| 1 | Power plug wiring in PVC conduit (2x4 sq. mm) Wiring for light/power plug with 2x4 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 3 | 2x6 sq.mm + 1x6 sq.mm earth wire |
| 4 | 4x10 sq.mm + 2x6 sq.mm earth wire |
| 5 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 7 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 8 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 9 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket oulet and complete with connections, testing and commissioning etc. as required. |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group A |
| 11 | Group B |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connectionsetc. as required. |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch,connections etc. as required. |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 amps switch |
| 15 | (b) 3 pin 5/6 amp socket outlet |
| 16 | (c) 15/16 amp switch |
| 17 | (d) 6 pin 15/16 amp socket outlet |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 19 | Supplying and fixing brass batten/ angle holderincluding connection etc. as required. |
| 20 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 DELHI SCHEDULE OF RATES (E&M)-2025 (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 21 | LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning ofLED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22watt |
| 22 | SITC of Air fresher fan 8 inch 200mm 50 Hz 230V warranty 02 years from the date of supply Make:- Havells/Crompton/Orient/Usha |
| 23 | SITC of exhaust fan double ball bearing heavy duty, 12\\" (300mm sweep)complete with motor, 3/4 blades sets down double ball bearing and motor should be copper winding performs well at low voltage, RPM 1400, 220/240 V, 50 HZ, Grey colors. warranty 02 years from the date of supply, Make:- Usha/ Havells/ Crompton/Bajaj |
| 24 | SITC of Instant Water Heater (Geyser), 3 Ltrs, Heating Element Incoloy Glass Coated Heating Element, Rated Pressure 8 Bar, Feroglass ted Tank, Power Consumption 300O W, Requirement, Ac 230 V, 50 Hz, 2 Years Comprehensive Warranty on Product, 5 Years warranty on Inner Container and 2 Years warranty on Heating Element. Make:- Havells/ Racold/ Crompton |
| 25 | SITC of Storage Water Heater (Geyser), 25 Ltrs, Heating Element Incoloy Glass Coated Heating Element, Volume(L) – 25 Power(kW) – 2 Voltage/ Frequency(V/Hz) – 230/50 Temperature (°C) – 25-75 Rated Water Pressure(KG/cm2) – 6 & 8, Requirement, Ac 230 V, 50 Hz, 2 Years Comprehensive Warranty on Product, 5 Years warranty on Inner Container and 2 Years warranty on Heating Element. Make:- Havells/ Racold/ Crompton |
| 26 | Deduct - Credit Please Enable Macros to View BoQ information |