Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 50001728Construction of embankment with approved materials diposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting to meet requirement of table 300-2 & Clause 305 S.r 3.17 of MoSRT&H Spection for road & bridge work.Ground Floor |
| 2 | 50004059Providing & lying Bituminous macadum with hot mix plant using Crushed aggregates of grading-II materials,premixed with bituminous binder transported to site,laid over previously prepared surface with paver finiher to the required grade level & allignment & rolled to achive desired compaction as per clause-504 of MoRT& H specification for road & Bridge Works (4Th Revision).(AR-P-169/45).Ground Floor |
| 3 | 50008453Providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.60 kg/ sqm. using mechanical means as per clause 502 of MoSRT & H Specifications for road & bridge works(4th revision)(AR-2006-Page-167-Item-43)Ground Floor |
| 4 | 50008455Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.2 kg/sqm on the prepared bitumen/granular surface cleaned with mechanical broom as per clause 503 of MoSRT & H Specifications for road & bridge works(4th revision)(AR-2006-Page-168-Item-44)Ground Floor |
| 5 | 50011103Painting runway/taxi/track/apron marking with adequate nos of coats (minimum 2coats) to give uniform finish with road marking paint Based on solvent based acrylic resin has UV resistant colours of superior make (water based) i/c cleaning the surface of all dirt scales, oil, grease and other foreign material etc. and lining out complete. For new road work. Ref: DSR-16.47.1.Make(Asian paints:APCOTRAK, Berger:ROAD MARKING PAINT, Dulux :PROFESSIONAL WEATHER SHIELD ANTI-CARB)[NEW-NSWI]Ground Floor |
| 6 | 50011105Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using Hot applied thermoplastic compound conforming to ASTM: D36 or BS 3262 (Part-I) by fully/ semi automatic Thermoplastic paint applicator machine fitted with profile shoe, Reflectorising glass beads conforming to BS:6088 and BS 3262 (Part-1) dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P,cleaning the road surface of all dirt,seals,oil,grease and foreign material etc.complete and accordance with applicable specifications Ref: DSR-16.62.[NEW-NSWI]Ground Floor |
| 7 | 50011883Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 .Ground Floor |
| 8 | 50013578Providing, Laying, spreading & compacting graded stone aggregate of to W.M.M. specifications including premixing material with water at OMC in mechanical mix plant and carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with VRR to achive the desired density as per Clause 406 of MoRT&H specifications for Road & Bridge Work (4th Revision).(AR-P-166/42).Ground Floor |
| 9 | 50013582Providing & Laying Semi Dence Bituminous Concrete with Hot Mix Plant using crushed aggregates of grading-II materials,premixed with bituminous binder, transported to site, laid over previously prepared surfase with paver finiher to required grade level & allignment & rolled to achive desired compaction as per clause-508 of MoRT &H specification for Road & Bridge Works (4th Revision).(AR-P-175/47)Ground Floor |
| 10 | 10000556Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH.Ground Floor |
| 11 | 10000564Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor |
| 12 | 10000570Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor |
| 13 | 10000583Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSBGround Floor |
| 14 | 10000588Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme.Ground Floor |
| 15 | 10000594Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/AerolexGround Floor |
| 16 | 10000596Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation).Ground Floor |
| 17 | 10000600Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete.Ground Floor |
| 18 | 10000602Installation charges pump set with all accessories including transportation etc.Ground Floor |
| 19 | 10001184Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEXGround Floor |
| 20 | 10001190Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.1.5HP, Single phase,32D,19 Stage (head 50-129m). Make: KSB(2C/21).Ground Floor |
| 21 | 40000946Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 22 | 40000976Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 23 | 40000982Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 24 | 40000985Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 25 | 40001000Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 26 | 40001024Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI)Ground Floor |
| 27 | 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor |
| 28 | 40001129Supplying and fixing of 6\\"X4\\" 16/18 swg,2 \\" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam)Ground Floor |
| 29 | 40001151Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 30 | 40001237Supply and fixing of 4 way , single Door MCB Box with 1 No 32 Amp. DP MCB & 2 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.,2.7, )Make-MCB-(Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC)Ground Floor |
| 31 | 40008124Supply & fixing of 400mm (16\\") wall mounted fan with complete accessories[brown/white].including hanging and connections [MAKE- USHA MODEL-MIST AIR DUOS/ CROMPTON MODEL-TROPEDO HI SPEED//HAVELLS/V-GURAD MODEL-PETAL WF 17/ANCHOR)Ground Floor |
| 32 | 40008291Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing)Ground Floor |
| 33 | 40008393Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001)Ground Floor |
| 34 | 40008399Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON(MODEL NO-TRP-415-25-57-SL-LM-NBK)/ PHILIPS(MODEL NO-BRP029 LED25S 25W 2500LM)/ WIPRO)Ground Floor |
| 35 | MIS-CVL-BOUNDARYWA |
| 36 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 37 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 38 | 50000008\\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \\"Ground Floor |
| 39 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 40 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 41 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 42 | 50001305Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor |
| 43 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 44 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 45 | 50010444Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM)Ground Floor |
| 46 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 47 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 48 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 49 | MIS-CVL-COWCATCHER |
| 50 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 51 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 52 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 53 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 54 | 50005727Prividing,Fittin & fixing of cow catcher,made out of steel work (TATA make GI pipe circular hollow of 100 mm OD as per IS 1239[P-1] 4 mm thick) including RS joist of size ISLB 150X80 with cutting requird size ,welding using MS flat of 40X6mm size,fixing in position with approvd design and specification including all fitings and applying a priming coat of approvd steel primer etc all complete as per the direction & instruction of the Engineer-in-charge of the work.DATA FOR size 16'X5'= 80 sftGround Floor |
| 55 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 56 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 57 | 50011560Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 58 | MIS-CVL-ENTRY&EXIT |
| 59 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 60 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 61 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 62 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 63 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 64 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 65 | 50010446Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS)Ground Floor |
| 66 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 67 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 68 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 69 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 70 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 71 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 72 | MIS-CVL-RCCDRAIN |
| 73 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 74 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 75 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 76 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 77 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 78 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 79 | MIS-CVL-RCCRETAINI |
| 80 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 81 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 82 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 83 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 84 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 85 | 50010839Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX.Ground Floor |
| 86 | 50011560Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 87 | MIS-CVL-SENTRYPOST |
| 88 | 50000001Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth.Ground Floor |
| 89 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 90 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 91 | 50000019\\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \\"Ground Floor |
| 92 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 93 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 94 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 95 | 50000073\\" Random rubble H.G. stone masonary in cement mortar (1:6) in foundation and plinth per 1 cum. \\"Ground Floor |
| 96 | 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor |
| 97 | 50001305Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor |
| 98 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 99 | 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor |
| 100 | 50010408Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM)Ground Floor |
| 101 | 50010444Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM)Ground Floor |
| 102 | 50010446Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS)Ground Floor |
| 103 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 104 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 105 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 106 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 107 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 108 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 109 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Ground Floor |
| 110 | a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC),JK SUPER(PSC),JINDAL PANTHER(PSC) |
| 111 | APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK |
| 112 | CESS Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail