| 1 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 3 | Use and waste of form work to sides of concrete foundations, footings, base of columns, sides and soffits of plinth beams, sides of pile caps and similar work for rough finished surface of concrete complete all as specified and directed. |
| 4 | M&L for Reinforced cement concrete M-30 (design Mix), using 20 mm graded stone aggregate) in foundation including rafts ,footing ,foundation beams , plinth beams, bases for columns etc, pile and mass, complete all as specified and directed. |
| 5 | Use and waste form work to sides pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and as directed. |
| 6 | M&L for RCC M-30 (design Mix) using 20 mm graded stone aggregate) for columns, pillars, piers, posts and struts complete all as specified and directed. |
| 7 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves ,plinth beam including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 8 | M&L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span etc.complete all as specified and directed |
| 9 | Use and waste of form work to soffits of suspended slabs such as roof slabs, n. exc. 20cm thick (horizontal or sloping for fair finished concrete surface complete all as specified and directed. |
| 10 | M&L for RCC M-30 (Design mix) using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the like etc complete all as specified and directed. |
| 11 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide flat fair finished surface complete all as specified and directed. |
| 12 | S & F high strength corrosion resistant TMT bars of grade Fe 500D 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | S & F high strength corrosion resistant TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 14 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 15 | M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed. |
| 16 | M&L for 10 mm thick rendering in CM 1:6 on fair face of brick work finish the surface fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 17 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on other than fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 18 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 19 | M&L for preparation of new platered surface of wall and applying two coats of weather proof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre, dart pick up resistant,silicon enhanced,UV resistant and PU enhanced property over a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces including all necessary scaffolding,complete all as specified and directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 20 | Material and labour for preparing newly plastered surfaces of internal walls, etc and applying two coats of acrylic/ oil bound washable distemper over a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. Note :- (a) Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS (b) Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer) |
| 21 | M & L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed |
| 22 | M & L for 10 mm thick, screed bed as in roof in cement mortar 1:3 finishing the surfaces even and smooth without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately) |
| 23 | Material and labour for preparation of horizontal or vertical surfaces for water proofing treatment on existing cleaned non accessible RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and cleaning of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer(85/25 grade)conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps shall be applied on the prepared surface.(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane. |
| 24 | Supply, laying, connection and testing, 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 25 | Supply, laying, connection and testing in repair, 40 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 26 | S & F vitreous China wash down water closet pan (pedestal pattern) of size 560mm x 440 mm x 395 mm, white, including connection to outgoing drain and flushing pipe, P/S trap, anti syphonic pipe and seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/ disturbed surfaces complete all as specified and directed. |
| 27 | S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 28 | Suppy and fixing looking mirror with frame of size 600 mm x 450mm x 6 mm of selected quality Belgium glass and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. Make: Prayag Cat No. BLM-01F or equivelant of make as per List of manufacturer as mentioned in PS. |
| 29 | S & F 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed. |
| 30 | S & F 15mm bore, two Way Bib Cock with Wall Flange cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 31 | S&F 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type, screwed for iron pipe or for brass ferrule complete |
| 32 | S & F 15 mm bore, Stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 33 | S & F 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed. |
| 34 | S&F vitreous China wash hand basin table top thin rim white coloured, rectangular shape, of size : 495x395x150 mm including cutting for and pinning in ends of brackets or making suitable size of hole for pillar tap in RCC slab and granite hole complete all as specified and directed Make: Jaquar Cat No. JDS-WHT-25909 or equivelant of make as per List of manufacturer's |
| 35 | S & F 15 mm bore, pillar taps, single lever tall Boy with 150mm extension body fixed spout without popup waste system with 600mm long braided hoses complete all as specified and directed. Make : Jaquar Cat No.FLR-5005NB or equivelant of make as per list of manufacturer's |
| 36 | S & F hand wash dispencer holder, fixed in walls with plugs & chromium plated brass screws complete all as specified and directed. Make: Jaquar Cat No. SDR-WHT-DJ0010FN or equivelant model of make as per list of manufacturer mentioned in PS. |
| 37 | S&F Automatic sensor based hand dryers with stainless steel metal finish surface complete all as specified and as directed. Make : Jaquar Cat No. HDR-SSF-AK2807 or equivalent model of make mention in PS |
| 38 | S & F Toilet Roll Holder with Stainless Steel Flap, fixed to wall with brass screw complete all as specified and directed (Make: Jaquar Cat No. ACN-1153S or equivelant of make as per List of manufacturer's) |
| 39 | S & F 15 mm bore, CP Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. (Make: Jaquar Cat No. ALD-573 or equivelant of make as per List of manufacturer's) |
| 40 | M & L for granite stone slab (of any type) 18 to 20 mm thick (Table rubbed and polished), machine cut, colour Mexican Red/Ruby Red/Z black/Paerl black etc design/pattern as directed including inlays, borders, margins in two or more colours/shades as in floors, trades of steps, cill cooking platform etc set and bedded and jointed with grey cement slurry and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite slabs including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 41 | Providing and fixing factory made uPVC white colour fixed window/ventilator (half fixed half louvered) made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners including stainless steel wire cloth ,0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless stell wire staple complete all as specified and as directed. |
| 42 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum comp?ressive strength of58N/mm2,modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property ofbeingtermite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs /SS dash fasteners shall be paid for separetly complete all as specified and directed. |
| 43 | S & F 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive trength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body hreaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges with S S screws shall be paid separately) complete all as specified and directed. |
| 44 | S&F 200 mm long, Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts complete all as specified and directed. |
| 45 | S&F 100 mm long medium weight,stainless steel butt hinges complete all as specified and directed. |
| 46 | S & F 150 mm size, designer Brass handles, cast type, polished bright complete all as specified and directed. |
| 47 | S & F 300mm long, Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 48 | M&L for Non-skid light coloured ceramic joint free tiles with tile spacer of minimum 3 mm thickness & in light shade 7 to 8mm thick , area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm in floors set and jointed with epoxy grout and masking tape and pointed in white cement or white cement mixed with colour pigment to match the shade of the tile including 15 mm thick screed bed in cement mortor 1:6 a complete all as specified and directed. |
| 49 | M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/ 300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick backing coat in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 50 | S & F 18/19 mm thick, plywood, grade BWR, type BB, fixed with screws to timber frame work in partition/ cup baord/ wall panelling, etc complete all as specified and directed. |
| 51 | S & F 0.90 mm thick, Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed. |
| 52 | M & L for post construction Antitermite treatment Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 53 | M & L for post construction Antitermite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.complete all as specified and directed. |
| 54 | S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified in SSR Part I and directed. |
| 55 | S & F 25 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 455 gms) complete all as specified and directed. |
| 56 | M & L for moorum/red bajri filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 57 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 58 | S & F 110 mm bore, PVC (SWR), single socketed,Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 59 | S & F 75 mm bore, PVC (SWR), single socketed, Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed. |
| 60 | S & F 110 mm bore, PVC (SWR), single socketed, Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed. |
| 61 | S & F 75 mm bore, PVC (SWR), single socketed, Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed. |
| 62 | S & F 110 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed. |
| 63 | S & F 75 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed. |
| 64 | S & F 75 mm bore, PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. |
| 65 | S & F 110 mm bore, PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. |
| 66 | S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 67 | S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 68 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 69 | S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 70 | S & F 75 mm bore, PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and directed. |
| 71 | S & F 110 mm bore, PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and directed |
| 72 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in any type of soil complete all as specified and directed. |
| 73 | Removing excavated materials exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 74 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressingof sides and ramming of bottoms, lift upto 1.5 m,including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.. |
| 75 | M & L Reinforced concrete pipes, class NP3, 200 mm bore, laid and jointed with collars complete all as specified and as directed. |
| 76 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore drain pipes complete all as specified and directed . |
| 77 | M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 78 | M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately) |
| 79 | Excavation over areas, n.exc 1.5 m in depth and getting out in soft/loose soil complete as specified and directed. |
| 80 | M & L for designer Chequered cement concrete tiles of size 30cm x 30cm x 23-25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 81 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 82 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 83 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbishto a distance n.exe 100 m complete all as specified and directed. |
| 84 | M & L for 40 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 85 | M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 86 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish outside MD land as directed by the Engr-in-Charge. |
| 87 | M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed. |
| 88 | M & L for granite stone slab (of any type) as in vertical surfaces such as skirting/dado etc, 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick screed bed in cement mortor 1:4 & cutting, polishing complete all as specified and directed. |
| 89 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., and disposal of unserviceable materials, debris and rubbish to a distance exc 1.5 Km but not exc 5.00 Km complete as directed by the Engineer in Charge. complete all as specified and directed. |
| 90 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 91 | M&L for preparation of new platered surface of wall and applying two coats of weather proof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre, having dart pick up resistant, silicon enhanced, UV resistant and PU enhanced property over a coat of alkali resistant primer including all necessary scaffolding,complete all as specified and directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 92 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid/frame work etc complete all as specified and directed. |
| 93 | S & F aluminium Anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed by the Engr-in-Charge. |
| 94 | S&F ceiling with 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed by the Engineer-In-charge |
| 95 | M&L for preparation of new platered surface of ceiling and applying two coats of oil bound distemper over a coat of primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 96 | Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed. |
| 97 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 98 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed. |
| 99 | S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. |
| 100 | S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of neck 11 to15mm , length of bolt exc 5cm and n exc 10cm long complete all as specified and directed. |
| 101 | S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed. |
| 102 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 103 | S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter etc fixed with self tapping screws complete all as specified and directed. |
| 104 | M & L for Preparation of untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 105 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/disintegrated rock complete all as specified and directed. |
| 106 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 107 | M & L for 100mm thick plain cement concrete 1:4:8 type D- 2 using 40mm graded aggregate as in sub-base, floors and pavings etc complete all as specified and directed. |
| 108 | M&L for 100 mm thick cement concrete 1:2:4 type B- 2 using 40 mm grade aggregate as in base of flooring/hard standing, etc, and finishing the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. |
| 109 | M&L for Glass dividing strips, 3 mm thick and 38 mm width complete all as specified and directed. |
| 110 | M&L for Pre-cast cement concrete block masonry with solid blocks made out of PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) ,Grade 'C' masonry with compressive strength of 5N/sqmm, exc. 10 cm in width and setting in cemet mortar 1:6 complete complete all as specified and directed. |
| 111 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 112 | M&L for prepaqration of newly plastered wall surface and applying two coats of cement base paint over a coat of alkali resistance primer complete all as specified and directed. |
| 113 | M & L for Mild Steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® complete all as specified and directed. |
| 114 | Supply, laying, connection and testing, 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 115 | Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 116 | S & F 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 117 | S & F 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 118 | Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area exc 400 sq.cm but n.exc 0.1 Sqm complete all as specified and directed. Please Enable Macros to View BoQ information |
| 119 | Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area exc 400 sq.cm but n.exc 0.1 Sqm complete all as specified and directed. Please Enable Macros to View BoQ information |