|
| 1 | wiring |
| 2 | 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters |
| 3 | 90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 4 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 5 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 6 | OD529038/2025-2026:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete |
| 7 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 8 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 9 | 1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 10 | OD529017/2025-2026:Supply,installation,testing and commissioning of Digital time swtch 40A, 2pole , AC1 rated power contactor with 1NO+1NC auxiliary contacts with AC coil and 24 Hours timer for operating automatic ON-OFF function suitable for single phase supply |
| 11 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 12 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 13 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 14 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 15 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 16 | OD529016/2025-2026:5 mm X 3 mm G.I. strip earth lead Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 17 | OD529036/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-6535-STD-NF] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required |
| 18 | OD529014/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc |
| 19 | OD529015/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 20 | OD529018/2025-2026:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 21 | OD529020/2025-2026:Supplying and fixing of following sizes of light class PVC conduit along with accessories in surface/ recess including cutting the wall/ground and making good the same in case of recessed conduit as required as service pipe |
| 22 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 23 | OD529023/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required Please Enable Macros to View BoQ information |