Tender For Name Of Work : Name Of Work:Upgradation Of Roads Infrastructure In Bhuj Mil Stn
Tender Overview
Project Description
Tender for Name Of Work : Name Of Work:Upgradation Of Roads Infrastructure In Bhuj Mil Stn
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Jul-2026 | Corrigendum No 01 | Date | 04-Aug-2026 |
| 2 | 28-Jul-2026 | Corrigendum No 02 | Date | 17-Aug-2026 |
| 3 | 17-Aug-2026 | Corrigendum No 05 | Date | 31-Aug-2026 |
| 4 | 07-Aug-2026 | Corrigendum No 04 | Date | 24-Aug-2026 |
| 5 | 06-Aug-2026 | Corrigendum No 03 | BOQ | 24-Aug-2026 |
| 6 | 06-Aug-2026 | Corrigendum No 03 | Other | 24-Aug-2026 |
| 7 | 20-Aug-2026 | Corrigendum No 06 | Other | 07-Sep-2026 |
| 8 | 24-Aug-2026 | Corrigendum No 07 | Date | 07-Sep-2026 |
| 9 | 20-Aug-2026 | Corrigendum No 06 | BOQ | 07-Sep-2026 |
| 10 | 31-Aug-2026 | Corrigendum No 08 | Date | 14-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exc 30cm deep and an averaging 15cm deep and getting out in soft/loose soil all as specified and directed by engineer-in-charge. |
| 2 | Rough excavationnot exc 1.5 m deep not exc 3.0 m, and getting out in soft and loose soil complete all as specified and directed by engineer-in-charge. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outall in soft/loose soil all as specified and directed by engineer-in-charge. |
| 4 | Excavating in trenches, n exc 1.5 m wide ,exc 1.5 m depth but n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outall in soft/loose soil all as specified and directed by engineer-in-charge. |
| 5 | Earth work in excavation in all kind soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m all as specified and directed by engineer-in-charge. |
| 6 | Excavating in trenches in all kind of soil by mechanical means (Hydraulic excavator) n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m completeall as specified and directed by engineer-in-charge. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming excavated soil in layers not exc 25cm thick in soil complete all as specified and directed by engineer-in-charge. |
| 8 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape,etc., exc. 1.5 m high not exc 3 m high from base complete all as specified and directed by engineer-in-charge. |
| 9 | M&L for approved earth filling obtained from outside defence land, laid in layers n.exc 15 cm thick, spread, levelled including watering all as specified and directed by engineer-in-charge. |
| 10 | Removing excavated material (soil) to a distance not exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by engineer-in-charge. |
| 11 | Removing excavated material (soil) to a distance exc 50 Mtr but not exc 100 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by engineer-in-charge. |
| 12 | Removing excavated material (soil) exc 250 Mtr but not exc 500 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by engineer-in-charge. |
| 13 | Removing excavated material (soil) to a distanceexc 1.5 km but not exc 5.0 km and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by engineer-in-charge. |
| 14 | Supply & laying Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by engineer-in-charge. |
| 15 | M & L for hardcore of gauge not exceeding 63 mm of broken stones and boulders deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed by engineer-in-charge. |
| 16 | Rolling and consolidation to required gradient and camber formation surfaces (cutting or filling) of roads using 8 to 12 tonne power roller including filling in depression which occur during rolling(incl berm) complete all as specified and directed by engineer-in-charge. |
| 17 | M & L for Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per Grade I as specified Table 400-1 of MORTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed by engineer-in-charge. |
| 18 | M & L for laying and compacting 150 mm thick (compacted thickness) WMM(Wet Mix Macadam) laidin two layer of 75 mm each Confirming to grading given in table 400-13 of morth specification for road and bridge work 2013 manufactured in WMM plant material comprising of clean crushed graded aggrigate and grainular materials premixed with water to dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required and directed. The finished surface tollerence to be as per table 900-1 MORT&H specificationfor road and bridge work 2013 complete all as specified and directed by engineer-in-charge.Note:- 02 Layers shall be considered one unit. |
| 19 | M&L for preparing un-surfaced WMM surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surfaces with compressed air to remove all loose complete all as specified and directed by engineer-in-charge. |
| 20 | M & L for applying applying evenly a priming/tack coat of VG-10 grade paving bituminous primer at 10 kg per 10 sq metre with machanical spray complete all as specified and directed by engineer-in-charge. |
| 21 | Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exceeding 400 sqm, depth of pot hole exceeding 50 mm but not exceeding 100 mm including rolling over the broken surfaces using 8 to 10 tonnes power roller to required camber and gradient complete all as specified and directed by engineer-in-charge. |
| 22 | M&L for premix bituminous macadam (BM) 50 mm thick for grading 2 as given in Table 500-10 on page No 177 of MORTH with 4.5% binder content (VG-40) by weight of total mix with rock dust filler 2% as per design mix using mechanical paver with string sensor with Marshal stability 9.0 KN at 60 degree C, laid to required gradient and camber complete all as specified and directed by engineer-in-charge.Note :-Job mix foumula for Item No 22 shall be Carried out as per SSR and as specified hereinafter. |
| 23 | M & L for preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned sirfaces with gunny bags to remove all loose dirt etc applying applying evenly a priming/tack coat of VG-10 grade paving bituminous primer at 5 kg per 10 sq metre with machanical spray complete all as specified and directed by engineer-in-charge. |
| 24 | M&L for laying 40 mm thick (consolidated thickness) bituminous premixed semi dense asphaltic concrete with 5.5% binder content by weight of total mix using paving bitumen (VG-40), mixed in hot mix plant, laid with mechanical paver, rolled and compacted to required camber and gradient with 8 to 12 tonne power roller all as specified and directed by Engineer-in-Charge.Note: - Job mix foumula for Item No 24 shall be Carried out as per SSR and as specified hereinafter. |
| 25 | M&L for laying 30 mm thick (consolidated thickness) bituminous premixed semi dense asphaltic concrete with 5.5% binder content by weight of total mix using paving bitumen (VG-40), mixed in hot mix plant, laid with mechanical paver, rolled and compacted to required camber and gradient with 8 to 12 tonne power roller all as specified and directed by Engineer-in-Charge.Note: - Job mix foumula for Item No 25 shall be Carried out as per SSR and as specified hereinafter. |
| 26 | M & L for preparing bituminous surfaces of road and applying road marking paint 2.5 mm thick width n exc. 15 cm with hot applied thermoplastic road marking paint like stop lines, dashes, arrows etc of approved colour conforming to BS 3262-1989 with 20% glass beads (intermixed) spread and laid by automatic mechanical machine engine at approx temprature of 160 degree celcius with special applicator machine all as per manufacturer's instructions complete all as specified and directed by engineer-in-charge. |
| 27 | Supply and fixing metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and directed by engineer-in-charge. |
| 28 | Supply and fixing cat eye reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and directed by engineer-in-charge. |
| 29 | Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed by engineer-in-charge. |
| 30 | S&F in repair Solar Delinators of 1000x47mm made of polycarbonate and toughened aluminium body height 145mm, diameter 80mm comprises of 4 super LEDs which give 360 degree viewing, solar panel - 2.5V, 120mm (approx) 1.25V rechargeable battery-1No and mounted on MS Pipe of 50mm duly powder coated , anti theft steel net of size 700mmx50mmx100mm incl removal of existing complete all as specified and directed by Engr in Charge (Note:- Excavation for bed block of size 150x150x200mm filling with concrete 1:3:6 and clearing of the area shall be included in the rate quoted) |
| 31 | S &F Convex curved polished stainless steel mirror on road of dia 600mm ,viewing distance min 15 mtr, curvature view angle 130-160 degreewith mounting hardware as galvanized steel poles of dia 60-70mm pole with backing material as acrylonitrile butadiene styrene, polypropylene, or galvanized steel typiycally finished in highly visible orange safety color with weather proof seal all as speceified and directed by engineer in charge incl taking down the existing all as specified and directed by engineer-in-charge. (Note:- Excavation for bed block of size 150x150x200mm filling with concrete 1:3:6 and clearing of the area shall be included in the rate quoted) |
| 32 | Manufacturing, supplying and fixing Retroreflective regulatory sign board of size 900 mm dia made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete all as specified and directed by engineer-in-charge. |
| 33 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required all as specified and directed by engineer-in-charge. |
| 34 | M&L for PCC (1:3:6) type B-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed by engineer-in-charge. |
| 35 | M&L for PCC (1:4:8)) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed by engineer-in-charge. |
| 36 | M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and directed by engineer-in-charge. |
| 37 | M&L for PCC 1:2:4 type B-2 using 40 mm graded aggregates for surface channel including weathering slightly rounded or chamfered including formwork complete all as specified and directed. including necessary form work complete all as specified and directed by engineer-in-charge. |
| 38 | M&L for cement concrete 1:4:8, type D-2 (40mm crushed graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed by engineer-in-charge. |
| 39 | M&L for cement concrete 1:2:4, type B-0 (12.5mm crushed graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed by engineer-in-charge. |
| 40 | M&L for cement concrete Type C-1 1:2:4 (20mm graded agg) as in coping, bed block and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed by engineer-in-charge. |
| 41 | M&L for Walling of random rubble, uncoursed, well bonded,bedded and solidly hearted lin retaining walls, abutments and similar work built in CM 1:6 complete all as specified and directed by engineer-in-charge. |
| 42 | M & L Boulder pitching, laid dry,grouted with cement sand mortor 1:4 complete all as specified and directed by engineer-in-charge. |
| 43 | M & L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed exc 10 cm in width and set and jointed in C M 1:6 complete all as specified and directed by engineer-in-charge. |
| 44 | M&L Reinforced cement concrete M-30 (design mix), using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by engineer-in-charge. |
| 45 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work exceeding 200mm thick complete all as specified and directed by engineer-in-charge. |
| 46 | Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete , using extra cement, including forming moulds, mitered/stopped ends etc. complete all as specified and directed by engineer-in-charge. |
| 47 | M&L for rendering 10mm thick on fair face of block masonary in CM 1:4 and finishing even and smooth without using extra cement complete all as specified and directed by engineer-in-charge. |
| 48 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed by engineer-in-charge. |
| 49 | M&L for prepartion of new surfaces of walls and applying two coat of Cemenet Base Paint complete all as specified and directed by engineer-in-charge. |
| 50 | M & L for reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by engineer-in-charge. |
| 51 | M & L 100 mm thick plain cement concrete type D-2 1;4:8 (Using 40 mm grade stone aggregate ) as in sub base complete all as specified and as directed by Engr-in-charge. |
| 52 | S&F Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by Engr-in-charge. |
| 53 | S&F Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engr-in-charge. |
| 54 | S&F PVC (SWR) pipes 110 mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in-charge. |
| 55 | M&Lfor preparation of new or previously untreated surfaces of concrete over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by Engr-in-charge. |
| 56 | M&L TMT bars 10mm dia and over, cut to Length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-charge. |
| 57 | M&L TMT bars 6 to 8 mm dia and over, cut to Length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-charge. |
| 58 | S&F Prestressed concrete poles of 9 meter long having 102 mm x 152 mm at top and 102 mm x 289 mm at bottom,class 10,complete all as specified and directed by engineer-in-charge. |
| 59 | S&F LED Security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic external driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT3000-6000 CRI greater than 70, input power 70 W system with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistranded copper conductor sheathed cable of size 1.0 SQMM fixed with complete all as specified and directed by engineer-in-charge. |
| 60 | Supply and fix in repairs Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers etc. complete all as specified and directed by engineer-in-charge. |
| 61 | Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm 3 core 1100 volts grade in PVC conduit pipe completeall as specified and directed by engineer-in-charge. |
| 62 | Supply, laying and testing cable XLPE insulated, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium, 1100 volts grade (Earthed)complete all as specified and directed by engineer-in-charge., of following size:- |
| 63 | 2 core 10 sqmm |
| 64 | 4 core 16 sqmm |
| 65 | 4 core 25 sqmm |
| 66 | 3.5 core 35 sqmm |
| 67 | 3.5 core 50 sqmm |
| 68 | 3.5 core 70 sqmm |
| 69 | 3.5 core 95 sqmm |
| 70 | 3.5 core 150 sqmm |
| 71 | 3.5 core 185 sqmm |
| 72 | 3.5 core 240 sqmm |
| 73 | Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as all as specified and directed by engineer-in-charge.. Note :- Only compacted thickness of sand will be measured and paid separately. |
| 74 | Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed by engineer-in-charge. |
| 75 | S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and completeall as specified and directed by engineer-in-charge. for cable protection . |
| 76 | S & F GI pipe, light grade, of size 80 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and complete all as specified and directed by engineer-in-charge for cable protection . |
| 77 | S & F GI pipe, light grade, of size 100 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and complete all as specified and directed by engineer-in-charge for cable protection . |
| 78 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mps working pressure,complete all as specified and directed by engineer-in-charge. |
| 79 | Supply and fixing Digital street light timer panel, outdoor type IP 54 digital programmable timer control street light auto ON-OFF , for single or three phase load of maximum capacity 5 KW,timer panel should consite of 4 pole MCBsof suitable 32 Amp capacity, 3 pole Power Contactor AC-3 of 32A ,SP circuit break -1 no's and Enclosure for encasing above compnents complete all fixing to pole with GI strips complete all as specified and directed by engineer-in-charge. |
| 80 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 750amps (b) MCCB 4 Pole thermal magnetic release 415 volts 500 A 36 KA,Ics=100%Icu -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 250 A, 36 KA,Ics=100%Icu -02 Nos ( Adm Block LT panel+spare ) (outgoing)(d) MCCB 4 pole thermal magnetic release 160 A, 36 KA ,Ics=100%Icu -01 Nos (MLI pump house ) ( outgoing)(e) MCCB 4 pole thermal magnetic release 63 A, 16 KA ,Ics=100%Icu ,-04 Nos (MI room, mandir, store-2 nos) ( Outgoing)(f) Digital street light timer with TPN MCB of 32A , 40A contactor, and all connected items all as specfied and directed-01 Nos. |
| 81 | (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: MLI pump house main LT panel |
| 82 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 500 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 415 volts 160 A, 36 KA,Ics=100%Icu -02 Nos ( Cook house over head line+spare ) (outgoing)(d) MCCB 4 pole thermal magnetic release415 volts 100 A, 16 KA ,Ics=100%Icu -01 Nos (Adm block) ( outgoing)(e) MCCB 4 pole thermal magnetic release 415 volts 63 A, 16 KA ,Ics=100%Icu ,-03 Nos (Qtr guard, big store &existing OR over head line) ( Outgoing)(f) MCCB 4 pole thermal magnetic release 415 volts 40 A, 16 KA ,Ics=100%Icu ,-02 Nos (Small store & sentry) ( Outgoing) |
| 83 | (g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (h) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(j) Ammeter digital type 0-500 A with in built selector switch and CTs-01 No(k)Digital Timer system with incoming TPN , contactor, timer and connected items -01 NosLocation: MLI pump house to LT Panel 1 near Adm block |
| 84 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 300 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 200 A 36 KA,Ics=100%Icu -01Nos (incoming), (c)MCCB 4 Pole thermal magnetic release 415 volts 160 A 36 KA,Ics=100%Icu -02 Nos (JCO mess panel+spare), (Outgoing)(d) MCCB 4 pole thermal magnetic release 415 Volts 100 A, 16 KA, Ics=100%Icu -01Nos (Over head LT line ) (Outgoing)(e) MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA, Ics=100%Icu ,-01 Nos (store ) (Outgoing)(f) Digital street light timer with TPN MCB of 32A , 40A contactor, and all connected items all as specfied and directed.-01 Nos |
| 85 | (g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (h) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(j) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: 2 Gadwal Main LT panel |
| 86 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 240 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 160 A 36 KA,Ics=100%Icu -01Nos (incoming), (c)MCCB 4 Pole thermal magnetic release 415 volts 63 A 16 KA,Ics=100%Icu -02 Nos (working+spare), (Outgoing)(d)MCB 2 pole SPN 32A-6 Nos (Outgoing)(e) Digital street light timer with TPN MCB of 32A , 40A contactor, and all connected items all as specfied and directed- 01 Nos |
| 87 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation:2 Gadwal sub LT panel near JCO mess |
| 88 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 500 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 320 A 36 KA,Ics=100%Icu -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 415 Volts 160 A, 36 KA, Ics=100%Icu , -03 Nos ( Off Adm Accn, JCO mess, spare )(Outgoing)(d)MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA, Ics=100%Icu -02 Nos (cook house ) (Outgoing)(e) Digital street light timer with TPN MCB of 32A , 40A contactor, and all connected items all as specfied and directed- 01 Nos |
| 89 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: Main LT panel near 2075 Field Hospital Transformer |
| 90 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 240 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 160 A 36 KA,Ics=100%Icu , -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA, Ics=100%Icu -03 Nos ( Off Adm Accn-2 nos+spare ) (Outgoing)(d)MCCB 4 pole thermal magnetic release 415 Volts 40 A, 16 KA, Ics=100%Icu -03 Nos (OR Lines 03 nos ) (Outgoing)(e) SPN 32 A-2 Nos (Outgoing) |
| 91 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: 2075 field hospital LT panel-1 near Adm block |
| 92 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 240 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 160 A 36 KA,Ics=100%Icu , -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 415 Volts 100 A, 16 KA, Ics=100%Icu -02 Nos ( Jcos living+spare ) (Outgoing)(d)MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA, Ics=100%Icu -03 Nos (OR mess, MT repair bay,JCO mess ) (Outgoing)( e) 240V SPN 32 A -4 Nos (Outgoing) |
| 93 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: Main LT panel near 2075 field hospital transformer to LT panel-2 nearJCO block |
| 94 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 600 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 400 A 36 KA,Ics=100%Icu -01 Nos (incoming), (c)MCCB 4 pole thermal magnetic release 415 Volts 200 A, 36 KA, Ics=100%Icu ,-02 Nos (OR LT panel+spare ) (Outgoing)(d)MCCB 4 pole thermal magnetic release 415 Volts 200 A, 36 KA, Ics=100%Icu ,-02 Nos (OR LT panel+spare ) (Outgoing)(e)MCCB 4 pole thermal magnetic release 415 Volts 40 A, 16 KA, Ics=100%Icu -07 Nos (Outgoing)(f) Digital street light timer with TPN MCB of 32A , 40A contactor, and all connected items all as specfied and directed- 01 Nos |
| 95 | (g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (h) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(j) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: Transformer Main LT panel near 23 JAT cook house |
| 96 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 300 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 200 A 36KA,Ics=100%Icu ,-01(incoming), (c)MCCB 4 pole thermal magnetic release 415 Volts 40 A, 16 KA, Ics=100%Icu ,-5 Nos (04 working+spare) (Outgoing)(d)MCB SPN 32 A -6 Nos (Outgoing) |
| 97 | (e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (f) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(g) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: LT panel near 23 JAT OR line |
| 98 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 100 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 40 A 16 KA,Ics=100%Icu -01 Nos (incoming), (c) MCCB 4 pole thermal magnetic release 415 Volts 25 A, 16 KA, Ics=100%Icu -2 Nos (01 working+spare) (outgoing)(d) MCB SPN 32 A -6 Nos (outgoing) |
| 99 | (e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (f) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(g) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: LT panel near 23 JAT BN store |
| 100 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper bus bar or copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation , including MS Angle Frame of size 50x50x6 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-(a) copper Bus bar of capacity 150 amps (b) MCCB 4 Pole thermal magnetic release 415 volts 100 A 16 KA,Ics=100%Icu -01 Nos (incoming), (c) MCCB 4 pole thermal magnetic release 415 Volts 25 A, 16 KA, Ics=100%Icu ,-2 Nos (01 working+spare) (Outgoing)(d) MCB SPN 10 A -10 Nos (outgoing) |
| 101 | (e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (f) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No(g) Ammeter digital type 0-500 A with in built selector switch and CTs-01 NoLocation: LT panel near 23 JAT MT area |
| 102 | S&F PVC pipe 15 mm light grade with all fitting to cable junction box to street light fitting for cable protection with suitable size clamp, nut bolt and washers complete all as specified and directed by engineer-in-charge. |
| 103 | Material and labour for Cross arms, bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint. Complete all as specified and directed by engineer-in-charge. |
| 104 | Supply and fix All aluminium conductor having high strength to weight ratio for jumper of 2/4 pole structure complete all as specified and directed by engineer-in-charge. |
| 105 | M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron lead of 4 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified and directed by engineer-in-charge.NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ |
| 106 | Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below normal ground level) connected to galvanized iron earth strip of dia 32 mm x 6 mm as earthing lead means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12 mm dia round bar handle. Complete all as specified and directed by engineer-in-charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/ protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’. |
| 107 | Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32×6mm dia galvanised steel strip all as specified and directed by engineer-in-charge. |
| 108 | Taking down existing PCC pole of 9 mtrs carefully from site without damaging existing infrstructure all as specified and directed by engineer-in-charge. |
| 109 | Taking down existing ACSR conductor including any type carefully all as specified and directed by engineer-in-charge. |
| 110 | Taking down existing street light timer panel including disconnection of incoming/outgoing cable carefully from site all as specified and directed by engineer-in-charge. |
| 111 | Taking down existing pin /disc insulator of any size carefully all as specified and directed by engineer-in-charge. |
| 112 | Taking down existing cross arms of any size and type carefully from site all as specified and directed by engineer-in-charge. |
| 113 | Taking down XLPE cable of any size and type including disconnection of incoming/outgoing cable carefully from site all as specified and directed by engineer-in-charge. |
| 114 | Taking down junction box of any size and type including disconnection of incoming/outgoing cable carefully from site all as specified and directed by engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-8 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-9 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-10 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 12 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender