| 1 | Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead of following sizes :- Note :- Old lead shall be reused. |
| 2 | 15 mm bore. |
| 3 | 20 mm bore. |
| 4 | 25 mm bore. |
| 5 | 40 mm bore. |
| 6 | 50 mm bore. |
| 7 | 80 mm bore. |
| 8 | 100 mm bore. |
| 9 | 150 mm bore. |
| 10 | 200 mm bore. |
| 11 | Refixing GI steel tubing and connections in new or old position including cleaning internally and externally, any grade / make (in trenches / wall / floor / ceiling) including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of following sizes:- |
| 12 | 15 mm bore. |
| 13 | 20 mm bore. |
| 14 | 25 mm bore. |
| 15 | 40 mm bore. |
| 16 | 50 mm bore. |
| 17 | 80 mm bore. |
| 18 | Supply, fixing, laying and jointing GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings and laid in trenches/wall/ceiling/ floor/ all as specified and directed of following sizes:- |
| 19 | 15 mm bore. |
| 20 | 20 mm bore. |
| 21 | 25 mm bore. |
| 22 | 40 mm bore. |
| 23 | 50 mm bore. |
| 24 | 80 mm bore. |
| 25 | Refixing (DI) Ductile Iron pipe and connections in new or old position including cleaning internally and externally, any grade / make (in trenches / wall / floor / ceiling) including all type of new fittings all as specified and directed of following sizes:- |
| 26 | 100 mm bore. |
| 27 | 150 mm bore |
| 28 | 200 mm bore. |
| 29 | Supply, laying, jointing and testing (DI) Ductile Iron pipe pressure flanged type, class K-7 suitable for rubber gasket joints in standard working length confirming to IS-8329/2000 with inside cement mortar lining duly ISI marked laid in trenches complete all as specified and directed of following sizes : - |
| 30 | 100 mm bore. |
| 31 | 150 mm bore |
| 32 | 200 mm bore. |
| 33 | S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe of following sizes: - |
| 34 | 15 mm bore. |
| 35 | 20 mm bore. |
| 36 | 25 mm bore. |
| 37 | 40mm bore. |
| 38 | 50 mm bore. |
| 39 | M&L for run lead joint with spun yard & head for spigot and socketed end CI/DI pipe & fittings complete all as specified and directed for following sizes:- |
| 40 | 100 mm bore. |
| 41 | 150mm bore. |
| 42 | 200mm bore. |
| 43 | 250mm bore. |
| 44 | Supply and fix cast iron flanged sluice valve of class 1.6 PN installed complete with ISI marked (IS-14846) with gun metal spindle and hand wheel all as specified and directed including taking down old unserviceable one of following sizes : - |
| 45 | 80 mm bore |
| 46 | 100 mm bore. |
| 47 | 150mm bore. |
| 48 | 200mm bore. |
| 49 | 250mm bore. |
| 50 | S & F in repair cast iron Non Return Sluice Valve of class PN 1.6 installed ISI marked (IS-13095) complete all as specified and directed. |
| 51 | 150mm bore. |
| 52 | 200 mm bore |
| 53 | M&L for CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. |
| 54 | M&L for CI Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth complete all as specified and directed. |
| 55 | M&L for Rubber gasket joint all as specified and directed including taking down old unserviceable one of following sizes : - |
| 56 | 100 mm bore. |
| 57 | 150mm bore. |
| 58 | 200mm bore. |
| 59 | M&L for Repacking stuffing box of sluice valve spindle including taking apart and reassembling tesing complete. |
| 60 | 80 mm bore |
| 61 | 100 mm bore. |
| 62 | 150mm bore. |
| 63 | 200mm bore. |
| 64 | 250mm bore. |
| 65 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe in soft / loose soil and getting out complete all as specified and directed. |
| 66 | Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 67 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed. |
| 68 | S&F in Replacement of 20 mm Dia Float Valve with PVC float ball, suitable for water tank, including all fittings , nuts, washers and connection with existing pipe line, complete all as specified and directed. |
| 69 | Core cutting / drilling of Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia including necessary machineries complete all as specified and directed. |
| 70 | Cutting the existing road of any kind straight by manual, depth and width not less than 30 cm for pipes up to 150 mm dia and 60 cm for pipes from 150 mm to 250 mm dia and 75 cm for pipes above 300 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 71 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping & plastering of valve chamber / supportring of pipe/ for hard standing including shuttring work complete all as specified and directed. |
| 72 | M & L for Construction of brick masonry valves pits, of size 900 mm x 900 mm x 900 mm, complete with 3.15 mm thick MS sheet cover and angle iron frame duly painted with locking arrangement including excavation, earth work and PCC as required complete all as specified and directed. Please Enable Macros to View BoQ information |