| 1 | Street Light |
| 2 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover andsecondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external insidedriver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .LED Street Light fixture with Minimum lumen output 3700 lm |
| 3 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P -1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .32 mm Dia. |
| 4 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 4.0 sq.mm |
| 5 | Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A'attached with this BSR. LT cross arm 600 mm long with clamp |
| 6 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 100mm x 70mm |
| 7 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 75mm x 90mm |
| 8 | Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per preapproved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) |
| 9 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed UnArrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 16.0 Sq. mm 4 core |
| 10 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire |
| 11 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM |
| 12 | SITC of IK 10 & IP65 3 phase 440V 50Hz, 7.5kw capacity centralized control and monitoring system panel (CCMS) made of fire retardent SMC steel material having lock system suitable for schedule on/off ofDedicated control & metering unit.pre programmed on/off schedule& remote on/off operation in case of bad weather/emergency/maintenance. Bypass faciltiy per phase. Data capture of Energy consumption & other electrical data in real time & at pre deterimned interval.RTC controller should be type tested in NABL approved lab & should be compitable with communication module 2G/4G which transmit data wirelessley and recorded to dedicated server or on cloud based architecture and aslo give command for schedule on/off of cluster of lights. Latiching relay/Bi-stable switch/isolation device should conferming to IEC-61-36/61037 & contactor also conferming to relevant IEC/IS standard13779.MCB conferming to IEC-62053/62054. With included Controller also have functional specification is for A) Lux sensor & Astronomical Clock mode: 1) For switching ON-< 60 lux for >30 sec or Twilight Duskwhichever is later 2)For switching OFF->10 lux for >30 sec OR twilight Dawn whichever is carlier and B) for time schedule mode For switching ON/OFF-Time selected by userController should connected to separate lithium battery to provide back up of minimum 8 hours in case of power outage.*unit should be supported by web/app based software package with detail information dashboard.*pole mounting/surface mounting stand *inclusive of 2 year server & website hosting charges.Comprehensive on-site warranty of above Central Control & Monitoring System (CCMS)- Street Light Controller including SIM card or any other maintenance charges for 2 years. Please Enable Macros to View BoQ information |