Tender for Maintenance Of Road Side Lightening Works And Misc Electrical Items Under Ge(N) Akhnoor
BOQ
| Sl. No. | Item Description |
| 1 | Labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e. Axe, rope & ladder etc.) complete all as specified and directed. |
| 2 | Dismantling and taking down street light fittings/Post Top Lantern/down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to MES store and refixing after repair on required location complete all as directed.Note: Accessories or components needed for replacement shall be measured and paid separately under appropriate items. |
| 3 | Repairing of unserviceable LED street light any make/model of 90–100 Watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection complete all as specified and directed. |
| 4 | Repairing of unserviceable LED street light any make/model of 60–72 Watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection complete all as specified and directed. |
| 5 | PVC conduit ‘medium grade’ of size 15 mm bore including fittings, ISI marked, fixing with PCC pole/steel tubular pole/garden lights/gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp, nut & bolt, complete all as specified and directed. |
| 6 | Replacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm twin core complete all as specified and directed. |
| 7 | PVC insulation tape of width 18 mm, thickness 0.125 mm, length 25 mtr, ISI marked, for proper insulation of joints in wire where required or directed. |
| 8 | Replacement of Aluminium PVC service wire 2 core 6 Sqmm Flat roll of 90 mtr, superior quality, complete all as specified and directed. |
| 9 | Disconnecting & dismantling of damaged/unserviceable cable of any type/make and Supply & Laying in repair/replacement of cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty), 1100 Volts grade with stranded aluminium conductor using lugs/ferrules at both ends of cable and testing complete all as directed for following sizes: |
| 10 | 10 Sqmm 4 crore |
| 11 | 16 Sqmm 4 crore |
| 12 | 25 Sqmm 3.5 crore |
| 13 | 35 Sqmm 3.5 Crore |
| 14 | Note for Item No. 17 & 18: Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured and paid separately. |
| 15 | Excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr depth, getting out for electric cable complete in any type of soil complete all as specified and directed. |
| 16 | Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed. |
| 17 | Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 18 | Supply and laying sub class ‘B’ bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed. |
| 19 | Sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable) complete all as specified and directed. |
| 20 | Replacement of 40 mm GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/as garden post including 2 Nos mild steel FI clamps 35×3 mm size to support pipe with pole complete all as specified and directed. |
| 21 | Boring under road horizontally of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/loose soil complete all as specified and directed. |
| 22 | Applying two coats of aluminium paint over a coat of red oxide on steel tubular pole of 9–11 mtr length including cross arms and clamps except embedded portion of pole in ground and concrete, after removing old painted surfaces by scraping of poles complete and making colour band with synthetic enamel paint of approved colour up to 1.2 mtr from coping level including numbering of poles in 150 mm dia of approved colour paint complete all as specified and directed. |
| 23 | Taking down (from High Mast) of single phase electric operated search light motor of capacity 2 HP, dismantling & rewinding with existing gauge size copper wire and existing number of turns of coils for maintaining existing capacity of the motor and varnishing, drying, refixing & testing for proper rotation of search light fitting at watch tower complete all as specified and directed. |
| 24 | Replacement of Flexible LED Strip Light 25W, 240 LED, IP-68, high brightness, transparent, heat resistant, waterproof and anti-dust with PVC covering, visible in dark from far distance, fitted with suitable connectors for interconnection along with driver complete, plug and socket arrangement suitable to be fitted on edges of buildings, pathways and outer periphery of boundary walls, main gates, hard standings etc., complete with clamping at suitable distance to take the shape of required physical structure of Warm White/Dark Blue colour, all as directed and specified. |
| 25 | Replacement of internal LED Aviation Light comprising aluminium housing with polycarbonate enclosure including provision of three-core copper conductor cable of size 2.5 Sqmm, 3-core with white covering for making connection, fixing the fitting on wall including all necessary fixing accessories complete all as directed and specified |
| 26 | Replacement of Pole Box three phase of size 205 × 255 × 112 mm made out of 2 mm MS sheet, factory made with inbuilt locking arrangement, outdoor type, fixed to pole with suitable MS clamp comprising aluminium busbar 16 Amp, 04 Nos fixed on epoxy insulated pole and MCB 6 Amp, 10 kA, 240 Volt complete all as specified and directed. |
| 27 | Replacement of new generation Post Top Luminaire, energy saving, environment friendly, long life, aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser, IP-65 protection luminaire with high power LEDs as light source of 26 Watt, colour temperature 4000 K, including connection with PVC insulated & sheathed stranded copper conductor cable 3-core, 2.5 Sqmm complete all as specified and directed.Make: Havells / Philips / Benlo / HPL / Crompton or as approved. |
| 28 | Replacement of LED Street Light Fitting 60 Watt, lens type, high-pressure die-cast aluminium housing, minimum 140 lumen/watt system efficacy, Beam Angle 120°, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting electrically using 3-way 10 Amp connector and S&F PVC conduit 20 mm and PVC copper cable 2.5 Sqmm, 3-core from junction pole box to fitting complete all as specified and directed. |
| 29 | Ditto All as per item No 28 but LED Street Light Fitting of 70 Watt. |
| 30 | Ditto All as per Item No. 28 but LED Street Light Fitting of 90 Watt. |
| 31 | Replacement of LED Flood Light Fitting of 100 Watt, high-pressure die-cast aluminium housing, minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant polycarbonate glass (IP-66 protection), high impact resistance (IK07) with surge protection level until 4 kV, colour temperature 5700 K, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting electrically using 3-way 10 Amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm, 3-core from junction pole box to fitting complete all as specified and directed.. |
| 32 | Replacement of new generation LED Bollard 20W in cylindrical shape, energy saving, environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including fixing arrangement with base & connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed.Make: Havells / CG / Bajaj / Benlo / HPL or as approved. |
| 33 | Replacement of bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall and including 50 × 6 mm FI clamps – 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 34 | Replacement of automatic street light time switch 32 Amps, 3 pole, 230V Analog time switch for street lights/perimeter lights with complete fixing arrangement on wall/pole with nut, bolt, clamp and setting of timing of street light ON/OFF complete all as directed.Make: Conforming to Indo Asian Cat Part No. TL032AB0 or equivalent make Siemens/Benlo or as approved. |
| 35 | Replacement of Contactor MNX series of rating MNX-40 Amps for street light timer panel of following size (Make: L&T or equivalent as approved) in existing panel/location and connection including necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed. |
| 36 | Replacement of following items in the existing panels and connection with using aluminium lugs/ferrules including disconnection & connection of cable and making necessary alteration in panel/door using welding work and cutting as required for proper fixing & connection complete all as specified and directed as below:Note: Make of TPN MCB – Schneider / L&T / ABB / Legrand / Benlo |
| 37 | MCB TPN, 32 Amps, 415 Volt, ‘C’ Series, 10 kA |
| 38 | MCB TPN, 63 Amps, 415 Volt, ‘C’ Series, 10 kA |
| 39 | MCB SPN, 06–32 Amps, 240 Volt, ‘C’ Series, 10 kA |
| 40 | MCB SPN, 63 Amps, 240 Volt, ‘C’ Series, 10 kA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender