Tender For Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysyte
Tender Overview
Project Description
Tender for Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysytem And Replacement Of Mcbs, Dbs, Repair Of Ceiling/Exhaust Fans & Other Allied Works Of Restricted Area Of Cod And 506 Abw Under Ge (East) Jabalpur
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing in Replacement of switch piano flush button single pole one way, 6 Amps, 240 V for attending day to day complaint including taking down old one complete all as directed. |
| 2 | Supply and fixing in Replacement of bell push piano flush type 6 amps , 240 V for attending day to day complaint including taking down old one complete all as directed. |
| 3 | Supply and fixing in Replacement of buzzer door bell, AC 230 volts Single Phase attending day to day complaint including taking down old one complete all as directed. |
| 4 | Supply and fixing in Replacement of socket outlet 2-in-1 3 pin, 6 Amps flush type for day to day complaint complete including taking down old one complete all as directed. |
| 5 | Supply and fixing in Replacement of Switch socket combination 2-in-1 3 pin 6 Amps flush type for day to day complaint including taking down old one complete all as directed. |
| 6 | Supply and fixing in replacement of Switch piano flush button single pole one way, 16 Amps, 230/240 V for day to day complaint including taking down old one complete all as directed. |
| 7 | Supply and fixing in Replacement of Socket outlet 2-in-1 3 pin, 6 & 16 Amps flush type for day to day complaint including taking down old one complete all as directed. |
| 8 | Supply and fixing in Replacement of Switch socket combination 3 pin , 6A and 16 Amps flush type universal for day to day complaint including taking down old one complete all as directed. |
| 9 | Supply and fixing in Replacement of Fan regulator socket type stepped type (electronic ) 1200/1400mm sweep AC ceiling fan for day to day complaint including taking down old one complete all as directed. |
| 10 | Supply and fixing in Replacement of modular type switch, one way 6 Amps , 1 module for day to day complaint all including taking down old one complete all as directed. |
| 11 | Supply and fixing in Replacement of modular type socket 3 pin, 6 Amps, combined 2 module for day to day complaint complete including taking down old one complete all as directed. |
| 12 | Supply and fixing in Replacement of modular type socket 3 pin, 6 /16 Amps combined 2 module for day to day complaint including taking down old one complete all as directed. |
| 13 | Supply and fixing in Replacement of modular type switch, one way 16 Amps, 1 module for day to day complaint including taking down old one complete all as directed. |
| 14 | Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 6 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed. |
| 15 | Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed. |
| 16 | Supply and fixing in replacement of metalic plug top 3 pin with easy grip white matte finish tested as per IS 1293, 15/16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed. |
| 17 | Supply and fixing in Replacement of fan capacitor 2.15 mfd to 2.5 mfd for day to day complaint including taking down old one complete all as directed. |
| 18 | Material and labour in Replacement of modular sheet cover plate with frame of size 16 module for day to day complaint including taking down old one complete all as directed. |
| 19 | Material and labour in Replacement of modular sheet cover plate with frame of size 12 module for day to day complaint including taking down old one complete all as directed. |
| 20 | Material and labour in Replacement of modular sheet cover plate with frame of size 8 module for day to day complaint including taking down old one complete all as directed. |
| 21 | Material and labour in Replacement of modular sheet cover plate with frame of size 6 module for day to day complaint including taking down old one complete all as directed. |
| 22 | Material and labour in Replacement of modular sheet cover plate with frame of size 4 module for day to day complaint including taking down old one complete all as directed. |
| 23 | Material and labour in Replacement of modular sheet cover plate with frame of size 3 module for day to day complaint including taking down old one complete all as directed. |
| 24 | Material and labour in Replacement of modular sheet cover plate with frame of size 2 module for day to day complaint including taking down old one complete all as directed. |
| 25 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 16 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 26 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 12 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 27 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 8 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 28 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 6 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 29 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 4 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 30 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 3 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 31 | Material and labour in Replacement of GI/pressed steel terminal switch board of size 2 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed. |
| 32 | S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed. |
| 33 | S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175 mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed. |
| 34 | S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep for day to day complaint including taking down old one complete all as directed. |
| 35 | S&F in replacement of 3 mm thick Hylam sheet of size 300mm x 250mm including brass screws and washers etc as per required at site complete all as specified and as directed. |
| 36 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed. |
| 37 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 16 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed. |
| 38 | Note : The contractor shall attend to the office of Engr-in-Charge daily in persion or through his authorised representative with necessary T&P and collect the day to day complaint with respect to the area of contract against Item No. 1 to 29 and deposite the complent slip to complent cell after complete the work with user signature. |
| 39 | Taking down carefully copper/aluminium point wiring ( light,fan,power point or bell point etc) complete including fixture and fitting such as switches,ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 40 | Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 41 | Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe custody or for taking credit(credit for above items should be made as per condition seaparately) and making godd to the disturbed surface etc complete all as specified and directed. |
| 42 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for One light point controlled by one switch 5/6 Amps. |
| 43 | ditto as per item No. 42 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps. |
| 44 | ditto as per item No. 42 but for one Bell Point controlled by one switch 5/6 Amps on independent/same board. |
| 45 | ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on same board. |
| 46 | ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on Independent board. |
| 47 | ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on Independent but below the switch board of light points in the same vertical plane. |
| 48 | ditto as per item No. 42 but for one light point controlled by two way switch 5/6 Amps. |
| 49 | All as per item No. 33 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge. |
| 50 | Material & Labour for point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn through existing concealed/open PVC conduits medium grade not less than 20mm( ISI marked) and including PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch 5/6 Amps. |
| 51 | ditto as per item No. 50 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps. |
| 52 | ditto as per item No. 50 but for one Bell Point controlled by one switch 5/6 Amps. |
| 53 | ditto as per item No. 50 but for one socket point 5 Amp controlled by one switch on same board. |
| 54 | ditto as per item No. 50 but for one socket point 5 Amp controlled by one switch on Independent board. |
| 55 | ditto as per item No. 50 but for one light point controlled by two way switch 5/6 Amps. |
| 56 | All as per item No. 50 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge. |
| 57 | M&L point wiring with FRLS PVC insulated unsheathed multistranded copper conductor,conforming to IS-694 of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20 mm size 'medium grade' PVC doubled lock Casing-Capping/PVC conduit and fittings, including, pressed steel concealed terminal switch boxes not less than 1.2mm thick of reqd size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories and making good the disturbed surfaces and match with the existing surfaces complete all as specified and directed for One light Point controlled by one switch 5/6 Amps. |
| 58 | ditto as per item No. 57 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps. |
| 59 | ditto as per item No. 57 but for one Bell Point controlled by one switch. |
| 60 | ditto as per item No. 57 but for one socket point 5 Amp controlled by one switch on same board. |
| 61 | ditto as per item No. 57 but for one socket point 5 Amp controlled by one switch on Independent board. |
| 62 | ditto as per item No. 57 but for one light point controlled by two way switch. |
| 63 | All as per item No. 57 here in above but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete. |
| 64 | S & F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed. |
| 65 | S & F bell push flush type 5 Amp complete all as specified and directed |
| 66 | S & F switch piano flush type 15 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed. |
| 67 | S & F 5 pin socket outlet, 5/6 Amps / 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed |
| 68 | S & F switch socket combination 2 in 1, 3 Pin, 5 A flush type , ISI marked, complete all as specified and directed |
| 69 | S & F switch socket combination 2 in 1, 3 Pin, 15 A flush type universal, ISI marked, complete all as specified and directed |
| 70 | S & F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed. |
| 71 | S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified & directed. |
| 72 | S & F for modular Switch, single pole, one way and 5/6 Amp, single modular complete all as specified and directed |
| 73 | S & F for modular Switch, single pole, one way and 15/16 Amp, single modular complete all as specified and directed |
| 74 | S & F for Bell push modular 6 Amps single module complete all as specified and directed. |
| 75 | S & F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amps and 2 pin, 5/6 Amp, 2 module type complete complete all as specified and directed |
| 76 | S & F modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amps and 3 pin, 5/6 Amp, 2 module type complete complete all as specified and directed |
| 77 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed. |
| 78 | S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified & directed. |
| 79 | S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc, complete all as specified & directed. |
| 80 | S&F modular cover plate 1 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 81 | S&F modular cover plate 2 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 82 | S&F modular cover plate 3 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 83 | S&F modular cover plate 4 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 84 | S&F modular cover plate 6 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 85 | S&F of modular cover plate 8 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 86 | S&F modular cover plate 12 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 87 | S&F modular cover plate 16 module including screws and washers etc model/make as per existing at site complete all as specified and as directed. |
| 88 | S & F Metal flush box 1/2 module complete all as specified and directed. |
| 89 | Ditto as per item No. 88 but 3 module complete all as specified and directed |
| 90 | Ditto as per item No. 88 but 4 module complete all as specified and directed |
| 91 | Ditto as per item No. 88 but 6 module complete all as specified and directed |
| 92 | Ditto as per item No. 88 but 8 module complete all as specified and directed |
| 93 | Ditto as per item No. 88 but 12 module complete all as specified and directed |
| 94 | Ditto as per item No. 88 but 16 module complete all as specified and directed |
| 95 | S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed. |
| 96 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note :- Four runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run ( with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 97 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2x 10.0 sq. mm + 1 x 10.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 10 Sqmm cable, one run ( with Green colour for Earth) of 10 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 98 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 99 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 100 | S&F in replacement LED Bulb 5 star rating, 230V AC 12 watt warm/cool day light 6500K as per the direction/requirement of site complere all as specified and directed by Engineer-in -charge. |
| 101 | S & F in replacement LED 9W bulkhead with IP66 protection and IK09 impact resistance suitable surface/wall mounting applications including connecting up with three core flexible copper conductor cable of suitable size from ceilig rose comnplete all as specified and directed. |
| 102 | S & F in replacement round shape 12 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specefied and directed. |
| 103 | S&F in replacement IP 20, Class I, LED Mirror light fitting10 W, (or nearest next higher wattage) min 120 LM/watt, natural white(4000K)/ cool white (6500k), wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified. |
| 104 | S&F in replacement IP 20, Class I, Smart bright Batten Series, LED luminaire using LEDs 20 watt min 120 LM/watt, natural white(4000K)/ cool white (6500k), with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall/ceiling mounting fixed with 02 Nos of PVC round/ square blocks, screws etc(supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification. |
| 105 | S & F in replacement LED luminaire cool day light/warm white as required of size 1'x4' rectangular LED panel 35/36 watts, 220V recessed/Surface mounted type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed. |
| 106 | S & F in replacement LED luminaire cool day/warm white as required 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed/surface type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed. |
| 107 | Supply & fix in replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint, including pvc flexible hose pipe as per required length. complete all as specified and as directed. |
| 108 | S&F in replacement decorative wall light fitting made up of Polycarbonate ,Cylindrical shape or as per the sample required/obtained from the site and mounting arrangement to fix the lamp and all as directed by Engr-in-Charge with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. |
| 109 | S & F in replacement sheet metal enclosure MCCB DB VTPN 4 Way vertical type 250 A Copper Busbar for each phase Fully insulated busbar & shrouded Neutral bars with provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing Reversible Door for IP 43 IK-09 DB's system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 110 | S & F in replacement sheet metal enclosure MCB DB TPN 4 Way type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 111 | S & F in replacement sheet metal enclosure MCB DB SPN 12 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 112 | S & F in replacement sheet metal enclosure MCB DB SPN 8 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 113 | S & F in replacement sheet metal enclosure MCB DB SPN 4 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 114 | S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20A, 10 KA 240 volt and including necessary provision for inserting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directedcomplete all as specified and as directed. |
| 115 | S & F in replacement MCB triple Pole and neutral rated capacity 63 Amps, 415 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed. |
| 116 | S & F in replacement MCB single Pole and neutral rated capacity 40-63 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed. |
| 117 | S & F in replacement MCB single Pole and neutral rated capacity 32 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed. |
| 118 | S & F in replacement MCB single Pole and neutral rated capacity 6 to 32 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed. |
| 119 | M & L in replacement of electronic LED driver 36 Watt for panel type fitting of suitable size as per existing model complete all as specified. |
| 120 | M & L in replacement of LED driver 20W fitting of suitable size as per existing model complete. |
| 121 | M & L in replacement of three core flexible wire 1.0 Sqmm for connecting up ceiling fans , exhaust fans/wall mounting fan etc. |
| 122 | Taking down ceiling fan sealing cable end, dismantling blades and removing fan and blades to store for repair work complete all as specified and directed. |
| 123 | Taking down exhaust fan sealing cable end, dismantling blades and motor removing blades and motor to store for repair work including re-fixing at same location complete all as specified by Engr in charge Please Enable Macros to View BoQ information |
| 124 | Taking down exhaust fan sealing cable end, dismantling blades and motor removing blades and motor to store for repair work including re-fixing at same location complete all as specified by Engr in charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender