| 1 | MIS-CVL-BOUNDARYWA |
| 2 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 3 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 4 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 5 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 6 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 7 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 8 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 9 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 10 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 11 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 12 | 50010408Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM)Ground Floor |
| 13 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 14 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 15 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 16 | MIS-CVL-BOXTYPECUL |
| 17 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 18 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 19 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 20 | 50000738Providing and laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 21 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 22 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 23 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 24 | 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor |
| 25 | 50011616Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING)Ground Floor |
| 26 | 50011700Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 27 | MIS-CVL-MSGRILLGAT |
| 28 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 29 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 30 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 31 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 32 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 33 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 34 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 35 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 36 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 37 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 38 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 39 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 40 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 41 | MIS-CVL-PAVERROAD |
| 42 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 43 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 44 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 45 | 50001701Providing and laying 80 mm thick Factory made cement concrete interlocking Paver block of M40 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge.Ground Floor |
| 46 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 47 | 50011883Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 .Ground Floor |
| 48 | MIS-CVL-RCCDRAIN |
| 49 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 50 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 51 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 52 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 53 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 54 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 55 | MIS-CVL-SITEDEVLOP |
| 56 | 50006323Filling & Leveling of site by JCB.[N.S.W.I]Ground Floor |
| 57 | 50010875Supplying, filling or Spreading of moorum by mechanical means including cost of all labour,material T & P etc. complete as per the direction of Engineer-in-charge.Ground Floor |
| 58 | 50014318Vibrator Roller to be used for compacting & watering purpose.Ground Floor |
| 59 | MIS-CVL-UGR(1LAKHL |
| 60 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 61 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 62 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 63 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 64 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 65 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 66 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Ground Floor |
| 67 | 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor |
| 68 | 50011616Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING)Ground Floor |
| 69 | 50011664Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR TIE BEAM).Ground Floor |
| 70 | 50011700Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 71 | 50011926Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF)Ground Floor |
| 72 | MIS-INE-LIGHTNINGP |
| 73 | 40002086Air-Terminal Supply, Installation, Testing & Commissioning of Early Streamer Emission (ESE-30))type Lightning Air Terminal. Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5″ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity of that area. Protection Radius :- 48 Mtr Make :- ABB / STROMKING/VTR All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 74 | 40002089Lightning Strike Counter Supply, Installation, Testing & Commissioning of non-electronic & non-resettable (Not require any external power supply) type lightning strike counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(6/7 digit) Make :- ABB / STROMKING/VTR All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Engineer-in-Charge.Ground Floor |
| 75 | 40002095Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL/VTR All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 76 | 40002098Supply, connection &Testing of sub earthing with 16 Sq.mm single core multi stranded copper flexible wire from surge protection device (SPD) panel to earth electrode & Main panel board to SPD panel including all accessories, cable socketing and connections. Make :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-ChargeGround Floor |
| 77 | 40002101Supply, Installation, Testing & Commissioning of indoor type wall mounted Surge protection device (SPD) panel made of 2 mm thick CRCA sheet, dust and vermin proof duly powder coated having the following arrangement & complete factory wired by 16 Sq.mm single core multi stranded copper flexible wire. [A] Type 1+2 AC Surge Protection Device (SPD) (TP+N) (50 KA) - 01 Set [B] 63 Amp. HRC fuse with link – 03 Nos [C] 100 Amp. 4 pole stud connector – 01 No Make of SPD & HRC Fuse :- HAVELLS / L&T / LEGRAND/VTR Make of Wire :- FINOLEX / ANCHOR / HAVELLS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 78 | 40002720Supply and laying of 70sqmm single core FR PVC insulated unseathed copper conductor for voltage grade 1100 volt as per IS-694 in sur face/underground as required(sl no-5.5.2)(Make-KEI/FINOLEX/HAVELLS)Ground Floor |
| 79 | a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC),JK SUPER(PSC),JINDAL PANTHER(PSC) |
| 80 | APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK |
| 81 | CESS Please Enable Macros to View BoQ information |