| 1 | M&L for, APP based polymeric membrane weighing minimum 3.5 Kg/Sqm and minimum 3 mm thick, reinforced with polyester non woven fabric( weight not less than 160 grams/Sqm) laid over primed surface including bitumens primer conforming to IS-3384 applied at rate of 0.3 litre/Sqm by forced application, complete all as specified and directed. Roof treatmentI roof shall consist of:- Note: The treatment shall be got executed through approved specialist agency or under their supervision and guidenceas under :- (i) 20 mm thick Cement plaster in CM 1:3 on fair faces of brick work or Concrete surfaces, Mixing with water proofing chemical (WPC will be measured and paid separetely) over neat cement slurry @200ml in each bag of cement of 50 kgs Kg/Sqm on old concrete Surfaces and taking down existing roof treatment including scrapping old bitumen layer complete of any description and removing of cement plaster/padding concrete on concrete surface of roof slab upto original roof slab including cleaning and disposal of debris off the premises complete all as directed.(ii) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3Litre/Sqm(iii) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over primer(vi) Laying of APP base membrane of specified thickness and weight by torch appliation and sealing joints(iv) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over APP based memebrane (vi) Applying two coats of bitumionous aluminium paint on top over APP based memebrane |
| 2 | M&L for, APP based polymeric membrane weighing minimum 3.5 Kg/Sqm and minimum 3 mm thick, reinforced with polyester non woven fabric( weight not less than 160 grams/Sqm) laid over primed surface including bitumens primer conforming to IS-3384 applied at rate of 0.3 litre/Sqm by forced application, complete all as specified and directed. Roof treatmentI roof shall consist of:- Note: The treatment shall be got executed through approved specialist agency or under their supervision and guidence as under :- (i) 20 mm thick Cement plaster in CM 1:3 on fair faces of brick work or Concrete surfaces, Mixing with water proofing chemical (WPC will be measured and paid separetely) over neat cement slurry @200ml in each bag of cement of 50 kgs Kg/Sqm on old concrete Surfaces and taking down existing roof treatment including scrapping old bitumen layer complete of any description and removing of cement plaster/padding concrete on concrete surface of roof slab upto original roof slab including cleaning and disposal of debris off the premises complete all as directed.(ii) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3Litre/Sqm(iii) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over primer(vi) Laying of APP base membrane of specified thickness and weight by torch appliation and sealing joints(iv) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over APP based memebrane (vi) Applying two coats of bitumionous aluminium paint on top over APP based memebrane(vii) Cement concrete tiles 25cm x 25 cm x 22mm thick machine pressed set jointed and pointed in neat cement slurry with grey cement and no pigment laid over APP based memebrane. |
| 3 | M&L for, PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in padding concrete/levelling course, to maintain slopes on roof and finishing the surfaces fair and even including necessary formwork and other similar work complete all as specified and directed. |
| 4 | M & L for preparation of concrete surfaces by brushing, cleaning and washing all the undulations, cracks, pores ,cleaned and sealed with PU sealant or crack seal properly and apply 1st coat of PU Magnum @ 750gram/Sqm over a coat of epoxy primer @ 200ml/sqm (laying 30-40 GSM Geotextile with 50mm side and end over laps on the layers wherever required and will be measured and paid seperately) and apply 2nd coat of PU Magnum on entire surface @750 grams/Sqm all as specified and as per manufacurers instructions and as direc tedBrand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge including 20 mm thick Cement plaster in CM 1:3 on fair faces of brick work or Concrete surfaces, Mixing with water proofing chemical (WPC will be measured and paid separetely) over neat cement slurry @200ml in each bag of cement of 50 kgs Kg/Sqm on old concrete Surfaces and taking down existing roof treatment including scrapping old bitumen layer complete of any description and removing of cement plaster/padding concrete on concrete surface of roof slab upto original roof slab including cleaning and disposal of debris off the premises complete all as directed. |
| 5 | Supply only Geotextile 30-40 GSM Complete all as per manufacturers instructions |
| 6 | Supply only Liquid water proofing chemical of pedelite/Doctor fixit or equallent (ISI Marked) complete,all as specified and directive. |
| 7 | M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizantal faces of grooves with cement mortar in CM 1:3 and making good in CM 1:3 after inserting membrance in to the groove. complete,all as specified and directive. |
| 8 | M & L, for PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate)as in roof kerbs or covering rounded or chamfered on edges all as specified. |
| 9 | M & L for Preparation of old plastered surfaces of External walls in different locations and at any height, contaminations, fungus and other micro organism growth shall be removed by mechanical means. Supply and applying Smartcare Damp proof single coats @ 0.45Ltr/Sqm over a coat of Damproof primer diluted with 33% by water and allow the coating to be cured complete as per manufacturer specifications. Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 10 | M & L for Preparation of old plastered surfaces of internal wall, in different locations and at any height, contaminations, fungus and other micro organism growth shall be removed by mechanical means. Supply and applying Damp block-2K two coats @ 1.50Kg/Sqm in two coats. Once the coating is cured, apply a single coat of epoxy triblock 1Kg/2 Sqm and allow the coating to be cured complete as per manufacturer specifications.Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 11 | M & L for all the visible cracks of external wall over 0.5mm size has to be cleaned properly & the same has to be cut open to 'V' grove with the help of machine and the same has to be filled with smartcare Hybrid PU sealant complete as per manufacturer recommendations. Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 12 | S&F, Roof trusses (framed), trussed, purlins, crane gantries rails and fastenings and heavy bracket framing of any section (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe 290W (Grade E-165) quality 'A' , including Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | S&F in repair, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified directive. |
| 14 | S&F in repair, Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws as specified, complete all as specified and directed. |
| 15 | S&F in repair, 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc., complete all as specified and directed. |
| 16 | M&L for Preparation of new surfaces of steel and iron/steel surfaces and applying two coats of first qualtiy synthetic enamel paint over a coat of primer, complete all as specified and directed. |
| 17 | M & L for cutting of bushes small trees (Peepal small plants or any other plant etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site and as directed by Engr-in-Charge |
| 18 | Disconnecting existing tanks of capacity exceeding 250 litres and not exceeding 500 litres setting aside (or lowering if required) for repairs, to make convinient for roof treatment cleaning and removing all scale and dirt etc., from tanks and from mouths of circulating pipes and hoisting as required, reconnecting and refixing in position complete all as directed. |
| 19 | Disconnecting existing tanks of capacity exceeding 500 litres and not exceeding 1000 litres setting aside (or lowering if required) for repairs,to make convinient for roof treatment cleaning and removing all scale and dirt etc., from tanks and from mouths of circulating pipes and hoisting as required, reconnecting and refixing in position complete all as directed. |
| 20 | S&F in repairs, 500 litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed. |
| 21 | S&F in repairs, 1000 litres capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including connecting up of existing inlet and outlet pipes and ball valve complete all as specified and as directed. |
| 22 | S&F, 20mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed. |
| 23 | S&F 25mm bore premium PTMT Ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball and fly nut complete, screwed for iron/GI pipe or brass ferrule complete all as specified and directed. |
| 24 | S&F in repairs, 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 will all necessary fittings on walls/ceiling or laying in floors complete all as specified. complete all as specified and directed. |
| 25 | S&F in repairs, 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 will all necessary fittings on walls/ceiling or laying in floors complete all as specified. complete all as specified and directed. |
| 26 | S&F in repairs, 15mm bore steel water tubing, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls, ducts/ceilings or laid in floors complete all as specified and directed. |
| 27 | All as per item No 26 above but 20mm bore of pipe. |
| 28 | S&F, 75mm dia PVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete including removing all loose packed plaster/cement mortar around the pvc pipe, making good and water tightened around the pipe and making proper slope to troughed portion using cement mortar 1:2(using water proofing liquid) to flow water into the PVC rainwater pipe properly from roof including taking down rainwater pipes (any size or pattern) fixed to walls, including all fittings, heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories), all as specified and as directed. |
| 29 | S&F, 110mm dia PVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete including removing all loose packed plaster/cement mortar around the pvc pipe, making good and water tightened around the pipe and making proper slope to troughed portion using cement mortar 1:2(using water proofing liquid) to flow water into the PVC rainwater pipe properly from roof, including taking down rainwater pipes (any size or pattern) fixed to walls, including all fittings, heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories), all as specified and as directed.all as specified and as directed. |
| 30 | S&F, 75mm bore PVC(SWR) bends any radius with access door complete all as specified and as directed. |
| 31 | S&F, 110mm bore PVC(SWR) bends any radius with access door complete all as specified and as directed. |
| 32 | M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) including demolition of brick built in cement mortar of any description complete all as specified. |
| 33 | M & L for 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and smooth withou using extra cement complete all as specified & directed. |
| 34 | M & L for 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. |
| 35 | M & L for 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and fair including taking down cement or cement lime plaster on brick or stone walls complete all as specified & directed. |
| 36 | M&L for preparation , new plastered surfaces of walls and applying two at of exterior acrylic emulsion paint (Finished coat) including removing existing nails if any, in any numbrs and filling the disturbed/ uneven surfaces, holes/voids with wall care putty/POP/white cement where ever necessary to achieve the smooth surface complete all as specified and directed. |
| 37 | M&L for preparation , removing/scrapping down existing surfaces of old plastered or unplastered surfaces of walls and applying two coat of exterior acrylic emulsion paint (Finished coat) including removing existing nails if any, in any numbrs and filling the disturbed/ uneven surfaces, holes/voids with wall care putty/POP/white cement where ever necessary to achieve the smooth surface complete all as specified and directed. |
| 38 | Material & labour for sunken slab treatment comprising of the following :-(a) Taking out/ down old existing sunken slab treatment and cleaning the old RCC surfaces of sunken slab including removal of the rubbish from the site of work to a distance n.exc. 250mm compete all as specified and directed.(b) Material & labour for 50mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) over cleaned sunken slab surfaces.(c) Material & labour for applying bituminous priming coat/tack coat over PCC surfaces @ 0.30 Kg per square metre of surfaces. (d) Material & labour for applying bitumin grade 85/25 over priming coat @ 1.20 Kg per Square metre. (e) Material & labour for 25mm thick plastering in CM 1:4 using water proofing compound (WPC) @ 3% by weight of cement. on wall of sunken floor (f) Material & labour for suitable thickness of PCC 1:5:10 type E-2 (using 40mm graded broken brick aggregate) for filling in the sunken portion of slab up to its floor level.(g) Supply & fix of 32mm dia GI pipe medium grade, 450m long (for draining out the water) all as directed by engineer-in-Charge |
| 39 | M&L, for 7 to 8mm thick coloured, joint free Non skid ceramic tiles of size 400 x 400mm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in cement mortar 1:4, including 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring, finishing the surface even and smooth using extra cement including necessary formwork and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed.Note: Shade and design/pattern of tiles shall be as directed by GE. |
| 40 | M&L, for coloured glazed ceramic tiles of size 300 x 450mm, 6 to 7mm thick in dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick backing coat in CM 1:3, including dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed. Note: Shade and design/pattern of tiles shall be as directed by GE. |
| 41 | Supply and fixing in repair vitreous china squatting pan white orissa pattern size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron P trap including lime concrete bedding and making good the disturbed portion to match with the existing surface of floor complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fixing in repair PVC valveless, syphonic action type, flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC bend including connection to IWC/EWC and fixing on wall with brackets complete all as specified and directed by Engr-in-charge. |
| 43 | Supply and fixing PVC connections 15mm bore, 450 mm length with PTMT nuts complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |