smooth without using extra cement complete all as specified and as directed.
17Rendering 10mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick work or stone masonry surfaces or one side of lathing and finished even and smooth without using extra cement complete all as specified and as directed.
18Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and as directed.
19GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required all as spd and directed.
20Applying 3mm thick wall care putty in two layers over newly plastered surfaces of wall, complete all as specified and directed.
21Supply liquid water proofing compound all as specified and as directed.
22Complete removal of exising treatment of old surfaces all as specified and as directed.
23Preparation of new plastered and unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
24Preparation of old plastered and unplastered surfaces of wall and applying two coat of oil bound distemper complete all as specified and as directed.
25Preparation of new plastered and unplastered surfaces , applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces, complete all as specified and directed.Note:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE.(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
26Complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old plastered surfaces, complete all as specified and directed.Note:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE.(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
27Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed.
28Preparation of old decorated surface and applying two coat of Oil bound distemper on ceiling, complete all as speicfied and directed.
29Repair to balcony/ Facia and soffit of chajjas etc by taking down old rendering and applying 15 to 20mm thick cement plaster to match the existing thickness in CM 1:3 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm in width or girth including preparation of surface and applying two coats of apex as required over one coat of primer including necessary formwork/scaffolding work upto height 7mtr above ground level of bldg complete all as specified and as directed.
30Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed.
31Reinforced cement concrete (nominal mix) type B1 1:2:4 using (20mm graded crushed stone aggregatge) for Chajjas/Balcony/Landing work as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
32Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Vertical , Horizontal or sloping)sides including supports, overhangs, for fair finished surface of concrete etc. complete all as specified and directed.
33Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed.
34Mild steel bars 10mm dia TMT Bars and over cut to length bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs all as specified and directed.
35Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
36Plain cement concrete type B-0 1:2:4 (12.5mm graded aggregate) 25mm thick as in sub base of floors complete all as specified and directed.
37Vitrified ceramic tiles (light shade) 10mm thick (Square/rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and directed.
38Vitrified ceramic tiles(Light shade)10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in dado/skirting etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match in light shade including 10mm thick rendering in cement and sand mortar 1:4, complete all as specified.
39Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
40Glazed ceramic tile 450x300x7mm/600x300x7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in cement and sand mortar 1:4 complete all as specified.
41Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each and removing from site all as specified and as directed.
42Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed.
43Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 01 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 as in back fitting of pressed steel frame, complete all as specified and as directed.
44Solid PVC Door/ Almirah/Kitchen/Cupboard frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
45Factory made solid Panel PVC( door/almirah shutter/cupboard) shutter 30mm thick(wooden texture) (style) consisting of frames made out of MS tubes for tip and bottom rails M.S frames shall be covered with heat channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rails, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/slealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawing.
46Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
47Ditto as per item No.46 above But without glazing bars shutter only complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
48Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
49Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed.
50Aluminium powder coated Anodised aluminium window ( including glazed and skeleton shutter ) and ventilator shutters, side hung type without sash bars, aluminium sections weighing not 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.)suitable handle (1 no.)(thickness of powder coating should not less than 50 micron) complete all as specified.
51Door closer hydraulically regulated, aluminium anodised extruded section body designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.
52Anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern,with approved standard section and fixed to the existing window frame with frame with CP brass/stainless steel screws @200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.
53Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed.
54Extruded aluminium alloy handles, fabricated type, anodised of size 150mm and fixed, complete all as specified and directed.
55150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
56Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed all as specified and directed.
57Figured glass pin headed type, 4mm thick, glazing with oil putty in squares not exceeding 0.50Sqm in each pane, complete all as specified.
58Supply only 5.5 mm thick tinted sheet glass, selected quality and glazing with aluminium beads and rubber packing in square not exceeding 0.5 square metre in each pane, complete all as specified and as directed.
59Supply only 5.5 mm thick tinted sheet glass, selected quality and glazing with aluminium beads and rubber packing in square exceeding 0.5 square metre in each pane, complete all as specified and as directed.
60Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple, complete all as specified.
61Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
62Curtain rail, 20mm dia mild,chromium plated fixed with bracket,stops,rollers etc fixed and repairs with side all as specified and directed.
63Preparation of new steel and iron surfaces of any description exc 10 cm width or girth, priming with red oxide zinc chrome primer and painting with two coats of synthetic enamel paint complete all as specified and directed.
64Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
65Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
66Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed.
67Bituminous mastic filling, with 85/25 or 95/10 grade bitumen and coarse sand mixture 1:3 by weight (comprising of one part of heated bitumen and 3 parts of sand), 8cmx8cm filling the joints with mastic at the junction of bays of plinth protection to vertical sufaces all as specified and as directed.
68Cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified.
69Rotational moulded polyethylene water storage tanks of 1000 litres capacity,three layered and white in colour(cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed.
70Taking up or down steel water tubing and connections including cleaning and removing of 20 mm dia bore, complete all as specified and directed.
71Taking up or down steel water tubing and connections including cleaning and removing of 15 mm dia bore, complete all as specified and directed.
7220mm Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors incl fittings like wall clamps etc as required, complete all as specified and directed.
7315mm Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors incl fittings like wall clamps etc as required, complete all as specified and directed.
7415mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairs complete all as specified and directed.
7520 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairs complete all as specified and directed.
76Ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed of 20mm dia bore, complete all as specified and directed.
77Vitreous china wash down water closet pan pedestal pattern size 570mm x 460mm x 380mm in white colour excluding seat cover, flushing cistern and flush pipe fixed in repairs with \\"P\\" or \\"S\\" trap,including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.fixed in repairs, complete all as specified and directed.
78Plastic water closet seat cover white closed pattern with flat bottom and cover including mild steel chromium plated or aluminium hinges device complete all as specified and as directed.
79Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.2 meter long flexible spirochrome flex tube and ABS wall hook including making connections and fixed in repair in position complete in all respect as specified and directed.
80Toilet paper holder with flap recessed type stainless steel fixed in repairs, Complete all as specified and directed.
81Vitreous china squatting pan \\"Orissa Pattern\\" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'P' trap fixed in repairs including making good dismantled floor cement concrete M-15 (1:2:4) type B-1 (Using 20mm aggregate) complete all as specified and directed.
82PVC valve less, symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs, complete all as specified and directed.
83Vitreous china wash basin, white, flat back, size 550x400mm including CP mixer for mixing hot and cold water for pipe of bore 15mm, waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe and pillar tap etc., fixed in repairs complete all as specified and as directed
84Towel ring of brass chromium plated(150 mm dia) fixed with and including chromium plated brass screws and wooden/plastic cleats etc fixed in repair, complete all as specified.
85PVC connection 15mm size with PTMT nuts of length 600mm size fixed in repairs complete all as spd and directed.
86CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore including fixing in repairs complete all as specified and directed.
87Bib taps (Long body) for 15mm bore dia of pipe, fancy type chromium plated with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.
88CP grating with or without hole100 mm dia fixed in repairs all as specified and as directed.
89Chromium plated Soap dish, any type, fixed with plugs chromium plated brass screws fixed in repairs complete all as specified and as directed.
90600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial quality ply-wood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs, complete all as specified and as directed.
91Corner Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 Cm wide with chromium plated bracket guard and railing 60cm long fixed in repairs complete all as specified and directed.
92Glass shelf 600mm long consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing with brackets fixed in repairs all as specified and as directed.
93Taking down eaves gutters and rain water pipe , soil and waste pipe PVC or CI (any size or pattern ), including all fittings, heads , shoes bends , swan-necks etc all as specified and directed.
94110mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in floors etc., complete all as specified and directed.
9575mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in floors etc., complete all as specified and directed.
96PVC (SWR) bends any radius 110 mm bore with oval access door, complete all as specified and as directed.
97PVC SWR bends any radius 75mm bore with oval access door complete all as specified.
98PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
99PVC SWR 75mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
100PVC (SWR)110 mm bore junction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door all as specified and as directed.
101PVC junction, double (double Y), equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all as specified and directed.
102PVC cowls 110mm bore complete all as specified and directed.
103PVC cowls 75mm bore complete all as specified and directed.
104PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified.
105Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed.
106Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed.
107Demolition and breaking up drain pipes (Salt glazed ware) of 150mm internal dia set in cement mortar including demolition of concrete bed and haunching and removal of rubbish off the premises complete all as specified and directed.
108Concrete bed to drain pipes 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed.
109RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed.
110Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed.
111PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
112Rendering 15mm thick in cement mortar 1:6 on other fair faces of bricks work or stone surfaces and finished the surface even and smooth without using extra cement, complete all as specified and as directed.
113Precast reinforced cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work, complete all as specified and as directed.Note:-Reinforcement shall be measured & paid separately under respective item.
114Mild steel round bars 10mm dia and over as in manhole cover handles, steps, clamps etc conforming to Fe. 290 Gde E-65, complete all as specified and as directed.
115Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
116Removal of excavated material(soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
117Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed.
118Soakage well exc in any type of soil, foundation in pcc 1:3:6,well of honeycombed and soil in M-25 concrete including intercepting chamber,screen chamber brick work in CM,RCC cover slab in M-25/RR masonary/filling with brick bats (size 2.4 M dia X 3.00M deep) Drg No CE/TD-1202/03 sheet 1/2 & 2/2.
119Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified.
120Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed.
121Preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of alkali resistant primer, complete all as specified and directed.
122False ceiling grid galvanzed steel tee/ angle (Powder coated ) of grid size 600x600mm comprising of main and secondry tee ( weight not less than 240gm /RM) and wall perimeter angle (weight of section not less than 217gm/RM) all around of walls suspended with 4mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type including 4mm thick designer ceiling boards size 595x595mm fixed in position all as directed.
123Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:2:4 type B-1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
124Replacement of GI water tubing 40 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
125Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified.
126TMT bars, 5mm dia and over and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
127Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed.
128Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateform and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite including 15mm thick screed of CM 1:6 after applying cement slurry@3 kg/sqm of cement per sqm, complete all as specifie.
129Non skid coloured ceramic tiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
130Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement laid over & including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed.
131Ditto' all as per item above but in dado/skirting etc incl 10 mm thick rendering in CM 1:4 complete all as directed.
13240mm thick flush shutters, solid core with particle board exterior grade as per IS 2202 of 199 (Part-I) flush door shall be internally lipped as per clause .8.52.2 of SSR Part-I 2009, complete all as specified & as directed.
13335 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified.
134Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer,complete, all as specified.
135250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified.
136200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified.
137300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed, complete all as specified and directed.
13825 mm dia stainless steel curtain road complete with stainless steel bracket and side clamps fixed in position by drilling holes in wall and fixing the bracket with rawl plug and SS screw, fixed in repairs all as specified and as directed.
139Sheet glass ordinary quality, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed.
140Complete removal of old existing treatment of wall and applying 3mm thick wall care putty complete all as specified and directed.
141Preparation of newly plastered surfaces (3mm thick putty) of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
142Preparation of old painted surfaces by washing, rubbing down and stopping and applying one coat of cement base paint white or other tint on wall complete all as specified and as directed.
143Refixing old steel water tubing of 15mm bore and connections in new or old position fixed to walls, ceilings laid in floors etc. including provn of fittings as requiered, complete all as specified.
144Refixing of old steel tubing and connections in new or old position on walls, ceiling or laid in floors etc of size 20 mm bore after cleaning including provn of new fittings, complete all as directed.
145Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exc 20 cm girth Stone concrete block or slab walls all as directed.
146Tubular CP towel rail 60cm long 20mm dia D type aluminium anodised incl necessary brackets, fixed, complete all as specified and directed.
147PVC connection 15mm size with PTMT nuts of length 450mm size fixed in repairs complete all as specified and directed.
148Brass chromium plated fancy type wall mixture for mixing of hot and cold water supply screwed down including connecting leg & wall flange for iron pipe 15 mm bore fixed in repair complete all as specified and as directed.
149Rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, of capacity 500 Ltrs including 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed (including taking down existing water tank), complete all as specified and as directed.
150PVC SWR bends any radius 110 mm bore fixed in repairs, complete all as specified and as directed.
151PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
15275mm PVC (SWR) junction single, (single T) equal or unequal provided with access door, complete all as specified and directed.
153Roughening surfaces of old concrete floors by picking,sweeping clean and washing down with water to remove dust etc and brushing with neat cement slurry using cement at 3kg/sqm complete all as specified and as directed.
15410mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @3% by weight of cement on concrete roof suface finished fair and even to maintain the proper slope of roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed
155Cleaning of plastered roof surfaces and applying a coat of bitumen primer @0.30kg/Sqm on top of dry surface of finished cemet mortal plaster complete all as specifed and directed.
156One layer of APP based polymeric membrance minimum weighing 3kg/Sqm and minimum 3mm thickness reinforced with polyster non woven fabric (wt not less than 150gms/sqm ) land on primed surface by forced application complete all as specified. With lap of 100 mm and the over lap shall be sealed by flame complete all specified and directed.
157One coat of hot blown bitumen of grade 85/25 @1.2 kg/Sqm shall be applied over APP Membrance surface complete all as specified and directed.
158Chequered cement concrete tiles 30mx30cmx25mm thick laid & jointed with grey cement and pointed in neat cement slurry mixed with with pigment as in part/hardstanding laid over & including15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes all as specified and directed.
159Plain cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
160Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed. Please Enable Macros to View BoQ information
161Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56179935
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34.16 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No T-83, P-06, P-07, P-08, P-09, & P-10(Toilet Block), Tr-14 And P-32 At Sunderbani Under Ge(N) Akhnoor.
Basic Detail
Tender No GE(N)/AKH-10/2026-27
Bidding Type Tender
Location
City akhnoor
State Jammu and Kashmir
Key Dates
Publish Date 06 Jul 2026
Submission Date 16 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 34.16 Lakhs
Tender Fee 500
EMD 68500
Exemption Available
Document List
tender10.pdf
Tendernotice_1.pdf
8497052e-0a63-422e-a4d1-a75af7169391.html
BOQ_867579.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Jul 16, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

tender10.pdf

pdf

Tendernotice_1.pdf

html

8497052e-0a63-422e-a4d1-a75af7169391.html

xls

BOQ_867579.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender