Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56175794

Tender For Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysyte

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
1.10 Crore
Estimated cost
Bid Submission
23 Jul 2026
14 days left
EMD
1.85 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysytem And Replacement Of Mcbs, Dbs, Repair Of Ceiling/Exhaust Fans & Other Allied Works Of Restricted Area Of Cod And 506 Abw Under Ge (East) Jabalpur

BOQ

Name of Work:- COMPREHENSIVE DAY TO DAY MAINTENANCE/REPAIR/REWIRING AS APPLICABLE FOR INTERNAL ELECTRIFICATION AND WINTER APPLIANCES SUCH AS INTERNAL LIGHT FITTINGS & FIXTURES, POINT WIRING, SUBMAIN WIRING, FLAMEPROOF WIRING, LIGHTENING PROTECTION SYSYTEM AND REPLACEMENT OF MCBS, DBS, REPAIR OF CEILING/EXHAUST FANS & OTHER ALLIED WORKS OF RESTRICTED AREA OF COD AND 506 ABW UNDER GE (EAST) JABALPUR
Sl. No. Item Description
1Supply and fixing in Replacement of switch piano flush button single pole one way, 6 Amps, 240 V for attending day to day complaint including taking down old one complete all as directed.
2Supply and fixing in Replacement of bell push piano flush type 6 amps , 240 V for attending day to day complaint including taking down old one complete all as directed.
3Supply and fixing in Replacement of buzzer door bell, AC 230 volts Single Phase attending day to day complaint including taking down old one complete all as directed.
4Supply and fixing in Replacement of socket outlet 2-in-1 3 pin, 6 Amps flush type for day to day complaint complete including taking down old one complete all as directed.
5Supply and fixing in Replacement of Switch socket combination 2-in-1 3 pin 6 Amps flush type for day to day complaint including taking down old one complete all as directed.
6Supply and fixing in replacement of Switch piano flush button single pole one way, 16 Amps, 230/240 V for day to day complaint including taking down old one complete all as directed.
7Supply and fixing in Replacement of Socket outlet 2-in-1 3 pin, 6 & 16 Amps flush type for day to day complaint including taking down old one complete all as directed.
8Supply and fixing in Replacement of Switch socket combination 3 pin , 6A and 16 Amps flush type universal for day to day complaint including taking down old one complete all as directed.
9Supply and fixing in Replacement of Fan regulator socket type stepped type (electronic ) 1200/1400mm sweep AC ceiling fan for day to day complaint including taking down old one complete all as directed.
10Supply and fixing in Replacement of modular type switch, one way 6 Amps , 1 module for day to day complaint all including taking down old one complete all as directed.
11Supply and fixing in Replacement of modular type socket 3 pin, 6 Amps, combined 2 module for day to day complaint complete including taking down old one complete all as directed.
12Supply and fixing in Replacement of modular type socket 3 pin, 6 /16 Amps combined 2 module for day to day complaint including taking down old one complete all as directed.
13Supply and fixing in Replacement of modular type switch, one way 16 Amps, 1 module for day to day complaint including taking down old one complete all as directed.
14Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 6 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
15Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
16Supply and fixing in replacement of metalic plug top 3 pin with easy grip white matte finish tested as per IS 1293, 15/16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
17Supply and fixing in Replacement of fan capacitor 2.15 mfd to 2.5 mfd for day to day complaint including taking down old one complete all as directed.
18Material and labour in Replacement of modular sheet cover plate with frame of size 16 module for day to day complaint including taking down old one complete all as directed.
19Material and labour in Replacement of modular sheet cover plate with frame of size 12 module for day to day complaint including taking down old one complete all as directed.
20Material and labour in Replacement of modular sheet cover plate with frame of size 8 module for day to day complaint including taking down old one complete all as directed.
21Material and labour in Replacement of modular sheet cover plate with frame of size 6 module for day to day complaint including taking down old one complete all as directed.
22Material and labour in Replacement of modular sheet cover plate with frame of size 4 module for day to day complaint including taking down old one complete all as directed.
23Material and labour in Replacement of modular sheet cover plate with frame of size 3 module for day to day complaint including taking down old one complete all as directed.
24Material and labour in Replacement of modular sheet cover plate with frame of size 2 module for day to day complaint including taking down old one complete all as directed.
25Material and labour in Replacement of GI/pressed steel terminal switch board of size 16 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
26Material and labour in Replacement of GI/pressed steel terminal switch board of size 12 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
27Material and labour in Replacement of GI/pressed steel terminal switch board of size 8 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
28Material and labour in Replacement of GI/pressed steel terminal switch board of size 6 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
29Material and labour in Replacement of GI/pressed steel terminal switch board of size 4 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
30Material and labour in Replacement of GI/pressed steel terminal switch board of size 3 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
31Material and labour in Replacement of GI/pressed steel terminal switch board of size 2 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
32S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed.
33S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175 mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed.
34S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep for day to day complaint including taking down old one complete all as directed.
35S&F in replacement of 3 mm thick Hylam sheet of size 300mm x 250mm including brass screws and washers etc as per required at site complete all as specified and as directed.
36S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed.
37S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 16 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed.
38Note : The contractor shall attend to the office of Engr-in-Charge daily in persion or through his authorised representative with necessary T&P and collect the day to day complaint with respect to the area of contract against Item No. 1 to 29 and deposite the complent slip to complent cell after complete the work with user signature.
39Taking down carefully copper/aluminium point wiring ( light,fan,power point or bell point etc) complete including fixture and fitting such as switches,ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
40Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
41Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe custody or for taking credit(credit for above items should be made as per condition seaparately) and making godd to the disturbed surface etc complete all as specified and directed.
42M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for One light point controlled by one switch 5/6 Amps.
43ditto as per item No. 42 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
44ditto as per item No. 42 but for one Bell Point controlled by one switch 5/6 Amps on independent/same board.
45ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on same board.
46ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on Independent board.
47ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on Independent but below the switch board of light points in the same vertical plane.
48ditto as per item No. 42 but for one light point controlled by two way switch 5/6 Amps.
49All as per item No. 33 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
50Material & Labour for point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn through existing concealed/open PVC conduits medium grade not less than 20mm( ISI marked) and including PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch 5/6 Amps.
51ditto as per item No. 50 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
52ditto as per item No. 50 but for one Bell Point controlled by one switch 5/6 Amps.
53ditto as per item No. 50 but for one socket point 5 Amp controlled by one switch on same board.
54ditto as per item No. 50 but for one socket point 5 Amp controlled by one switch on Independent board.
55ditto as per item No. 50 but for one light point controlled by two way switch 5/6 Amps.
56All as per item No. 50 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
57M&L point wiring with FRLS PVC insulated unsheathed multistranded copper conductor,conforming to IS-694 of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20 mm size 'medium grade' PVC doubled lock Casing-Capping/PVC conduit and fittings, including, pressed steel concealed terminal switch boxes not less than 1.2mm thick of reqd size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories and making good the disturbed surfaces and match with the existing surfaces complete all as specified and directed for One light Point controlled by one switch 5/6 Amps.
58ditto as per item No. 57 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
59ditto as per item No. 57 but for one Bell Point controlled by one switch.
60ditto as per item No. 57 but for one socket point 5 Amp controlled by one switch on same board.
61ditto as per item No. 57 but for one socket point 5 Amp controlled by one switch on Independent board.
62ditto as per item No. 57 but for one light point controlled by two way switch.
63All as per item No. 57 here in above but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
64S & F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
65S & F bell push flush type 5 Amp complete all as specified and directed
66S & F switch piano flush type 15 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
67S & F 5 pin socket outlet, 5/6 Amps / 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed
68S & F switch socket combination 2 in 1, 3 Pin, 5 A flush type , ISI marked, complete all as specified and directed
69S & F switch socket combination 2 in 1, 3 Pin, 15 A flush type universal, ISI marked, complete all as specified and directed
70S & F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
71S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified & directed.
72S & F for modular Switch, single pole, one way and 5/6 Amp, single modular complete all as specified and directed
73S & F for modular Switch, single pole, one way and 15/16 Amp, single modular complete all as specified and directed
74S & F for Bell push modular 6 Amps single module complete all as specified and directed.
75S & F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amps and 2 pin, 5/6 Amp, 2 module type complete complete all as specified and directed
76S & F modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amps and 3 pin, 5/6 Amp, 2 module type complete complete all as specified and directed
77S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
78S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified & directed.
79S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc, complete all as specified & directed.
80S&F modular cover plate 1 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
81S&F modular cover plate 2 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
82S&F modular cover plate 3 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
83S&F modular cover plate 4 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
84S&F modular cover plate 6 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
85S&F of modular cover plate 8 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
86S&F modular cover plate 12 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
87S&F modular cover plate 16 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
88S & F Metal flush box 1/2 module complete all as specified and directed.
89Ditto as per item No. 88 but 3 module complete all as specified and directed
90Ditto as per item No. 88 but 4 module complete all as specified and directed
91Ditto as per item No. 88 but 6 module complete all as specified and directed
92Ditto as per item No. 88 but 8 module complete all as specified and directed
93Ditto as per item No. 88 but 12 module complete all as specified and directed
94Ditto as per item No. 88 but 16 module complete all as specified and directed
95S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
96Material and labour for concealed sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note :- Four runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run ( with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit.
97Material and labour for concealed sub-main wiring alongwith earth wire of size of 2x 10.0 sq. mm + 1 x 10.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 10 Sqmm cable, one run ( with Green colour for Earth) of 10 Sqmm cable and one run of PVC conduit will be measured as one unit.
98Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
99Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
100S&F in replacement LED Bulb 5 star rating, 230V AC 12 watt warm/cool day light 6500K as per the direction/requirement of site complere all as specified and directed by Engineer-in -charge.
101S & F in replacement LED 9W bulkhead with IP66 protection and IK09 impact resistance suitable surface/wall mounting applications including connecting up with three core flexible copper conductor cable of suitable size from ceilig rose comnplete all as specified and directed.
102S & F in replacement round shape 12 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specefied and directed.
103S&F in replacement IP 20, Class I, LED Mirror light fitting10 W, (or nearest next higher wattage) min 120 LM/watt, natural white(4000K)/ cool white (6500k), wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified.
104S&F in replacement IP 20, Class I, Smart bright Batten Series, LED luminaire using LEDs 20 watt min 120 LM/watt, natural white(4000K)/ cool white (6500k), with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall/ceiling mounting fixed with 02 Nos of PVC round/ square blocks, screws etc(supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification.
105S & F in replacement LED luminaire cool day light/warm white as required of size 1'x4' rectangular LED panel 35/36 watts, 220V recessed/Surface mounted type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
106S & F in replacement LED luminaire cool day/warm white as required 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed/surface type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
107Supply & fix in replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint, including pvc flexible hose pipe as per required length. complete all as specified and as directed.
108S&F in replacement decorative wall light fitting made up of Polycarbonate ,Cylindrical shape or as per the sample required/obtained from the site and mounting arrangement to fix the lamp and all as directed by Engr-in-Charge with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed.
109S & F in replacement sheet metal enclosure MCCB DB VTPN 4 Way vertical type 250 A Copper Busbar for each phase Fully insulated busbar & shrouded Neutral bars with provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing Reversible Door for IP 43 IK-09 DB's system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
110S & F in replacement sheet metal enclosure MCB DB TPN 4 Way type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
111S & F in replacement sheet metal enclosure MCB DB SPN 12 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
112S & F in replacement sheet metal enclosure MCB DB SPN 8 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
113S & F in replacement sheet metal enclosure MCB DB SPN 4 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
114S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20A, 10 KA 240 volt and including necessary provision for inserting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directedcomplete all as specified and as directed.
115S & F in replacement MCB triple Pole and neutral rated capacity 63 Amps, 415 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
116S & F in replacement MCB single Pole and neutral rated capacity 40-63 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
117S & F in replacement MCB single Pole and neutral rated capacity 32 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
118S & F in replacement MCB single Pole and neutral rated capacity 6 to 32 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
119M & L in replacement of electronic LED driver 36 Watt for panel type fitting of suitable size as per existing model complete all as specified.
120M & L in replacement of LED driver 20W fitting of suitable size as per existing model complete.
121M & L in replacement of three core flexible wire 1.0 Sqmm for connecting up ceiling fans , exhaust fans/wall mounting fan etc.
122Taking down ceiling fan sealing cable end, dismantling blades and removing fan and blades to store for repair work complete all as specified and directed.
123Taking down exhaust fan sealing cable end, dismantling blades and motor removing blades and motor to store for repair work including re-fixing at same location complete all as specified by Engr in charge Please Enable Macros to View BoQ information
124Taking down exhaust fan sealing cable end, dismantling blades and motor removing blades and motor to store for repair work including re-fixing at same location complete all as specified by Engr in charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56175794
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.10 Crore
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysytem And Replacement Of Mcbs, Dbs, Repair Of Ceiling/Exhaust Fans & Other Allied Works Of Restricted Area Of Cod And 506 Abw Under Ge (East) Jabalpur
Basic Detail
Tender No 82765/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 25 Jun 2026
Submission Date 23 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 1.10 Crore
Tender Fee 1000
EMD 1.85 Lakhs
Exemption Available
Document List
BOQ_867581.xls
dea27da1-f141-487d-8403-b1d2d2c83d9c.html
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_867581.xls

html

dea27da1-f141-487d-8403-b1d2d2c83d9c.html

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders