Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 2 days TDR #56176915

Tender For Electrification Of Sewer Store, Q Block Mangolpuri Ac-12.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Jul 2026
2 days left
EMD
13200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrification Of Sewer Store, Q Block Mangolpuri Ac-12.

BOQ

Name of Work:- Electrification of Sewer Store, Q Block Mangolpuri AC-12.
Sl. No. Item Description
1S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. 1 or 2 modules DSR 2022 1.27.1
26 module DSR 2022 1.27.4
3S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including ,painting etc DSR 2022 1.57
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sqmm DSR 2022 1.17.12
53 x 4 sqmm DSR 2022 1.17.21
63 x 6 sqmm DSR 2022 1.17.30
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm earth wire. DSR 2022 1.14.5
8Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B DSR 2022 1.10.2
9Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch DSR 2022 1.24.1
103 pin 5/6 amp socket outlet DSR 2022 1.24.4
1115/16 amps switch DSR 2022 1.24.3
126 pin 15/16 amp socket outlet DSR 2022 1.24.5
13Bell push DSR 2022 1.24.7
14Supplying and fixing of modular blanking plate on the existing modular plate and switch box excluding modular plate as reqd. DSR 2022 1.26
15S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc DSR 2022 1.32
16S/F of brass batten/angle holder including connections etc as reqd DSR 2022 1.34
17Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 2022 1.25
18S/F of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm DSR 2022 1.21.2
1920mm DSR 2022 1.21.1
20Providing and fixing of 48\\" ( 1200 mm ) ceiling fan with all accessories and making connection etc as reqd. at site ( Havells/ CG / Orient/ Usha/Almonard/DJB approved ) DJB SOR 20.1.2
21Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. as required, DJB SOR 5.2
22Providing and laying earth connection From earth electrode with 6 SWG dia G.I wire in 15 mm G.I Pipe From earth electrode including connection with G.I thimble excavation and refilling as reqd. DJB SOR 5.12
23Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (DSR 2021 civil 15.7.4 )
24Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) ( DSR 2021 civil code 4.1.8 )
25Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door ( DSR 2022 code 2.3.3 )
26Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole ( DSR 2022 code 2.10.1 )
27Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2022 2.12.2
28Supplying and fixing of bell buzzer suitable for single phase 220 volt i/c making connection etc as reqd. at site DSR 2022 1.38
29Installation, testing and commissioning of 48\\" ceiling fan including wiring the down rods standard length single core copper conductor cable etc as reqd. at site. DSR 2022 1.44
30Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required 4 x 16 sq. mm DSR 2022 9.1.33
31Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1.KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm. ( DSR 2022 code 7.1.1 )
32Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle) ( DSR 2022 code 7.7.1
33Installation, testing and commissioning of LED fitting of all type complete with all accessories directly on ceiling wall including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc as reqd. at site. ( DSR 2022 code 1.41
34Supplying and fixing of 65 mm dia \\" G.I street light pole , 4.5 mtr long approx. heavy duty complete with 65/32 reducer including 1' x 1' G.I base plate etc. as reqd.at site
35Erection of G.I pole of length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre
36Supplying of 100 watt flood light fitting pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mm and 6500 colour with lumens 15500 with all accessories etc as etc as reqd. at site.( Make : Crompton/Havells/DJB approved )
37Painting of street light poles with Primer and 2 Coats of High gloss Enamel Paint. Make:- Asian/Berger/Nerolac.
38Installation of LED light flood light 100 Watts with all safety measures with the help of skilled labour/technician as required.
39Supplying and fixing of angle frame of suitable size ( 50\\" x 50\\" ) including excavation and repairing the same etc as reqd. at site.
40Supplying and fixing of 32 mm dia X 1.80 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 1 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. This also include supply & fixing of 2 Nos, 32 mm dia X 1.8.0 metres long G.I. pipe with bend for junction box.
41Supplying of 2\\" HDPE flexible PVC pipe complete with all accessories i/c jointing and making good the same etc as reqd. at site
42Supply of SMC junction boxes anti-corrosive water resistant, UV protected, High temp resistant, weatherable and suitable for all kinds of climatic conditions. Self-colour fire retardant and high dielectric strength maintenance free. Make: Bajaj / Hensel / Syntex/Other DJB approved make
43Higher Wattage Decorative ultra slim aluminum LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. 24 W LED 6500 K DJB SOR 19.3.1
44Supply of XLPE insulated, PVC sheathed Al.conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 16 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved.
45Supply of XLPE insulated, PVC sheathed Al.conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 3 x 6 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved.
46Providing of 15\\" ( 380mm ) exhaust fan with all accessories and making connection etc as reqd. at site ( Havells/ CG / Orient/ Usha/Almonard/DJB approved ) DJB SOR20.2.1
47Installation, testing and commissioning of exhaust fan including wiring the down rods standard length single core copper conductor cable i/c if wooden work is required etc as reqd. at site
48Supply, installation, testing and commissioning 3' x 3' feet size cubical panel wall mounted 3 phase 4 wire system and dust proofed the cubical panel made of 16 gauge CRCA sheet supported on angle channel. The door shall be made out of 16 gauge CRCA sheet duly painted and having aluminium bus bar the 25 x 10 size following. 3 output (1output per phase) and suitable for three phase supply power supply connections by fixing the incoming - 125 amp MCCB – 1 No.and outgoing 100 Amp - 1 nos , TP MCB - 3 nos, DP MCB -6 No. SP MCB 5 ampto 32 amp - 8 nos , 3 No’s indicating LED etc as reqd.
49New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07.DJB SOR 19.10.6
50Installation of LED light 70 Watts on street light Pole after erection with all safety measures with the help of skilled labour/technician as required.
51Loading, unloading, cartage and transportation charges for the above pole up to the side i/c charges of heavy labour etc. as per site requirement.
52Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56176915
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 03-07-2026
Authority
Authority Name Delhi Jal Board
Work Description Tender for Electrification Of Sewer Store, Q Block Mangolpuri Ac-12.
Basic Detail
Tender No NIT No.04 /EE(EnM)M-8/2026-27 Item 11
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Jun 2026
Submission Date 03 Jul 2026
Open Date 03 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 13200
Exemption Available
Document List
BOQ_391427.xls
ceb43450-4098-49df-aad5-9b9d6516c570.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_391427.xls

html

ceb43450-4098-49df-aad5-9b9d6516c570.html

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders