| 1 | Part A: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 2 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 4 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 7 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 9 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 10 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm |
| 11 | S/I/T/C of architectural column light pole made of mild steel with overall height of not less than 4 mtr. Duly finished with four coats of protection coating viz. etch primer, epoxy primers, polyurethane and glass clear respectively (each coating should not be having an average thickness of 65 micron). Light column in square cross section 220 mm × 220 mm made of mild steel housing components in square cross section having minimum weight 120 kg. Including a laser profile jali pattern (~1.5 m ht of MS laser cut sheet), cladded with opal acrylic diffuser, 4 × 36 Watt LED source and additional 4 Nos. 9-12W LED each post-top head, black in colour, coated for high corrosion resistance, silicone gasket, SS fasteners, foundation bolt of size 20 mm × 600 mm (N.S.) – 04 Nos. & foundation base plate of size (N.S.) 325 mm × 12 mm (L × W × H) – 01 No. and integral driver, IP65, IK>07 for the complete light fixture including non-metallic portion; and installation accessories.360° LED light distribution in the column part provided and low glare indirect line of vision. Efficacy >85%, THD <10%, PF >0.9, Surge protection >4KV. CCT 3000K, CRI >70, SDCM <4 & IK >07. Life of LED – 50,000 burning hours, suitable size of service window having prewire earth connection. Integral junction chamber for cable termination including providing and fixing 4-way 32 Amp heavy duty connector – 3 Nos. and 1 No. 6 Amp SPMCB, 10KA “C” curve including making connections, testing on load complete etc. as required. |
| 12 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L) ×600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1160 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1600 mm (approx) -8 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 20mm dia, 700/750 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 7m and 8 mtr pole. |
| 13 | P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. |
| 14 | Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge |
| 15 | Part B: AMC For 2nd Year @ 3% of Total part A (1834266) |
| 16 | AMC For 3rd Year @ 4% of Total part A (1834266) |
| 17 | AMC For 4th Year @ 5% of Total part A (1834266) |
| 18 | AMC For 5th Year @ 6% of Total part A (1834266) Please Enable Macros to View BoQ information |